GIGAMEDIA GGM IPAI1 Owner'S Manual Download Page 4

 SAFETY PRECAUTIONS

4

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

    Never  plug  in  nor remove the power  supply  plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

    When unplugging  the  power  supply cord, be sure
    to grasp the  power  supply  plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

    When moving the unit, be sure to remove its power 
    supply cord  from the  wall  outlet.  Moving  the unit
    with the  power  cord  connected  to  the outlet may
    cause damage to the power cord, resulting in fire or 
    electric shock. When  removing the power cord,  be
    sure to hold its plug to pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating  sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

    Do not place heavy objects on the unit as  this  may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
    Loud noise produced at high volume when power is 
    switched  on  can  impair  hearing.

    Do not operate  the  unit  for an  extended  period of 
    time with  the sound distorting. This  is  an indication
    of  a  malfunction,  which  in  turn  can cause heat to
    generate and result in a fire.

    Contact  your  dealer  as  to  the  cleaning. If  dust
    is  allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

  If dust accumulates on the power supply plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off  the  power, and unplug the power  supply
  plug  from the  AC outlet  for  safety  purposes when 
  cleaning  or  leaving the unit unused for  10  days or 
  more. Doing otherwise  may cause a fire  or  electric 
  shock.

WWW.GIGAMEDIA.NET

Summary of Contents for GGM IPAI1

Page 1: ...uctions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference IP NETWORK PA SYSTEM WWW GIGAMEDIA NET GGM IPAI1 NETWORK AUDIO ADAPTER OWNER S MANUAL ...

Page 2: ...3 5 4 6 4 1 Front panel 6 4 2 Wiring diagram 6 7 6 9 10 11 SAFETY PRECAUTIONS APPLICATION FEATURES NOMENCLATURE AND FUNCTIONS 5 OPERATION BLOCK DIAGRAM 7 SPECIFICATIONS 8 BOTTOM CASE INSTALLATION DIMENSION FIGURE WWW GIGAMEDIA NET ...

Page 3: ...doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting ...

Page 4: ...ions generating sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power...

Page 5: ...e quick link simple operation 4 Built in 2W High fidelity full frequency speaker clear and loud phone voice 5 Built in high sensitive mic wide area voice collecting and high sound reproduction 6 Support hands free calls and receive broadcast 7 One way audio output external expansion power amplifier 8 One way short circuit input can be used as a trigger preset voice prompt or alarm 9 One way alarm ...

Page 6: ... when network connection is normal 3 When intercom call waiting light A is available flashing green light 500 ms each 4 Intercom connected indicator light A B is effective at the same time bright orange light 3 Speaker output When one key to seek help call or play background music network signal there is voice output for speaker 4 2 Wiring diagram Anti disassembly switch DC 24V input internet acce...

Page 7: ...odify current terminal IP address can be manually directly change the dialogue window IP address item or directly press next button on the basis of the current existing IP address ascending order as shown in figure 3 After set up the relevant parameters click on write button then press the PING button check the IP address of the new modified with terminal server if it is connected the pop up windo...

Page 8: ...akers will be each other s voice 4 When playing the music in the IP network broadcast file in the speaker and the LINE OUT it will have the background music output of the network 5 Connected electric door lock when the door is opening or closing it will trigger a short circuit signal input to the SHORT IN terminal 6 Short circuit output function has two kinds of short circuit output trigger mode i...

Page 9: ...t Network board 5V Power Conditioner 5V Power Conditioner Network signal buffer amplifier Power amplifier 3W Power amplifier MIC amplifier Compressor processing MIC amplifier MIC compressor processing 4Ω 6 BLOCK DIAGRAM 9 WWW GIGAMEDIA NET ...

Page 10: ... bit stereo CD tone quality THD 1 80Hz 16KHz 1dB 3dB 70dB TCP IP UDP IGMP Multicast SNR LINE OUT output level 1000mV industrial standard amphenol connector Operation temperature Operation humidity Overall power consumption 10W Machine size Operating voltage DC24V 132x81x38mm Net weight 0 9Kg 5 40 Model GGM IPAI1 20 80 relative humidity without moisture condensation WWW GIGAMEDIA NET ...

Page 11: ...8 BOTTOM CASE INSTALLATION DIMENSION FIGURE 11 Directly above WWW GIGAMEDIA NET ...

Page 12: ...VersionV0 1 IP NETWORK PA SYSTEM ...