Gigabyte R162-ZA0 User Manual Download Page 103

- 49 -

BIOS Setup

Parameter

Description

Disable Memory Error Injection

Options available: False/True. Default setting is 

True

.

ECC Configuration

Press [Enter] to configure advanced items.

 

Š

DRAM ECC Symbol Size

 

Configures the DRAM ECC Symbol Size.

 

– Options available: Auto, x4, x8, x16. Default setting is 

Auto

.

 

Š

DRAM ECC Enable

 

– Enable/Disable DRAM ECC. When set to Auto, it will set ECC 

to enable.

 

– Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

 

Š

DRAM UECC Retry

 

– Enable/Disable DRAM UECC Retry.

 

– Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

Summary of Contents for R162-ZA0

Page 1: ...R162 ZA0 AMD EPYC 7002 Server System 1U 4 Bay User Manual Rev 1 0...

Page 2: ...and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short...

Page 3: ...uide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any da...

Page 4: ...the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNI...

Page 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some...

Page 6: ...n if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the man...

Page 7: ...ver 26 3 2 Removing and Installing the Fan Duct 27 3 3 Removing the Heat Sink 28 3 4 Installing the CPU 29 3 5 Installing the Memory 31 3 5 1 Eight Channel Memory Configuration 31 3 5 2 Installing a M...

Page 8: ...onfiguration 77 5 2 17 Tls Auth Configuration 78 5 2 18 Intel R I350 Gigabit Network Connection 79 5 2 19 VLAN Configuration 81 5 2 20 MAC IPv4 Network Configuration 83 5 2 21 MAC IPv6 Network Configu...

Page 9: ...it 143 5 10 9 PMU test points 146 5 10 10 ABL0 test points 146 5 10 11 ABL5 test points 146 5 11 Agesa POST Codes 150 5 11 1 Universal Post Code 150 5 11 2 0xA1XX For CZ only memory Postcodes 150 5 11...

Page 10: ...10 This page intentionally left blank...

Page 11: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Page 12: ...ot of Trust Support Supported NOTE The system will take extra time to boot as it goes through RoT authentication Memory 16 x DIMM slots DDR4 memory supported only 8 Channel memory architecture RDIMM m...

Page 13: ...ee NOTE below NOTE 1 GIGABYTE offers an optional riser card to support full bandwidth PCIe Gen4 x16 and OCP 2 0 Gen3 x8 2 Contact GIGABYTE sales rep or technical support for more details about support...

Page 14: ...TPM2 0 kit CTM010 System Management Aspeed AST2500 management controller GIGABYTE Management Console AMI MegaRAC SP X web interface Dashboard JAVA Based Serial Over LAN HTML5 KVM Sensor Monitor Volta...

Page 15: ...DC Output 800W 12V 66A 12Vsb 2 5A Operating Properties Operating temperature 10 C to 35 C Operating humidity 8 to 80 non condensing Non operating temperature 40 C to 60 C Non operating humidity 20 to...

Page 16: ...01E 8 Channel RDIMM LRDIMM DDR4 16 x DIMMs Up to 3200 1DPC 2933 2DPC MHz USB3 0 x2 Front 2 x USB3 0 Rear 2 x USB3 0 USB HUB GL3523 USB3 0 x2 VGA NCSI COM ASPEED AST2500 RGMII MAC BMC PCIe2 0 x1 LPC 1...

Page 17: ...ce 2 1 Front View No Description 1 USB 3 0 Port x 2 2 Front Panel LEDs and Buttons Orange HDD Latches Support NVMe Refer to section 2 3 Front Panel LEDs and Buttons for a detailed description of the f...

Page 18: ...rd Slot Option OCP 3 0 SFF 3 ID Button with LED 4 Server Management LAN Port 5 GbE LAN Port x 2 6 USB 3 0 Port x 2 7 Mezzanine Card Slot Option OCP 2 0 8 VGA Port Refer to section 2 5 Rear System LAN...

Page 19: ...transmission or receiving is occuring 5 HDD Status LED Green On Indicates locating the HDD Blink Indicates accessing the HDD Amber On Indicates HDD error Green Amber Blink Indicates HDD rebuilding N A...

Page 20: ...times per second Blinks Green 4 times per second Recovering BIOS Active Flash Blinks Blue 4 times per second Blinks Green 4 times per second Authentication AUTH Pass Recovering BIOS Active Flash OFF...

Page 21: ...second ON OFF ON OFF NOTE 1 EC FW is broken or not exited result in Microchip CEC1702 cannot load EC FW for authentication 2 1 Authentication fail include below scenarios Configuration table is missi...

Page 22: ...Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or rec...

Page 23: ...z Green Blinking Power supply firmware updateing mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut...

Page 24: ...HDD is regarded as faulty RAID SKU LED 1 Locate HDD Fault Rebuilding HDD Access HDD Present No Access No RAID configuration via HBA Disk LED LED on Back Panel Green ON 1 OFF BLINK 2 OFF Amber OFF OFF...

Page 25: ...er you are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare me...

Page 26: ...structions to remove the chassis cover 1 Remove the screw securing the chassis cover 2 Loosen the thumbscrew securing the chassis cover 3 Push down the indentations located on the sides of the chassis...

Page 27: ...d Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the two fan ducts 2 To install the fan duct align the fan duct with the guiding groove Push down...

Page 28: ...he fan duct 1 Loosen the captive screws securing the heatsink in place in reverse order 4g3g2g1 2 Lift and remove the heat sink from the system 3 To reinstall the heat sink reverse steps 1 2 while ens...

Page 29: ...cedures described in the following sections unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover in seque...

Page 30: ...System Hardware Installation 30 CPU 4 5 6 2 3 1 7...

Page 31: ...E0 DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_B0 DIMM_P0_B1 DIMM_P0_C0 DIMM_P0_C1 DIMM_P0_D0 DIMM_P0_D1 CPU0 Read the following guidelines before you begin to install the memory Make sure that the motherboard supp...

Page 32: ...erboard Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock...

Page 33: ...Table 1 2 DIMMs Populated DIMM 2S2R 2S4R 1 2 2933 2666 1 2V Frequency MT s NOTE l 1R 1 package rank of SDP DRAMs l 2R 2 package rank of SDP DRAMs l 2DR 2 package rank of DDP DRAMs l 4DR 4 package ran...

Page 34: ...PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Loosen the thumbscre...

Page 35: ...ns to install an OCP 3 0 mezzanine card 1 Remove the two screws securing the mezzanine card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 3 0 mezzanine card into the card slot en...

Page 36: ...of system 3 Remove the screw securing the mezzanine card slot cover 4 Remove the slot cover from the system 5 Insert the OCP 2 0 mezzanine card into the compartment ensuring that the card is firmly co...

Page 37: ...is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the dire...

Page 38: ...eplacement fan assembly Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Ensure that th...

Page 39: ...supply 1 Press the retaining clip on the right side of the power supply along the direction of the arrow 2 Pull up the power supply handle at the same time and pull out the power supply 3 Insert the r...

Page 40: ...System Hardware Installation 40 3 11 Cable Routing Front Switch Cable Front LED Cable Front Panel USB 3 0 Cable...

Page 41: ...41 System Hardware Installation HDD Backplane Board Power Cable HDD Backplane Board Signal Cable...

Page 42: ...System Hardware Installation 42 Power Distribution Board Signal Cable System Power Cable...

Page 43: ...43 System Hardware Installation SlimLine to SATA Cable...

Page 44: ...System Hardware Installation 44 This page intentionally left blank...

Page 45: ...E0 DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_B0 DIMM_P0_B1 DIMM_P0_C0 DIMM_P0_C1 DIMM_P0_D0 DIMM_P0_D1 CPU0 1 2 3 4 6 5 7 9 8 10 12 11 14 15 16 13 17 18 19 20 21 Item Description 1 Front Panel USB 3 0 Connector 2...

Page 46: ...onnector OCP 2 0 Gen3 x8 13 2 x 5 Pin P12V Power Connector 14 System Battery 15 Riser Connector 2 PCIe Gen4 x32 Slot 16 Riser Connector 3 PCIe Gen4 x16 Slot 17 2 x 6 Pin Power Connector 18 Riser Conne...

Page 47: ...rmal Default BIOS Defined BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL PMBUS_SEL BIOS_PWD BIOS_RCVR Normal Default J2 1 2 3 4 Clear CMOS CLR_CMOS Enable Default 1 2 3 NCSI Switch Onboard...

Page 48: ...Motherboard Components 48 This page intentionally left blank...

Page 49: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Page 50: ...the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to...

Page 51: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Page 52: ...of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays A...

Page 53: ...Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode S...

Page 54: ...tup 54 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section Parameter Description ErP Mode Enable Disable ErP Lot 9 suuport Options available Enable Disable Default setting is D...

Page 55: ...le BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Suppo...

Page 56: ...BIOS Setup 56 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable...

Page 57: ...nBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mo...

Page 58: ...4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 2 Configuration Press Enter for configuration...

Page 59: ...Serial Port COM When set to Enabled allows you to configure the Serial port 1 2 settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default s...

Page 60: ...10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3...

Page 61: ...ion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Di...

Page 62: ...LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type...

Page 63: ...2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the...

Page 64: ...S Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default se...

Page 65: ...a loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the fl...

Page 66: ...e the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default settin...

Page 67: ...49 BIOS Setup 5 2 8 AMI Graphic Output Protocol Policy Parameter Description ASPEED Graphics PCI Adapter ASPEED Graphics Driver Output Select Press Enter to select output interface...

Page 68: ...BIOS Setup 68 5 2 9 PCI Subsystem Settings...

Page 69: ...O ROM When enabled this setting will initialize the device expansion ROM for the related U 2 device Options available Enabled Disabled Default setting is Enabled OCP Note2 Max Link Speed Configure mez...

Page 70: ...f Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support...

Page 71: ...or a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 AMI HDisk0 1 00 Gen...

Page 72: ...BIOS Setup 72 5 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system...

Page 73: ...49 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Page 74: ...BIOS Setup 74 5 2 13 UEFI Configuration Parameter Description UEFI Configuration Select output device type...

Page 75: ...etting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature O...

Page 76: ...BIOS Setup 76 5 2 15 AMD Mem Configuration Status Parameter Description CPU0 1 Press Enter to view the memory configuration status related to CPU 0...

Page 77: ...nitiator Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure adva...

Page 78: ...guration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Page 79: ...49 BIOS Setup 5 2 18 Intel R I350 Gigabit Network Connection...

Page 80: ...Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network...

Page 81: ...49 BIOS Setup 5 2 19 VLAN Configuration...

Page 82: ...he keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired...

Page 83: ...ote Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gatewa...

Page 84: ...BIOS Setup 84 5 2 21 MAC IPv6 Network Configuration...

Page 85: ...string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A...

Page 86: ...86 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related subm...

Page 87: ...H cloak individual banks and mask deferred error interrupts from each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Bo...

Page 88: ...e Auto Enabled Disabled Default setting is Auto MCA error thresh enable Enable MCA error thresholding Options available Auto False True Default setting is Auto SMU and PSP Debug Mode When this option...

Page 89: ...Pstates When accepted you can disable or customize core pstates CCD Core Thread Enablement Allows you to accept or decline enabling CCDs processor cores and threads When accepted you can control the...

Page 90: ...tcher settings L1 Stream HW Prefetcher Enable Disable L1 Stream HW Prefetcher Options available Auto Enabled Disabled Default setting is Auto L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefet...

Page 91: ...setting is Auto Core Watchdog Timer Interval Note Enable Disable CPU Watchdog Timer Interval Options available Auto Enabled Disabled Default setting is Auto Core Watchdog Timer Enable Serverity Note...

Page 92: ...isable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default...

Page 93: ...e Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto...

Page 94: ...remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options...

Page 95: ...ptions available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT...

Page 96: ...bounds Control Options available Auto Manual Default setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default settin...

Page 97: ...Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced...

Page 98: ...o enable 2 DIMMs per Channel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter t...

Page 99: ...RAM Power OptionsMa Power Down Enable Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto...

Page 100: ...guration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD b...

Page 101: ...1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Defa...

Page 102: ...ion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurabl...

Page 103: ...ems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable...

Page 104: ...ameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enab...

Page 105: ...No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address...

Page 106: ...BIOS Setup 106 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No...

Page 107: ...asures Voltage vs Timing Options available Auto Both Interface Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disab...

Page 108: ...l function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggr...

Page 109: ...oltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available...

Page 110: ...Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SMU Common Options Press Enter for configuratio...

Page 111: ...ode Controls the Presence Detect Select mode Options available Auto OR AND Default setting is Auto Preferred IO Device Configures Preferred IO Device Options available Auto Manual Default setting is A...

Page 112: ...or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto CLD0_VDDP Control Options available Auto Manual Default setting is Auto Effi...

Page 113: ...ture Options available Auto Enabled Disabled Default setting is Auto HSMP Support Select HSMP support enable or disable Options available Auto Enabled Disabled Default setting is Auto Diagnostic Mode...

Page 114: ...on the associated IOHC egress port A bit of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disab...

Page 115: ...efault setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable D...

Page 116: ...tup 116 5 3 5 FCH Common Options Parameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advance...

Page 117: ...Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is La...

Page 118: ...Link RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to syst...

Page 119: ...49 BIOS Setup 5 3 6 NTB Common Options Parameter Description NTB Common Options NTB Enable Options available Auto Enabled Default setting is Auto...

Page 120: ...able Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options avai...

Page 121: ...e function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description RAS Press Enter for configuration of advanced items SPI Locking Enable Disable S...

Page 122: ...eriod GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for unco...

Page 123: ...the PCIe AER Uncorrected Error Serverity register of PCIe device CCIX GHES Deferred ERR Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting i...

Page 124: ...creen Parameter Description PCIe Link Training Type Configures the PCIe Link training in 1 or 2 steps Options available 1 Step 2Step Default setting is 1 Step PCIe Compliance Mode Options available On...

Page 125: ...Setup 5 5 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related...

Page 126: ...et Power Down Default setting is Do Nothing Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available...

Page 127: ...ent Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configur...

Page 128: ...SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Not...

Page 129: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Page 130: ...lable Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP addres...

Page 131: ...ork during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIO...

Page 132: ...l settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Page 133: ...ecure Boot requires all the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows lo...

Page 134: ...Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append A...

Page 135: ...er of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function...

Page 136: ...re the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Ent...

Page 137: ...ities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message...

Page 138: ...rities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message i...

Page 139: ...e so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of r...

Page 140: ...ce 0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public inte...

Page 141: ...BL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Inte...

Page 142: ...init 0xE057 Exit point CPU APOB EDC info init 0xE058 5 10 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 5 10 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3...

Page 143: ...de 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug co...

Page 144: ...Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGM...

Page 145: ...AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allo...

Page 146: ...Initialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchro...

Page 147: ...DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for He...

Page 148: ...Error 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted...

Page 149: ...30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Er...

Page 150: ...107 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTrai...

Page 151: ...Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Chan...

Page 152: ...A187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For...

Page 153: ...ode calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate a...

Page 154: ...V2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save ar...

Page 155: ...and MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mai...

Page 156: ...0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910...

Page 157: ...bioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0x...

Page 158: ...ate exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 5 11 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX...

Page 159: ...h finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 F...

Page 160: ...xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH Ini...

Page 161: ...was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 12 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Ar...

Page 162: ...49 BIOS Setup This page intentionally left blank...

Reviews: