background image

Serious injury might result if the following precautions are not followed.

The user may be injured or there would be property damage if the instructions below are not followed.

 The installation should be performed by certified workers under the relevant regulations of end user's 

   country / region. 

 Never modify or disassemble LED lighting arbitrarily because it can cause serious accidents.

 Never use any input power except the listed rated voltage. If not, it can cause serious accidents.

 Before installation, shut off the power supply and verify it is de-powered using a measuring instrument.

 The wiring should be insulated under end user's respective region's Electric Installations Standards.

 Do not install in a wet environment. 

This symbol is intended to remind the user the presence of actions and operation that may cause danger.
Please read instructions carefully and follow the instructions to avoid any danger.

This symbol is intended to represent precautions that the user should follow to prevent danger.

 Do not forcefully pull on AC/DC lines when wiring up the lighting. (It causes the wires to snap.)

 Do not use this product for any purposes other than what’s specified. 

The manufacturer or sellers are not responsible for breakdowns or accidents caused by its improper use.

 When connecting the wires, use proper connection terminals depending on the site of installation. 

   Do not install in a wet environment.

 Make sure to ground fixture by contacting it to metals around it to prevent damage by static.

 The product may be damaged if static is not removed.

 During the operation, be careful not to disconnect the wires. 

 Make sure the grounding is performed under Electricity Standards.

 Using it for any voltage other than specified can cause failure or fire.

 Do not use it in moist environment. 

 Be mindful of proper ventilation of product.

 Improper installation or disassembly causes a deformation or breakdown of the product. 

 Consider proper protection devices, such as circuit breakers, fuses, switches, etc. for safety precautions.

 Do not install in an enviroment with excessive vibration.

 Do not handle product with contaminated hands or gloves.

 In any event, do not store / install in a contaminated place.

 Changes or modifications not expressly approved by the manufacturer could void the user's authority to

   operate the equipment.

 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

   to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful     
   interference in a residential installation. This equipment generates, uses and can radiate radio frequency 
   energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
   to radio communications. However, there is no guarantee that interference will not occur in a particular
   installation.

 If this equipment does cause harmful interference to radio or television reception, which can be

   determined by turning the equipment off and on, the user is encouraged to try to correct the interference 
   by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

WA

RNI

NG

CAUTION

Safety Precautions Installation

Summary of Contents for HR 110W

Page 1: ...HR R 85W 110W 150W Product Installation Operation User Guide http www kmwgigatera com Installation Operation User Guide Roadway Lighting LED...

Page 2: ...ires Make sure the grounding is performed under Electricity Standards Using it for any voltage other than specified can cause failure or fire Do not use it in moist environment Be mindful of proper ve...

Page 3: ...nts 1 Vertically Arranged LED Module Method HR adopted vertically arranged LED moduled unlike existing streetlamps The vertically arranged LED mod ules can help to minimize the heat generating from th...

Page 4: ...the assumption an Electronic Auto Switch is installed to each product A product with an Electronic Auto Switch may look different from what it looks like in the brochure Although the other parts than...

Page 5: ...1 2012 KMW INC All Rights Reserved 5 Document Revision V0 61 2013 01 15 Pages R Street Light HR Installation Operation User Guide HR Converter Detail Description No Item Purpose HR LED Streetlamp Conv...

Page 6: ...Pages R Street Light HR Installation Operation User Guide Illumination Sensor Intensity Detail Description No Item Purpose HR LED Streetlamp Converter Lamp and Brightness Sensor Power Supply Device SM...

Page 7: ...Operation User Guide HR DCM Converter Package 3 Built In DCM Type Dimming Control Once installed the DCM module will be synchronized with the LCS system for illumination control to enable the dimming...

Page 8: ...ail Description No Item Purpose HR LED Streetlamp Converter Lamp and Brightness Sensor Power Supply Device SMPS DCM Data Control Module LCS Controllwe is not included Illumination Sensor In tensity Su...

Page 9: ...ke sure the cutter blade doesn t enter deep enough to scratch the product surface Also be careful not to hurt yourself Once the box is open you will see a package fully covering the product Open the t...

Page 10: ...he following figure If you don t use the Electronic Auto Switch skip the above step and jump to Step 10 Swing the receptacle horizontally and set it as close as to the north on the basis of the arrow...

Page 11: ...tion against the direction nature may damage the lamp connection part The brightness sensor is optional and it may look different from what it looks like in the figure if it is bought by the user Alig...

Page 12: ...w er cable wiring To begin with use your thumb to push the latch lock er upward and pull the lower part like the following figure When you zoom in the image the part that was hid den for easier descri...

Page 13: ...tion User Guide Open the SMPS part and hang it on the hook before you start wiring InserttheACpowercablebehindthearmlikethefol lowing figure HR Model basically does not supply the AC power cable If ne...

Page 14: ...bond them together Attach the lamp to the light pole like the fol lowing figure Once the lamp is installed use fixing bolts to fix it to the light pole When you remove the cap on top of the lamp as il...

Page 15: ...t the time of power supply Use the twister to connect the two cores of the black cable N with each other like the following figure Each cable comes from the core after it is connected to the AC power...

Page 16: ...o control the lighting sur face by 5 in vertical direction Please remember the default of the product is set to 0 when it is shipped out from the factory Do not disassemble the fixing bolt for angle s...

Page 17: ...ng aligning its first and third bolt holes with the corresponding light pole holes and bolt parts together for fixing like the following figure Put the bolts through the points where both holes are al...

Page 18: ...ing RF LED Provider 1521 E Orangethorpe Ave Ste A Fullerton CA 92831 U S A 183 6 Yeongcheon ro Dongtan myeon Hwaseong si Gyeonggi do Korea 1 714 515 1100 sales kmwgigatera com 82 31 370 8720 chriskim...

Reviews: