Gigabyte MU92-TU1 User Manual Download Page 84

BIOS Setup

- 84 -

2-6  Boot Menu

The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error 

message if the legacy drive(s) specified is not bootable.  

Parameter

Description

Boot Configuration

Setup Prompt Timeout

Number of seconds to wait for setup activation key. 65535 (0xFFFF) 

means indefinite waiting.

Press the numeric keys to input the desired values.

Bootup NumLock State

Enable/Disable the Bootup NumLock function.
Options available: On, Off. Default setting is 

On

.

Quiet Boot

Enable/Disable showing the logo during POST.
Options available: Enabled, Disabled. Default setting is 

Enabled

.

Setup Flash

Press [Enter] to run setup flash.

Dump full Setup Data

Press [Enter] to dump full setup data to file.

Dump non-default Setup Data

Press [Enter] to dump non-default setup data to file.

Restore Setup Data

Press [Enter] to restore setup data from file.

Boot mode select

Selects the boot mode.
Options available: LEGACY, UEFI. Default setting is 

UEFI

.

Summary of Contents for MU92-TU1

Page 1: ...MU92 TU1 Intel Socket LGA4189 processor motherboard User Manual Rev 1 0...

Page 2: ...BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short gui...

Page 3: ...alling the M 2 SSD Module 15 1 6 Back Panel Connectors 16 1 7 Internal Connectors 17 1 8 Jumper Settings 26 Chapter 2 BIOS Setup 28 2 1 The Main Menu 30 2 2 Advanced Menu 33 2 2 1 Trusted Computing 34...

Page 4: ...68 2 3 10 Runtime Error Logging Settings 69 2 3 11 Power Policy 71 2 4 Server Management Menu 73 2 4 1 System Event Log 75 2 4 2 View FRU Information 76 2 4 3 BMC VLAN Configuration 77 2 4 4 BMC Netw...

Page 5: ...MM_P0_B0 DIMM_P0_B1 DIMM_P0_D0 DIMM_P0_D1 DIMM_P0_C0 DIMM_P0_C1 DIMM_P0_H1 DIMM_P0_H0 DIMM_P0_G1 DIMM_P0_G0 DIMM_P0_E1 DIMM_P0_E0 DIMM_P0_F1 DIMM_P0_F0 1 2 3 4 5 6 7 8 9 10 11 12 13 17 18 19 20 21 22...

Page 6: ...III 6Gb s Connector 5 18 SSATA4 SATA III 6Gb s Connector 4 19 SSATA_SGP1 SATA SGPIO Connector 20 P12V_AUX1 2x4 Pin 12V Power Connector for CPU 21 FP_1 Front Panel Header 22 F_USB3 Front Panel USB 3 0...

Page 7: ...7 Block Diagram...

Page 8: ...please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off...

Page 9: ...00 management LAN Onboard Graphics Integrated in Aspeed AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SDRAM Storage Interface 2 x 7 pin SATA 6Gb s ports 2 x SlimSA...

Page 10: ...ar CMOS jumper 1 x BIOS recovery jumper 1 x Case open header 1 x Buzzer Rear I O Connectors 2 x USB 3 0 Ports 1 x VGA Port 1 x Serial Port 2 x RJ45 Ports 1 x MLAN Port 1 x ID button with LED TPM 1 x T...

Page 11: ...an P4 Socket 4 1 2 3 4 6 5 Follow these instructions to install the CPU 1 Align and install the processor on the carrier NOTE Apply thermal compound evenly on the top of the CPU Remove the protective...

Page 12: ...are damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction 1 4 1 8 Channel Memory Configuratio...

Page 13: ...c clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 4 3 Memory Population Table Note DIMM must be populated in seq...

Page 14: ...D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D PMem 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D DDR4 PMem 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R D D 4 R...

Page 15: ...ing the M 2 SSD Module Follow the steps below to install a M 2 SSD module on your motherboard Step1 Insert the M 2 SSD module into the slot Step2 Secure it with the screw tightening as necessary to fa...

Page 16: ...ports the USB 3 0 specification Use this port for USB devices such as a USB keyboard mouse USB printer USB flash drive etc ID button with LED When the system identification is active the ID LED on the...

Page 17: ...d before turning on the computer make sure the device cable has been securely attached to the connector on the motherboard 1 ATX1 11 PMBUS 2 P12V_AUX1 for CPU 12 F_USB3 3 P12V_AUX2 for Memory 13 FP_1...

Page 18: ...2V power connector mainly supplies power to the CPU If the 12V power connector is not connected the computer will not start To meet expansion requirements it is recommended that a power supply that ca...

Page 19: ...TA 3Gb s standard Each SATA connector supports a single SATA device Pin No Definition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 7 6 SSATA_SGP1 SATA SGPIO Connector Serial General Purpose Input Outpu...

