5
GGM AXA1
- Series access control
User Manual
EN
6. Installation
• Remove the back cover from the keypad using the supplied special screw driver
• Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
• Put the supplied rubber bungs to into the two holes
• Fix the back cover fi rmly on the wall with 2 Self tapping screws
• Thread the cable through the cable hole
• Attach the keypad to the back cover.
1 2 3
4 5 6
7 8 9
*
0 #
7. Wiring
Colour
Function
Description
Pink
BELL_A
Doorbell button one end
Pale blue
BELL_B
Doorbell button to the other end
Green
D0
WG output D0
White
D1
WG output D1
Grey
ALARM
Alarm negative(alarm positive connected 12 V+)
Yellow
OPEN
Exit button one end(the other end connected GND)
Brown
D_IN
Magnetic switch one end(the other end connected GND)
Red
12V+
12V + DC Regulated Power Input
Black
GND
12V - DC Regulated Power Input
Blue
NO
Relay normally-on end(Connect positive electric lock «-»)
Purple
COM
Relay Public end, connect GND
Orange
NC
Relay Closed end(connect negative electric lock «-»)