Gigafast EF800-SI Manual Download Page 3

Verify System Operation 

Check each connection by viewing the port status 
indicators shown in the following table. The switch 
EF800-SI monitors various statuses for every port. 
If there is any abnormal condition, please follow  
the trouble-shooting advice detailed  in the next  
section.

 

 

Troubleshooting by the Diagnostic 
LED Indicators

 

LED State 

Indication 

Power On 

Off 

EF800-SI is powered. 
EF800-SI is not powered. 

LNK/ACT On 

Off 
Flashing

Port has established a valid network connection. 
Port has not established a valid network connection   
Traffic is traversing the port. 

100Mbps On 

Off 

Port runs at 100Mbps. 
Port runs at 10Mbps. 

FDX/COL On 

 
Off 

Port operates in full-duplex mode or collision in 
half-duplex mode. 
Port operates in half-duplex mode without collision. 

 

The operation of EF800-SI can be easily monitored 
through panel LED indicators to assist the network 
man ager in ident if ying  problems .  This  sec t ion 
d e s c r i b e s   s o m e   c o m m o n   p r o b l e m s   y o u   m a y  
encounter and together with possible solutions, 
as shown in following. 

 

Symptom:  Power LED does not light up after alternating current 

being 
Afforded. 

Cause: 

Defective power outlet or power cord. 

Solution: 

Check the power outlet by plugging in another device that
functions properly. Or check the power cord with another
device. 

 

Symptom: 

The LED’s, except the power one, don’t light down after 
Power on. 

Cause: RESET 

functions 

improperly. 

Solution: Power 

on 

again. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EF800-SI

Page 1: ...dwidth in every port The device is built with Plug Play Auto Negotiation on all ports as well as Half And Full Duplex Operation Store and Forward and Cut Through transmission mode for easy installation and smooth transition from legacy 10Mbps to 100Mbps One uplink port shared with port 1 to facilitate your network expansion To ensure maximum safety and good function please read carefully and follo...

Page 2: ...uter s network adapter card and the other end to any available port of the switch EF800 SI Be sure not using port 1 and the Uplink port simultaneously Cascading to a Switch or another Hub When attaching the switch EF800 SI to a router or other devices be sure to verify the port type implemented before connecting any cable For straight through Category 5 5e twisted pair cable with RJ 45 plugs 1 Con...

Page 3: ...00Mbps Port runs at 10Mbps FDX COL On Off Port operates in full duplex mode or collision in half duplex mode Port operates in half duplex mode without collision The operation of EF800 SI can be easily monitored through panel LED indicators to assist the network manager in identifying problems This section describes some common problems you may encounter and together with possible solutions as show...

Page 4: ... Sensing RJ 45 Ports 1 Uplink Port Used Instead of Port 1 Data Transfer Rate Fast Ethernet 100Mbps Half Duplex 200Mbps Full Duplex Ethernet 10Mbps Half Duplex 20Mbps Full Duplex Network Cables Unshielded Twisted Pair Cable Topology Star LED Indicators Power Link Activity 100Mbps Full Duplex Collision Performance Specification Transmission Method Store and Forward Cut Through MAC Address Table 8K E...

Page 5: ...dential area is likely to cause interference in which case the user at this own expense will be required to take whatever measure are required to correct the interference CE Mark Declaration of Conformance This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC N55022 1988 CISPR 22 1985 Class A IEC 1000 4 2 1995 4Kv cd 8Kv AD ...