2.  APPLICATION

Economic Rack Mount IP terminal with built-in amplifier, widely installed in weak-current rooms or 

branch control room for public address, built-in amplifier, used for hall, corridor and outdoor areas for 

program broadcasting and local public address.

3.  FEATURES

01.  Standard 19’’ rack design, black aluminum panel, professional mechanical assembly process, high-

end appearance.

02.  Industrial grade 3.4-inch LCD, it can clearly show the majority of dot pattern and machine work 

status; equipped with infrared remote control, on-demand broadcast all contents in server library, 

can control the playback / pause, flexible and simple operation.

03.  Using embedded computer and DSP audio processing technology, high-speed industrial-grade 

SCM system chip, start time is less than 1s.

04.  Built-in 1 network hardware audio decoding module, support TCP / IP, UDP, IGMP (multicast proto-

col), to achieve network transmission 16-bit CD audio quality audio signal.

05.  Built-in high-fidelity analog amplifier, with 8-zone independent control, and 120 W / 240 W / 350 W 

/ 500 W options of 100 V output. Its 1~8 zone output interfaces make it supports to call any zone (or 

zone group), supports to call all zones, and also supports to configure a zone (or zone group) to per-

form timing tasks at specific time period .Besides, it supports alarm task, to play preset audio in the 

preset linkage zone (or zone group), to play real-time file in any zone (or zone group) , to make the 

terminal to collect real-time audio of any zone (or zone group). The output interface is 100V based, 

can be used to connect 100V constant voltage speakers.

06.  1 line (AUX) and 1 microphone (MIC) input interface, with independent volume control and treble/

bass control, support local paging function in off-line status.

07.  1 channel EMC input interface, the emergency audio signal is direct connected, with the highest 

priority.

08.  2-channel audio signal auxiliary output interface, can connect with external amplifier; the standard 

RCA interface makes it easy to connect the cables.

09.  Built-in intelligent power management module, when there is no BGM or paging tasks, it will auto-

matically cut off the power of amplifier. When signal cones,it will automatically turn on the power. 

It supports software programming to pre-open the power of amplifier.

10. Built-in 3 priority settings:
  - EMC has the highest priority.
  - The network alarm signal has higher priority than MIC, AUX and network background music signals.
  - MIC has higher priority than AUX and network background music signals.
  - AUX and network background music has the same level priority.
11.  Support preset mute level reducing function, preset background accompaniment function; it has 

indicators to display the system status, including level indicator, protection indicator, standby indi-

cator, etc. The standby power consumption is less than 3W.

12.  Compatible with routers, switches, bridge gateway, Modem, Internet, 2G, 3G, 4G, multicast, unicast 

and any other network structure.

13.  Digitalized products, easy expansion, not limited by geographical location, no need to increase the 

control room management equipment, easy to install.

Summary of Contents for GGM IPAP8 Series

Page 1: ...GGM IPAP8240 GGM IPAP8350 GGM IPAP8500 USER MANUAL www gigamedia net Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference ...

Page 2: ... the treatment and recycling of used batteries you can return them to your dealer deposit them in a collection bin provided for this purpose or return them to your municipal waste which is obliged to recover them WEEE regulation This product is covered by the WEEE II Directive Directive 2012 19 EU It should not be thrown in the trash or dumped Substances in the product may be hazardous to human he...

Page 3: ...cluding the unit itself on the power cord as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is ap plied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth ter minal to avoid electric shock Never ground to a gas pipe as a catastrophic di...

Page 4: ... near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or elec tric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to...

Page 5: ... group to make the terminal to collect real time audio of any zone or zone group The output interface is 100V based can be used to connect 100V constant voltage speakers 06 1 line AUX and 1 microphone MIC input interface with independent volume control and treble bass control support local paging function in off line status 07 1 channel EMC input interface the emergency audio signal is direct conn...

Page 6: ...icator 10 FINE status indicator 11 IR infrared receiving window 12 TREBLE treble adjust the response of treble Increase treble output by knob clockwise rotation and decrease it by knob anticlockwise rotation 13 BASS bass adjust the response of bass Increase bass output by knob clockwise rotation and decrease it by knob anticlockwise rotation FRONT PANEL 2U FRONT PANEL 3U MIC ON OFF IP TERMINAL WIT...

Page 7: ...100 V which can connect to speaker with constant voltage 100 V 03 Mute potentiometer turn the knob to the rightmost the mute level is the maximum and turn the knob to the leftmost the mute is the minimum 04 Line input interface 05 EMC input interface 06 Line output interface 07 RJ45 network interface connecting with the internet of PC host Ethernet switch 08 Cooling fan REAR PANEL 2U REAR PANEL 3U...

Page 8: ...en you will have to press the button Inquire Figure 1 to display the equipments found by iptool Figure 2 You will now have to change the IP address of your equipment to match the IP addresses of your network You need to fill every field below New terminal Figure 3 Once all the fields are filled press the button Write to apply the configuration and check with the button Ping to see if it is reachab...

Page 9: ..._ ZONE 3 _ ZONE 4 _ ZONE 8 _ MUTE 100V 230V 50Hz 180W T3 15AL 250V OPEN CLOSE PLAY STOP NEXT PREVIOUS ON OFF POWER VOL PLAY MSG MIC in PLAY SIREN REC in ON OFF STANDBY PLAY ALARM MODE RECORD STOP START ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL ZONE 1 ZONE 2 ZONE 8 CD MP3 player Alarming signal generator Power amplifier Ethernet switch ...

Page 10: ...IN OUT LINE LAN IN MUTE 100V 230V 50Hz 750W T8AL 250V ZONE 1 ZONE 2 ZONE 8 OPEN CLOSE PLAY STOP NEXT PREVIOUS ON OFF POWER VOL PLAY MSG MIC in PLAY SIREN REC in ON OFF STANDBY PLAY ALARM MODE RECORD STOP START ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL CD MP3 player Alarming signal generator Power amplifier Ethernet switch ...

Page 11: ...2 RCA output AUX output impedance 470 Ω Treble adjustment range 10 dB Bass adjustment range 10 dB Rated power 120 W 240 W 350 W 500 W Power consumption 180 W 370 W 540 W 750 W Standby power consumption 3 W Frequency response 80 Hz 16 kHz 1 dB 3 dB THD THD 1 SNR 65 dB Output method 100 V constant voltage output Circuit protection DC output overload over temperature short circuit protection Operatio...

Reviews: