3.  Switch Placement 

 

3.1 Where 

to 

Place 

This 24-port Switch can be placed on a flat surface (your desk, shelf or table) 

or mounted onto a rack. 

Place the 24-port Switch at a location with these connection considerations in 

mind: 

  The Switch is accessible and cables can be connect easily to it 

  The cables connected to the switch are away from sources of electrical 

interference such as radio, computer monitor, and light fixtures 

  There is sufficient space surrounding the Switch to allow for proper 

ventilation (the Switch may not function according to specifications 

beyond temperature of 0 of 50 degree C) 

 

3.2 How 

to 

Place 

a.  Stick the self-adhesive rubber foot pads (that come with this package) 

on each of the 4 concave spaces located on the bottom of the first 

Switch 

 

21

Summary of Contents for EE2400-S

Page 1: ...EE 2400 S 24 port Flexible Switch User Guide 1 ...

Page 2: ...orm or by any means mechanical magnetic electronic optical photocopying manual or otherwise without the prior written permission Trademarks All products company brand names are trademarks or registered trademarks of their respective companies They are used for identification purpose only Specifications are subject to be changed without prior notice Copyright 2004 GigaFast Inc All Right Reserved 2 ...

Page 3: ...e and radiate electromagnetic energy and if not installed and used in accordance with this guide may cause significant interference with radio communication Operation of this equipment in a residential area is likely to cause interference to household appliances in which case the user will be required to amend at his or her own expense CE Declaration of Conformity This is a Class A product In a do...

Page 4: ...Installation Guide Front View Rear View Side View 4 ...

Page 5: ...ow to Place 4 ink Conditions 4 2 Q A 5 1 1 1 Introductio 1 3 Package Content 1 4 LED Info 1 5 Cable Specification 2 Setting up 2 1 Setting Up Terminal 2 3 VLAN Setup 2 4 Trunking Setup 2 5 Store Setting 2 6 Load Default S 3 Switch Placement 3 1 Where to Place 3 3 How to Mount Troubleshooting 4 1 Resolving No L Glossary 5 ...

Page 6: ...re done by using any standard terminal software To increase the versatility of the EE2400 S a large network environment GigaFast engineers have developed an Auto Uplink Detect feature that detects if the connected client is another switch hub NIC or router If so the EE2400 S will automatically make the client port an uplink port When connecting the EE2400 S to a network just plug it in an the EE24...

Page 7: ...0 m cable Ca n ns ission method Store and Forward F Auto negotiation a Memory Buffer share king bandwidth 800Mbps 4 port t N rouping 4 VLAN groups Secure VLAN VLAN Trunking Smart configuration th console port Windows HyperTerminal sup Telix Procomm support on DOS environment tiv Flow Control IEEE 802 3x compliant flow control for full duplex Filtering Address Tabl 2048 MAC address k t Filtering Fu...

Page 8: ...cates lass A CE Mark 100 me 100 meters for switch to station LED layout System Status LEDs Power LED VLAN Trunk LED Station port L Link Act LED FDX Col LE VLAN Trunk LEDs VLAN Group LE VLAN 1 VLAN 2 VLAN 3 VLAN 4 VLAN disp for VLAN sions 440 205 45 m m L Net Weight 3 8 kg Power Input 100 240 P 40 Watt er ting Temperature 0 40 C ra e Temperature 40 65 C mi ity 10 90 EMI Certif FCC C 8 ...

Page 9: ...esive ru Installation Guide 1 LED STATUS CONDITION Power On Switch is receiving power Link Act On Flashing Green Red Port has established a valid link Data packets being received and sent The connection speed is 100 Mbps The connection speed is 10 Mbps FDX Col On Off Flashing The Connection is Full Duplex The connection is Half Duplex Collision detected on the port 9 ...

Page 10: ...Brown 8 Not Used Brown Cable Type and Use Always limit the cable distance to 100 meters 328ft as defined by IEEE specification Connection Speed Cable Type Hub to Hub or Switch 10 Mbps Straight Through Cat 3 4 5 twisted pair Hub to Hub or Switch 100Mbps Straight Through Cat 5 twisted pair Hub to Server or Workstation 10 Mbps Straight Through Cat 3 4 5 twisted pair Hub to Server or Workstation 100Mb...

Page 11: ...n files has not been created create a new connection name Select COM port of PC 2 Connect from the standard RS232 cable 3 PC is running Win95 98 ME 2000 not limited to Start Program Accessories Communications Terminal Exec Hypertrm program if p terminal program If the connection file has been created cancel the new connection request and open t 6 ters as te 960 C Bit 1 Flow C one Set COM port para...

Page 12: ...7 Plug power cord into the Switch and a blank hyper terminal page will appear as follow 8 Press Enter key 12 ...

Page 13: ...2 2 Port Setup Now we are in the Switch setup MAIN MENU Now press 1 then the screen will be as follow 13 ...

Page 14: ...ection in the setup menu to setup the configuration of the bandwidth and half full duplex mode for each port If the auto negotiation is disabled users can set the connection speed full half duplex of the connection ports The default setting is auto negotiation enable F connection ports 14 ...

Page 15: ...Once a port is done setting up the menu will display the new settings as follow 15 ...

Page 16: ... In order to do so first we will press 2 in the Enter Port Number area Then 2 again in the enter VLAN ID Number area And finally A in Add or Remove area There will only 4 VLAN groups allowed It will be up to the user to decide which port goes into which VLAN group It is also allowed to have identical ports to be multiple VLAN groups If any change is made the screen will refresh and display the new...

Page 17: ...Now we will try to remove a port from a VLAN group Press 1 in the Enter Port Number area then press 1 in the Enter VLAN ID Number and finally R in the Add or Remove area 17 ...

Page 18: ...e forced to a setting of 4 VLAN groups with port 1 2 3 4 5 6 in VLAN1 port 7 8 9 10 11 12 in VLAN2 port 13 14 15 16 17 18 in VLAN3 and port 19 20 21 22 23 24 in VLAN4 Ports 6 7 18 19 will be used as the trunking ports Users will have the choice of enabling or disabling this function However the default VLAN settings and trunking settings cannot be changed Users must use the default setting if they...

Page 19: ...e user is done configuring this Switch user must store the new settings in order for them to take effects To do this press 4 at the MAIN MENU where it says Store Setting The Switch will write the new settings that the users have specified to the EEPROM that is build in the Switch 19 ...

Page 20: ... Switch users must press 5 at the MAIN MENU where it says Load Default Setting Then the Switch will be set to the original factory default setting Reset Device If the device needs a reset users can do so by pressing 6 at the MAIN MENU where it says Reset Device Then the device will automatically reset itself 20 ...

Page 21: ... to it The cables connected to the switch are away from sources of electrical interference such as radio computer monitor and light fixtures There is sufficient space surrounding the Switch to allow for proper ventilation the Switch may not function according to specifications beyond temperature of 0 of 50 degree C 3 2 How to Place a Stick the self adhesive rubber foot pads that come with this pac...

Page 22: ... are as follow The attached device is not powered on The cable may not be the correct type or is faulty The installed building premise cable is faulty The Switch port may be faulty 4 2 Q A 1 Computer A can connect to Computer B but can not connect to Computer C through the 24 port Switch Computer A and Computer C may be in the different VLAN groups Please check the VLAN setup from the Console port...

Page 23: ...erminal programs in DOS Unix OS2 to configure the Switch The user interface is similar with HyperTerminal Please refer to the user guide of that terminal program But the COM port parameters must be Baud Rate 9600 Data Bits None Stop bit 1 Flow Control None PROCOMM and TELIX is DOS terminal program User can use these programs to configure the Switch 5 Glossary What is VLAN Since VLAN solutions and ...

Page 24: ...fits of 4 times bandwidth up to 800Mbps 4 200Mbps in full duplex Especially when multimedia applications and other Bandwidth intensive applications on intranets increase more than ever EtherEngine 2400 S is you right choice to solve bandwidth bottleneck with a trunking bandwidth as impressive as a full 800Mbps What is Auto Uplink Auto Uplink detects if the connected client is another switch hub or...

Reviews: