Gigahertz Solutions HFE35C Manual Download Page 1

Made in Germany

 

© Gigahertz Solutions GmbH 

 

HFE35C  

(27 MHz-2,7GHz)

 

 

 

               LogPer-Antenna                UBB27-Antenna  
                                                 (basic ohne/without UBB27)

 

 

 

Deutsch 

Seite 1

 

HF-Analyser

  

Hochfrequenz-Analyser  für  Frequenzen  von 
27 MHz bis 2,7 GHz  

Bedienungsanleitung 

English 

Page 11

 

RF-Analyser 

High Frequency Analyser for Frequencies 
from 27 MHz to 2.7 GHz  

Manual 

 

Rev. 10

 

Summary of Contents for HFE35C

Page 1: ...ogPer Antenna UBB27 Antenna basic ohne without UBB27 Deutsch Seite 1 HF Analyser Hochfrequenz Analyser für Frequenzen von 27 MHz bis 2 7 GHz Bedienungsanleitung English Page 11 RF Analyser High Frequency Analyser for Frequencies from 27 MHz to 2 7 GHz Manual Rev 10 ...

Page 2: ...Made in Germany Gigahertz Solutions GmbH ...

Page 3: ...unbedingt vor der ersten Inbetrieb nahme aufmerksam durch Sie gibt wichtige Hinweise für den Gebrauch die Sicherheit und die Wartung des Gerätes Thank you We thank you for the confidence you have shown in buying a Gi gahertz Solutions product It allows for an easy evaluation of your exposure to high frequency HF radiation according to the rec ommendations of the building biology In addition to thi...

Page 4: ... Materialien Besonders für eine Innenraummessung ist es wichtig zu wissen dass Baumaterialien von hochfrequente Strahlung unterschiedlich stark durchdrungen werden Ein Teil der Strahlung wird auch re flektiert oder absorbiert Beispielsweise sind Holz Gipskarton oder Fenster rahmen oft sehr durchlässig Mehr Informationen hierzu finden Sie auf unserer website Polarisation Hochfrequente Strahlung Wel...

Page 5: ...Schritt Anleitung zur Ermittlung der Gesamtbelastung Wenn Sie ein Gebäude eine Wohnung oder ein Grundstück HF technisch vermessen möchten so empfiehlt es sich immer die Einzelergebnisse zu protokollieren damit Sie sich im nachhinein ein Bild der Gesamtsituation machen zu können Vorbemerkung zu den Antennen Für die Ermittlung der Gesamtbelastung sollten Sie die UBB Antenne verwenden nur beim HFE35C...

Page 6: ...nd unten erfasst werden durch Veränderung der Messposition also des Messpunk tes um nicht zufällig genau an einem Punkt zu messen an dem lokale Auslöschungen auftreten Allgemein anerkannt ist es den höchsten Messwert im Raum zum Vergleich mit Grenz und Richtwerten heranzuziehen Bewertung unterschiedlicher Funkdienste Die Geräte dieser Baureihe zeigen auf dem Display die summari sche Leistungsfluss...

Page 7: ...abwarten bis sich ein Gleichgewicht aus Rücklauf und Erhöhung einstellt Das kann einige Minuten dauern Sie he Abbildung auf der nächsten Seite Peak hold Peak Radar symbolische Darstellung Smart Meters senden sehr unregelmäßig und mit ortsüblichen Mobilfunkbetreibern in Pulsen an den Provider Dazu kommen teilweise noch drahtlose Kurzzeitverbindungen innerhalb des Hauses Deshalb so lange messen bis ...

Page 8: ...n o ä Die danach verbliebene HF Strahlung muss also von außen kommen Für die Festlegung von Abschirmmaßnahmen ist es wichtig diejenigen Bereiche von Wänden mit Türen Fenstern Fensterrahmen Decke und Fußbo den zu identifizieren durch welche die HF Strahlung eindringt Hierzu sollte man niemals mitten im Raum stehend rundherum sondern nahe an der gesamten Wand Decken Bodenfläche nach außen gerichtet ...

Page 9: ...t der UBB Antenne erfassbaren Frequenzbereich gibt es relativ viele ungepulste Sender Diese Markierung wie auch Klangbeispiele verschiedener Sig nalquellen finden Sie als MP3 Files auf unserer homepage Die Audioanalyse lässt sich mit den Frequenzfiltern aus unserem Hau se nochmals deutlich vereinfachen und präzisieren Weiterführende Analysen Von Gigahertz Solutions sind erhältlich Vorsatz Dämpfung...