Page 20: ...the ground wire The motherboard supports CPU fan speed control which requires the use of a CPU fan with fan speed control design For optimum heat dissipation it is recommended that a system fan be ins...

Page 21: ...gement Bus PMBus is a variant of the System Management Bus SMBus which is targeted at digital management of power supplies 5 1 11 10 20 1 Pin No Definition Pin No Definition 1 Power 11 IntA_P2_D 2 Int...

Page 22: ...23 2 Pin No Definition Pin No Definition 1 Power LED 2 5V Standby 3 No Pin 4 ID LED 5 Power LED 6 ID LED 7 HDD LED 8 System Status LED 9 HDD LED 10 System Status LED 11 Power Button 12 LAN1 Active LE...

Page 23: ...nt Interface Specification IPMI messages between intelligent I2C devices 4 1 15 SPI_TPM Trusted Platform Module Connector Trusted Platform Module TPM is an international standard for a secure cryptopr...

Page 24: ...k BMC firmware is ready Off AC loss 17 CN_NCSI NCSI Connector Pin No Definition Pin No Definition 1 NCSI_CLK 2 GND 3 NCSI_RX_D0 4 GND 5 NCSI_RX_D1 6 GND 7 NCSI_CRS_DV 8 GND 9 NCSI_RX_ER 10 GND 11 P3V3...

Page 25: ...date and time information in the CMOS when the computer is turned off Replace the battery when the battery voltage drops to a low level or the CMOS values may not be accurate or may be lost Always tu...

Page 26: ...N_NCSI SW1 OFF SW2 OFF ON OFF 1 2 ON J1 ON OFF 1 HSMS_SEL BIOS defined 2 PMBUS_SEL BIOS defined 3 S3_MASK Stop initial power on when BMC is not ready Normal Default 4 DB_PLD CPLD debug mode Normal Def...

Page 27: ...27 Hardware Installation This page left intentionally blank...

Page 28: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Page 29: ...Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS...

Page 30: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Page 31: ...nd String Max CPU Speed CPU Signature Processor Core Microcode Patch Displays the technical information for the installed processor s Platform Information Processor PCH RC Revision Displays the platfo...

Page 32: ...ays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note2 This section will d...

Page 33: ...u options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default When Boot...

Page 34: ...Description Configuration Security Device Support Enable Disable BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options av...

Page 35: ...tings Press Enter to configure advanced items Please note that this item is configurable when COM1 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console re...

Page 36: ...setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers...

Page 37: ...Management Windows Emergency Management Services EMS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port mana...

Page 38: ...ata loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the...

Page 39: ...o Enabled allows you to configure the serial port settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Current Disp...

Page 40: ...and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB or greater add...

Page 41: ...nd off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled...

Page 42: ...ns available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Di...

Page 43: ...Post Report Configuration Parameter Description Post Report Configuration Error Message Report Post Error Message Enable Disable the POST Error Message support Options available Enabled Disabled Defau...

Page 44: ...s connected to the system NVMe OPROM Select Options available BIOS Build In NVMe Device Default setting is BIOS Build In NVMe LED Control Enable Diable user control NVMe LED This item is only availabl...

Page 45: ...VGA Enable Disable 64bit capable devices to be decoded in Skip Above 4G Address VGA Space Options available Enabled Disabled Default setting is Disabled P2P Bridge IO Size Specifies P2P Bridge IO alig...

Page 46: ...guration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Page 47: ...items Attempt Priority Options available Host Attempt Redfish Attempt Default setting is Host Attempt Commit Changes and Exit Host iSCSI Configuration Press Enter to configure advanced items iSCSI Ini...

Page 48: ...BIOS Setup 48 2 2 12 Intel R X710 Ethernet Network Connection...

Page 49: ...al network port by blinking the associated LED Press the numeric keys to adjust desired values up to 15 seconds UEFI Driver Displays the technical specifications for the Network Interface Controller A...

Page 50: ...VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decreas...

Page 51: ...51 BIOS Setup 2 2 14 Driver Health Parameter Description Driver Health Displays driver health status of the devices controllers if installed...

Page 52: ...Setup 52 2 3 Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub PCH Select a submenu item then press Enter to access the related submenu s...

Page 53: ...53 BIOS Setup 2 3 1 Processor Configuration...

Page 54: ...Default setting is Disable L2 RF0 Prefetch Disable Options available Enable Disable Default setting is Disable Adjacent Cache Prefetch When enabled cache lines are fetched in pairs When disabled only...

Page 55: ...er Description Debug Consent Options available Enable Disable Default setting is Disable Total Memory Encryption TME Enable Disable total memory encryption TME Options available Enabled Disabled Defau...

Page 56: ...is the default allocation Options available 1G 4G 16G 64G 256G 1024G Default setting is 256G Isoc Mode Enable Disable the Isochronous support in order to meet the QoS requirements Quality of Service O...

