NEBS Level 3 Compliance
This appendix provides installation instructions for GigaVUE TA Series-TA10, GigaVUE TA
Series-TA40, GigaVUE TA Series-TA100, and GigaVUE TA Series-TA200 Network
Equipment-Building System (NEBS) Level 3 compliance.
Installation Instructions GigaVUE TA Series-TA10,
TA40, TA100, TA200
The following sections detail installation instructions for GigaVUE TA Series-TA10,
GigaVUE TA Series-TA40, GigaVUE TA Series-TA100, and GigaVUE TA Series-TA200.
Topics:
Intrabuilding or Intra-connection for GigaVUE TA
Series-TA10
WARNING: The intra-building ports:
• RJ45: Management port, Console port
• 1G/10G SFP/SFP+: X1 - X48
• 40G QSFP+: Q1-Q4
GigaVUE TA Series-TA10 equipment or subassembly are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the
equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and
require isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP wiring.
Intrabuilding or Intra-connection for GigaVUE TA
Series-TA40
WARNING: The intra-building ports:
• RJ45: Management port, Console port
• 40G QSFP+: Q1-Q32