Page 10: ...rn die Batterie möglichst bald zu ersetzen Fachgerechte Abschirmung ist eine zuver lässige Abhilfemaßnahme Physikalisch nachweisbar wirksam sind fachgerecht ausgeführte Abschirmungen Dabei gibt es eine große Vielfalt von Möglichkei ten Eine allgemein gültige beste Abschirmlösung gibt es jedoch nicht sie muss immer an die individuelle Situation angepasst sein Eine sehr informative Seite zum Thema E...

Page 11: ...eable for HF radiation to a varying degree Some part of the radiation will also be reflect ed or absorbed Wood drywall and wooden window frames for example are usually rather transparent spots in a house More information can be found on our website Polarisation Most High Frequency radiation waves is vertically or horizon tally polarised With the antenna attached the meter measures the vertically p...

Page 12: ...al pollution the UBB Antenna should be used as it it has an omnidirectional reception pattern For the identification of the sources or leaks for the pollution the LogPer Antenne Christmas tree is more suitable for frequen cies above 800 MHz only that is mobile phones WLAN etc The antenna dampens frequencies below 800 MHz in order to avoid the readings being disturbed by lower frequency sources The...

Page 13: ...he often dominating sources of DECT and GSM as well as analogue sources Simply take the readings and compare them to the building biology standard values To be able to evaluate the different radio standards and transmis sion and modulation patterns with one single measurement tech nology the following approach to compensate for these differ ences is recommended UMTS 3G LTE 4G WiMAX DVB WLAN during...

Page 14: ...er al radar beam passes displayed and multiply it by 10 When using the HF38B you can set the switch to Peak hold and allow for several beam passes to establish the equilibrium of charging and droop rate of the holding ca pacitor The reading may take a few minutes to stabilize Smart meters transmit data to the respective providers very ir regularly and in pulses by using the locally available cell ...

Page 15: ...this is completed the remaining radiation will originate from outside For remedial shielding it is important to identify those areas of all walls includ ing doors windows and window frames of ceiling and floor which are penetrated by the radiation To do this one should not stand in the centre of the room measuring in all directions from there but monitor the permeable areas with the antenna LogPer...

Page 16: ... contents of the total signal Within the frequency range cov ered only by the UBB antenna unpulsed signals are quite com mon On our home page you will find a link to some typical samples of audio analyses as MP3 files as well as the marking signal Fur thermore the audio analysis can be significantly simplified by the filters we offer For more in depth analyses Gigahertz Solutions offers Attenuator...

Page 17: ...the lid s re sistance during opening Auto Power Off This feature conserves energy and extends the total operating time 1 In case you have forgotten to turn OFF the HF analyzer or it has been turned ON accidentally during transport it will shut off automatically after 40 minutes of continuous use 2 If LOW BATT appears vertically between the digits in the centre of the display the HF analyzer will t...

Page 18: ...elding too is covered comprehensively on our homepage which also contains further links on this issue Warranty We provide a two year warranty on factory defects of the HF ana lyzer the antenna and accessories Antenna Even though the antenna appears to be rather delicate it is made of a highly durable FR4 base material that can easily withstand a fall from table height HF Analyzer The analyzer itse...

Page 19: ... 0 06 4 76 6 0 47 6 600 476 0 07 5 14 7 0 51 4 700 514 0 08 5 49 8 0 54 9 800 549 0 09 5 82 9 0 58 2 900 582 0 10 6 14 10 0 61 4 1000 614 0 12 6 73 12 0 67 3 1200 673 0 14 7 26 14 0 72 6 1400 726 0 16 7 77 16 0 77 7 1600 777 0 18 8 24 18 0 82 4 1800 824 0 20 8 68 20 0 86 8 2000 868 0 25 9 71 25 0 97 1 2500 971 0 30 10 6 30 0 106 3000 1063 0 35 11 5 35 0 115 3500 1149 0 40 12 3 40 0 123 4000 1228 0...

Page 20: ...mbH 20 Hersteller Manufacturer Gigahertz Solutions GmbH Am Galgenberg 12 90579 Langenzenn Germany Tel 49 9101 9093 0 Fax 49 9101 9093 23 www gigahertz solutions de www gigahertz solutions com Ihr Partner vor Ort Your local partner DRU0191 ...