Page 57: ...available 9 6GT s 10 4GT s 11 2GT s Auto Default setting is Auto SNC Sub NUMA Enable Disable Sub NUMA Cluster function Options available Disable Enable SNC2 2 clusters Default setting is Disable Stal...

Page 58: ...is Auto Enable ADR Enables the detecting and enabling of ADR Asynchronous DRAM Refresh function Options available Enable Disable Default setting is Enable Legacy ADR Mode Enable Disable the Legacy AD...

Page 59: ...pe Displays the RAS type New SDDC Mode Enable Disable 48B SDDC ECC from ICX C0 Onwards Options available Disabled Enabled Default setting is Enabled Mirror Mode Mirror Mode will set entire 1LM memory...

Page 60: ...igh bit 1 63 Press the keys to increase or decrease the desired values ADDDC Sparing Note Enable Disable ADDDC Sparing Options available Disabled Enabled Default setting is Disabled Enable ADDDC Error...

Page 61: ...only to Chipset PCIe Root Ports Bridges Disable Programs ACS to all PCIe bridges Default setting is Enable DMA Control Opt In Flag Enable Disable DMA_CTRL_PLATFORM_OPT_IN_FLAG in DMAR table in ACPI N...

Page 62: ...ration Enable Disable Intel VMD technology Options available Enable Disable Default setting is Disable Intel VMD for Non Hotplug NVMe Note Enable Disable Intel VMD for Non Hotplug NVMe Options availab...

Page 63: ...able Activate SST BF Enable Disable SST BF Options available Enable Disable Default setting is Disable Configure SST BF Note Enable Disable BIOS to configure SST BF High Priority Cores Options availab...

Page 64: ...PU C6 ACPI C3 report to OS Options available Disable Enable Auto Default setting is Disable Enhanced Halt State C1E Core C1E auto promotion control Takes effect after reboot Options available Enable D...

Page 65: ...abled and cannot be access the RAID setup utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup util...

Page 66: ...tility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAI...

Page 67: ...8 Miscellaneous Configuration Parameter Description Miscellaneous Configuration Active Video Selects the active video type Options available Auto Onboard Device PCIE Device Specific PCIE Device Defau...

Page 68: ...ays ME Firmware status information Current State Displays ME Firmware current status information Error Code Displays ME Firmware status error code Recovery Cause Displays ME Firmware recovery cause PT...

Page 69: ...nfigure advanced items WHEA Windows Hardware Error Architecture Support Enable Disable WHEA Support Options available Enable Disable Default setting is Enable Memory Error Enabling Press Enter to conf...

Page 70: ...te Enables and escalates Fatal Errors to error pins Options available Enable Disable Default setting is Enable Assert NMI on SERR Note Enable Disable BIOS generates a non maskable interrupt NMI and lo...

Page 71: ...p up the clock speed of 1 2 of its processing cores to improve its performance When this item is disabled the processor will not overclock any of its core Options available Enabled Disabled Default se...

Page 72: ...available Enabled Disabled Default setting is Enabled DCU Streamer Prefetcher Options available Enabled Disabled Default setting is Enabled Isoc Mode Enable Disable the Isochronous support in order to...

Page 73: ...g Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note2 Configures OS Watchdog Timer The value is between 1 to 30 mi...

Page 74: ...advanced items View FRU Information Press Enter to view the FRU information BMC VLAN Configuration Press Enter to configure advanced items BMC network Configuration Press Enter to configure advanced...

Page 75: ...se options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Eras...

Page 76: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Page 77: ...ration BMC VLAN ID Select to configure BMC VLAN ID The valid range is from 0 to 4094 When set to 0 BMC VLAN ID will be disabled BMC VLAN Priority Select to configure BMC VLAN Priority The valid range...

Page 78: ...lable Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP addres...

Page 79: ...network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by...

Page 80: ...l settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Page 81: ...the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen...

Page 82: ...Guard Ready Remove UEFI CA from DB Press Enter to remove Microsoft UEFI CA from Secure Boot DB Restore DB defaults Restore DB variable to factory defaults Secure Boot variable Displays the current st...

Page 83: ...abase Press Enter to configure a new DBT or load additional DBT from storage devices Options available Update Append OsRecovery Signatures Displays the current status of the OsRecovery Signature Datab...

Page 84: ...red values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Enabl...

Page 85: ...the boot order priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press...

Page 86: ...iscard Changes and Exit Discards changes made and exits the BIOS setup Options available Yes No Save Changes and Reset Restarts the system after saving the changes made Options available Yes No Discar...

Page 87: ...se settings the system might not function properly Options available Yes No Save as User Defaults Saves the changes made as the user default settings Options available Yes No Restore User Defaults Loa...

Page 88: ...ecovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 N...

Reviews: