background image

MZ72-HB0

AMD EPYC™ 7003 Dual Sockets Server Motherboard

User Manual

Rev. 3.0

Summary of Contents for MZ72-HB0

Page 1: ...MZ72 HB0 AMD EPYC 7003 Dual Sockets Server Motherboard User Manual Rev 3 0...

Page 2: ...BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short gui...

Page 3: ...rnal Connectors 18 1 8 Jumper Settings 27 Chapter 2 BIOS Setup 28 2 1 The Main Menu 30 2 2 Advanced Menu 33 2 2 1 Trusted Computing 35 2 2 2 PSP Firmware Versions 36 2 2 3 Legacy Video Select 37 2 2 4...

Page 4: ...us Control 107 2 3 8 Workload Tuning 108 2 4 AMD PBS Menu 109 2 4 1 RAS 110 2 5 Chipset Setup Menu 112 2 5 1 North Bridge 113 2 5 2 Fabric Resource 114 2 6 Server Management Menu 115 2 6 1 System Even...

Page 5: ..._P0_C0 DIMM_P0_D0 DIMM_P0_H0 DIMM_P0_G0 DIMM_P0_F0 DIMM_P0_E0 DIMM_P1_L0 DIMM_P1_K0 DIMM_P1_J0 DIMM_P1_I0 DIMM_P1_M0 DIMM_P1_N0 DIMM_P1_O0 DIMM_P1_P0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...

Page 6: ...I 6Gb s Connector 2 19 SATA1 SATAIII 6Gb s Connector 1 20 SATA0 SATAIII 6Gb s Connector 0 21 SYS_FAN2 System Fan Connector 2 22 BAT Battery Socket 23 SYS_FAN1 System Fan Connector 1 24 F_USB3 Front Pa...

Page 7: ...7 Block Diagram...

Page 8: ...8 This page left intentionally blank...

Page 9: ...y and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before un...

Page 10: ...ports 1 x Broadcom BCM57416 1 x 10 100 1000 management LAN Expansion Slots Slot_6 1 x PCIe x16 Gen4 x16 bus slot from CPU_0 Slot_4 1 x PCIe x16 Gen4 x16 bus slot from CPU_0 Slot_3 1 x PCIe x16 Gen4 x...

Page 11: ...1 x TPM header 1 x Front panel header 1 x PMBus connector 1 x IPMB connector 1 x Clear CMOS jumper 1 x BIOS recovery jumper Rear I O Connectors 2 x USB 3 0 ports 1 x VGA port 1 x Serial port 2 x RJ45...

Page 12: ...es before you begin to install the CPU Make sure that the motherboard supports the CPU Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent...

Page 13: ...dware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction 1 4 1 8 Channel Memory Configurat...

Page 14: ...the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 1 4 3 Processor and Memory Module Matrix Table P...

Page 15: ...4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 2S2R 4 Ranks 2S2R 4 Ranks 2933 2S4R 8 Ranks 2S4R 8 Ranks 2933 3DS 2S2R 4 Ranks 2933 2S2R 4 Ranks 2S2R 4 Ranks 2666 2S4R 8 Ranks 2933 2S4R 8 R...

Page 16: ...ving the M 2 SSD Module Follow the steps below to install an optional M 2 SSD module on your motherboard Step1 Insert the M 2 SSD module into the slot Step2 Secure it with the screw tightening as nece...

Page 17: ...t up to 10 Gbps data rate See the section below for a description of the states of the LAN port LEDs z ID button with LED When the system identification is active the ID LED on the front back panel gl...

Page 18: ...uter make sure the device cable has been securely attached to the connector on the motherboard 1 ATX 14 SYS_FAN4 2 P12V_1 for CPU0 15 SYS_FAN4 3 P12V_2 for CPU1 16 PMBUS 4 SATA0 17 F_USB3 5 SATA1 18 F...

Page 19: ...2V power connector mainly supplies power to the CPU If the 12V power connector is not connected the computer will not start To meet expansion requirements it is recommended that a power supply that ca...

Page 20: ...h SATA 3Gb s standard Each SATA connector supports a single SATA device Pin No Definition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 7 8 SATA_SGP SATA SGPIO Connector Serial General Purpose Input Out...

Page 21: ...fan speed control design For optimum heat dissipation it is recommended that a system fan be installed inside the chassis 1 1 Pin No Definition 1 GND 2 12V 3 Sense 4 Speed Control Be sure to connect f...

Page 22: ...P1_SSRX 13 GND 4 GND 14 IntA_P2_SSTX 5 IntA_P1_SSTX 15 IntA_P2_SSTX 6 IntA_P1_SSTX 16 GND 7 GND 17 IntA_P2_SSRX 8 IntA_P1_D 18 IntA_P2_SSRX 9 IntA_P1_D 19 Power 10 NC 20 No Pin 18 COM2 Serial Port Cab...

Page 23: ...h power LED hard drive activity LED speaker etc When connecting your chassis front panel module to this header make sure the wire assignments and the pin assignments are matched correctly Pin No Defin...

Page 24: ...T 21 PH_HP_SCL0 22 GND 23 PH_HP_SDA0 24 GND 25 PH_HP_SCL1 26 GND 27 PH_HP_SDA1 28 GND 15 P3V3_AUX 30 P3V3_AUX 29 30 2 1 21 SPI_TPM Trusted Platform Module Connector Trusted Platform Module TPM is an i...

Page 25: ...s Protocol defines a byte level transport for transferring Intelligent Platform Management Interface Specification IPMI messages between intelligent I2C devices 4 1 Pin No Definition 1 Clock 2 GND 3 D...

Page 26: ...ry with an equivalent one Danger of explosion if the battery is replaced with an incorrect model Contact the place of purchase or local dealer if you are not able to replace the battery by yourself or...

Page 27: ...tting Clear CMOS 1 2 Normal operation Default 2 3 Clear CMOS data J1 ON OFF 1 HSMB_SEL BIOS Defined 2 N A BIOS Defined 3 BIOS PWD Clear Supervisor Password Normal Default 4 BIOS Recovery BIOS Recovery...

Page 28: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Page 29: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to...

Page 30: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Page 31: ...ormation Processor Information CPU0 Brand String CPU1 Brand String CPU Speed Processor Core Microcode Patch Displays the technical specifications for the installed processor s Total Memory Note2 Displ...

Page 32: ...PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note Displays LAN MAC address information LAN2 MAC Address Note Displays LAN MAC address information System Da...

Page 33: ...Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode S...

Page 34: ...BIOS Setup 34 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section...

Page 35: ...le BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Suppo...

Page 36: ...BIOS Setup 36 2 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable...

Page 37: ...37 BIOS Setup 2 2 3 Legacy Video Select Parameter Description OnBrd Ext VGA Select Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard...

Page 38: ...4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 2 Configuration Press Enter for configuration...

Page 39: ...39 BIOS Setup 2 2 4 1 Serial Port 1 2 Configuration...

Page 40: ...gs for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9...

Page 41: ...gs Parameter Description Wake System from S5 Enable Disable system wake on alarm event Options available Disabled Fixed Time Dynamic Time When Fixed Time is selected system will wake on the hr min sec...

Page 42: ...erial Over LAN COM2 Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled...

Page 43: ...1 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once t...

Page 44: ...S Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default se...

Page 45: ...a loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the fl...

Page 46: ...onfiguration Parameter Description SVM Mode Enable Disable the CPU Virtualization Options available Enabled Disabled Default setting is Enabled CPU 0 1 Information Press Enter to view the memory infor...

Page 47: ...47 BIOS Setup 2 2 8 PCI Subsystem Settings...

Page 48: ...ard LAN Controller Note3 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note3 Enable Disable the onboard LAN devices and initi...

Page 49: ...t Enable Disable the Legacy USB support function AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Options av...

Page 50: ...t value during a USB mass storage device reset Options available 10 sec 20 sec 30 sec 40 sec Default setting is 20 sec Device power up delay Maximum time the device will take before it properly report...

Page 51: ...he Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enab...

Page 52: ...BIOS Setup 52 2 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system...

Page 53: ...53 BIOS Setup 2 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Page 54: ...13 UEFI POST LOGO Configuration Parameter Description Output Device Type Selects output device type Options available First loaded Device Onboard Device External Device Specific Device Default setting...

Page 55: ...55 BIOS Setup 2 2 14 AMD Mem Configuration Status Parameter Description CPU0 1 Press Enter to view the memory configuration status related to CPU 0 1...

Page 56: ...guration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Page 57: ...sing keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Commit Changes and Exit Host iSCSI Configuration Press Enter to configure advanced items...

Page 58: ...umber of VFs Per PF Configures the number of Virtual Functions Per Physical Function in multiples of 8 1 128 This field is only applicable when SR IOV is enabled Default setting is 8 SR IOV Enable Dis...

Page 59: ...idge Enable Disable LLDP nearest bridge state Options available Enabled Disabled Default setting is Enabled LLDP nearest non TPMR bridge Enable Disable LLDP nearest non TPMR bridge state Options avail...

Page 60: ...able only when VLAN Mode is Enabled Boot Retry Count Selects the number of boot retries Options available No Retry 1 Retry 2 Retries 3 Retries 4 Retries 5 Retries 6 Retries Indefinite Retries Default...

Page 61: ...setting is Enabled This item is configurable when TCP IP Parameters via DHCP is set to Disabled iSCSI Parameters via DHCP Acquires iSCSI Parameters via DHCP Options available Enabled Disabled Default...

Page 62: ...setting is IPv4 iSCSI Initiator Parameters Press Enter to configure advanced items IP Address Configures the initiator IP address Subnet Mask Configures the IP subnet mask Default Gateway Configures...

Page 63: ...e Challenge Handshake Authentication Protocol CHAP Secret 12 to 16 characters in length Secondary Device Press Enter to configure advanced items Secondary Device Inputs the secondary device MAC addres...

Page 64: ...BIOS Setup 64 2 2 18 VLAN Configuration...

Page 65: ...the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desire...

Page 66: ...ote Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gatewa...

Page 67: ...67 BIOS Setup 2 2 20 MAC IPv6 Network Configuration...

Page 68: ...tring is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A...

Page 69: ...tup 2 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related sub...

Page 70: ...BIOS Setup 70 2 3 1 CPU Common Options...

Page 71: ...ns available Auto 253 ASIDs 509 ASIDs Default setting is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs Options available Auto Manual Default setting is Auto Streaming Store...

Page 72: ...be set to zero for analysis purpose as long as OS supports it Options available Disabled Enabled Default setting is Enabled REP MOV STOS Streaming Allows REP MOVS STOS to use non caching streaming st...

Page 73: ...ted you can control the number of CCDs to be used and the number of cores to be used CCD Control Options available Auto 2 CCDs 3 CCDs 4 CCDs 6 CCDs Default setting is Auto Core Control Options availab...

Page 74: ...le Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Enable Disa...

Page 75: ...75 BIOS Setup 2 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto...

Page 76: ...isable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Freeze DF module queues on error Options available Auto Enabled Disabled Default...

Page 77: ...fault setting is Auto Poison scrubber control Enable Disable the Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disabl...

Page 78: ...ons available Auto 256Bytes 512Bytes 1KB 2KB Default setting is Auto 1TB remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configurat...

Page 79: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLI...

Page 80: ...on a multi socket system Options available Auto 2 xGMI Links 3 xGMI Links 4 xGMI Links Default setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 66...

Page 81: ...Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced...

Page 82: ...Default setting is Auto Note To enable 2 DIMMs per Channel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controll...

Page 83: ...DRAM Power Options Power Down Enable Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto...

Page 84: ...uration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bu...

Page 85: ...1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Defa...

Page 86: ...ion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurabl...

Page 87: ...ems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable...

Page 88: ...ription Security TSME Enable Disable transparent secure memory encryption Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available...

Page 89: ...Training DFE Read Training Perform 2D Read Training with DFE on Options available Auto Enable Disable Default setting is Auto FFE Write Training Perform 2D Write Training with FFE on Options available...

Page 90: ...No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address...

Page 91: ...DIMM Parameter Description NVDIMM Displays the information of the devices controllers if installed Disable NVDIMM N Feature Enable Disable NVDIMM N feature for memory margin tool Options available No...

Page 92: ...tting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report...

Page 93: ...led Vendor Tests Disabled All Tests All Vendors Default setting is Vendor Tests Enabled Mem BIST Post Package Repair Type Note1 Selects the repair type for dram errors found in the BIOS memory BIST Op...

Page 94: ...function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggre...

Page 95: ...Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Per Chip Select Read Voltage Sweep Step Size Configures the step...

Page 96: ...I Enumeration ARI Forwarding Enable for each downstream port Options available Auto Enable Disable Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devic...

Page 97: ...to Preferred IO Preferred IO select type Manual Bus Number manually Auto Default Options available Auto Manual Default setting is Auto Data Link Feature Cap Enable Disable the data link feature capabi...

Page 98: ...DP Control Selects use the fused TDP or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information Efficienc...

Page 99: ...lable Auto Enabled Disabled Default setting is Auto DLWM Support Enable Disable the DLWM support Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enab...

Page 100: ...of 0 indicates LOW severity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood...

Page 101: ...Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable...

Page 102: ...rameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press...

Page 103: ...Setup 2 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is L...

Page 104: ...Link RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to syst...

Page 105: ...105 BIOS Setup 2 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Timer Enable Enable Disbale Boot Timer Options available Auto Enabled Disabled Default setting is Auto...

Page 106: ...TB Enable Options available Auto Enable Default setting is Auto Socket 0 P1 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P2 NTB Enable Options available Auto Enable Defaul...

Page 107: ...Console Out Control Note Enable Disable the Basic ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number...

Page 108: ...er Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Au...

Page 109: ...king for protect ROM part Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn enabled Options available...

Page 110: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for unc...

Page 111: ...Notify Type Selects the Notification type for CCIX deferred error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX cor...

Page 112: ...r to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available E...

Page 113: ...tup 2 5 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU 0 1 Information Press Enter to view information relate...

Page 114: ...BIOS Setup 114 2 5 2 Fabric Resource Parameter Description Fabric Resource CPU 0 1 NBIO_ PCIe Bus Number Change CPU 0 1 NBIO_ PCIe Bus Number...

Page 115: ...Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note2 Configures OS Watchdog Timer Options available 5 minutes 10 m...

Page 116: ...ent Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configur...

Page 117: ...se SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do N...

Page 118: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Page 119: ...IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays...

Page 120: ...network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by...

Page 121: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Page 122: ...ll the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login scre...

Page 123: ...e Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Update Append...

Page 124: ...er of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function...

Page 125: ...re the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Ent...

Page 126: ...e so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of r...

Page 127: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 2 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the A...

Reviews: