CPU

 

Š

AMD EPYC™ 3151 SoC processor

 

Š

Single processor, 7nm, TDP 45W

 

Š

Processor Frequency: 2.7GHz-2.9GHz

 

Š

Up to 4-core, 8 threads per processor

 

Š

2MB L2 Cache, 16MB L3 Cache

Chipset

 

Š

System on Chip

Memory

 

Š

4 x DIMM slots

 

Š

DDR4 memory supported only

 

Š

Dual Channel memory architecture

 

Š

UDIMM, UDIMM ECC, RDIMM modules up to 128GB supported

 

Š

Memory speed: Up to 2666 MHz

Onboard 
Graphics 

 

Š

Integrated in Aspeed® AST2500

 

Š

2D Video Graphic Adapter with PCIe bus interface

 

Š

1920x1200@60Hz 32bpp

LAN

 

Š

2 x 1GbE LAN ports (Intel® I210-AT)

 

Š

1 x 10/100/1000 management LAN

Expansion Slots

 

Š

1 x PCIe x16 (Gen3 x16 bus) slot

Storage Interface

 

Š

1 x SlimSAS (with 4 x SATA 6Gb/s or PCIe Gen3 x4) connector

 

Š

4 x SATA 6Gb/s ports

 

Š

1 x M.2 slot:
- M-key
- PCIe Gen3 x4
- Supports NGFF-2280 cards

Internal I/O 
Connectors

 

Š

1 x 2 x 4-pin 12V power connector

 

Š

1 x 2 x 2-pin 5VSB/PSON power connector

 

Š

1 x SlimSAS connector

 

Š

1 x M.2 slot

 

Š

1 x CPU fan header

 

Š

2 x System fan headers

 

Š

1 x USB 3.0 header

 

Š

1 x COM1 header

 

Š

1 x Front panel header

 

Š

1 x IPMB connector

 

Š

1 x PMBUS connector

 

Š

1 x Clear CMOS jumper

Rear I/O 
Connectors

 

Š

2 x USB 3.0 

 

Š

1 x VGA 

 

Š

2 x RJ45

 

Š

1 x MLAN

 

Š

1 x POWER button with LED

 

Š

1 x ID button with LED

Summary of Contents for MJ11-EC0

Page 1: ...MJ11 EC0 AMD EPYC Embedded 3000 Series Processor Motherboard User Manual Rev 1 0...

Page 2: ...BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short gui...

Page 3: ...he Main Menu 26 2 2 Advanced Menu 29 2 2 1 Trusted Computing 30 2 2 2 PSP Firmware Versions 32 2 2 3 AST2500 Super IO Configuration 33 2 2 4 S5 RTC Wake Settings 35 2 2 5 Serial Port Console Redirecti...

Page 4: ...test points 90 2 8 7 Extended memory test point 90 2 8 8 Gnb Earlier init 91 2 8 9 PMU test points 94 2 8 10 ABL0 test points 94 2 8 11 ABL5 test points 94 2 9 Agesa POST Codes 98 2 9 1 Universal Pos...

Page 5: ...5 MJ11 EC0 Motherboard Layout DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_B0 DIMM_P0_B1 CPU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25...

Page 6: ...0 FP_1 Front Panel Header 11 BP_1 HDD Back Plane Board Connector 12 PMBUS PMBus Connector 13 DC_IN1 2x2 Pin 5VSB PSON Power Connector 14 SATA0 SATA III 6Gb s Connector 0 15 SATA1 SATA III 6Gb s Connec...

Page 7: ...7 Block Diagram...

Page 8: ...and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unp...

Page 9: ...1920x1200 60Hz 32bpp LAN 2 x 1GbE LAN ports Intel I210 AT 1 x 10 100 1000 management LAN Expansion Slots 1 x PCIe x16 Gen3 x16 bus slot Storage Interface 1 x SlimSAS with 4 x SATA 6Gb s or PCIe Gen3 x...

Page 10: ...ent Aspeed AST2500 management controller GIGABYTE Management Console AMI MegaRAC SP X web interface Form Factor Mini ITX 170W x 170D mm GIGABYTE reserves the right to make any changes to the product s...

Page 11: ...ord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to ins...

Page 12: ...vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module...

Page 13: ...oving the M 2 SSD Module Follow the steps below to install an optional M 2 SSD module on your motherboard Step1 Insert the M 2 SSD module into the slot Step2 Secure it with the screw tightening as nec...

Page 14: ...eeds of 10 100 1000Mbps This port is the dedicated LAN port for Server Management z USB 3 1 Ports The USB port supports the USB 3 0 specification Use this port for USB devices such as a USB keyboard m...

Page 15: ...lug the power cord from the power outlet to prevent damage to the devices After installing the device and before turning on the computer make sure the device cable has been securely attached to the co...

Page 16: ...nector in the correct orientation The 12V power connector mainly supplies power to the CPU If the 12V power connector is not connected the computer will not start To meet expansion requirements it is...

Page 17: ...SATA 3Gb s standard Each SATA connector supports a single SATA device 7 1 1 7 Pin No Definition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 7 SGPIO1 SATA SGPIO Connector Serial General Purpose Input Ou...

Page 18: ...l design For optimum heat dissipation it is recommended that a system fan be installed inside the chassis 4 Pin No Definition 1 GND 2 P12V 3 FAN_TACH 4 FAN_PWM Be sure to connect fan cables to the fan...

Page 19: ...nition 1 Power 11 IntA_P2_D 2 IntA_P1_SSRX 12 IntA_P2_D 3 IntA_P1_SSRX 13 GND 4 GND 14 IntA_P2_SSTX 5 IntA_P1_SSTX 15 IntA_P2_SSTX 6 IntA_P1_SSTX 16 GND 7 GND 17 IntA_P2_SSRX 8 IntA_P1_D 18 IntA_P2_SS...

Page 20: ...N 17 SMB_U2_TMP_SCL 18 GND 19 SMB_U2_TMP_SDA 20 I2C_DEV_RST 21 PH_HP_SCL0 22 GND 23 PH_HP_SDA0 24 GND 25 NC 26 GND 27 NC 28 GND 15 P3V3_AUX 30 P3V3_AUX 29 30 2 1 15 IPMB Intelligent Platform Managemen...

Page 21: ...ly consists of power switch reset switch power LED hard drive activity LED speaker etc When connecting your chassis front panel module to this header make sure the wire assignments and the pin assignm...

Page 22: ...attery voltage drops to a low level or the CMOS values may not be accurate or may be lost Always turn off your computer and unplug the power cord before replacing the battery Replace the battery with...

Page 23: ...23 Hardware Installation 1 7 Jumper Settings Jumper Name Jumper Setting Clear CMOS 1 2 Normal operation Default 2 3 Clear CMOS data Clear CMOS CLR_CMOS Default Enable 3 2 1...

Page 24: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Page 25: ...e set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setu...

Page 26: ...e Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item H...

Page 27: ...rsion information Processor Information CPU0 Brand String CPU Speed Processor Core Microcode Patch Displays the technical specifications for the installed processor s Total Memory Note2 Displays the t...

Page 28: ...PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note Displays LAN MAC address information LAN2 MAC Address Note Displays LAN MAC address information System Da...

Page 29: ...OS Setup 2 2 Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu s...

Page 30: ...banks Displays available Platform PCR banks SHA 1 PCR Bank Enable Disable SHA 1 PCR bank Options available Enabled Disabled Default setting is Enabled SHA256 PCR Bank Enable Disable SHA256 PCR bank Op...

Page 31: ...fault setting is Enabled TPM2 0 UEFI Spec Version Selects the TCG2 spec version support Options available TCG_1_2 TCG_2 Default setting is TCG2 Physical Presence Spec Version Selects the physical pres...

Page 32: ...BIOS Setup 32 2 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable...

Page 33: ...2 3 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration o...

Page 34: ...ble Enabled Disabled Default setting is Enabled Devices Settings Note2 Displays the Serial Port 1 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available...

Page 35: ...System from S5 Note Enable Disable system wake on alarm event Options available Disabled Fixed Time Dynamic Time When Fixed Time is selected system will wake on the hr min sec specified Default setti...

Page 36: ...0 Serial Over LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM0 Serial Over LAN Console Redirection is set to Enabled Termin...

Page 37: ...2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the...

Page 38: ...r remote management of a Windows Server OS through a serial port Options available COM0 SOL Default setting is COM0 SOL Terminal Type Selects a terminal type to be used for console redirection Options...

Page 39: ...CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is...

Page 40: ...ansion ROM for the related PCI E slot Options available Enabled Disabled Default setting is Enabled Onboard LAN 1 2 Controller Note1 Enable Disable the onboard LAN devices Options available Enabled Di...

Page 41: ...PCIe devices this item Enable Disable Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Disabled PCI E AER Enabled Enable Disable the PCI E AER Advanced Erro...

Page 42: ...t Enable Disable the Legacy USB support function AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Options av...

Page 43: ...ptions available 1 sec 5 sec 10 sec 20 sec Default setting is 20 sec Device reset time out Selects the time out value during a USB mass storage device reset Options available 10 sec 20 sec 30 sec 40 s...

Page 44: ...BIOS Setup 44 2 2 9 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system...

Page 45: ...45 BIOS Setup 2 2 10 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Page 46: ...ommon Options Press Enter for configuration of advanced items UMC Common Options Press Enter for configuration of advanced items NBIO Common Options Press Enter for configuration of advanced items FCH...

Page 47: ...rom each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Boost function Options available Auto Disabled Default setting...

Page 48: ...SMTEN Disable Single hardware thread per core Auto Two hardware threads per core Options available Disable Auto Default setting is Auto Streaming Stores Control Enable Disable the Streaming Stores fun...

Page 49: ...r Options available Auto Enabled Disabled Default setting is Auto GMI encryption control Enable Disable GMI link encryption Options available Auto Enabled Disabled Default setting is Auto xGMI encrypt...

Page 50: ...d not be used unless the interleaving is set to channel and the interleaving size is 256 or 512 bytes Options available Auto Enabled Disabled Default setting is Auto Memory Clear Enable Disable the Me...

Page 51: ...ns Parameter Description UMC Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items Memory MBIST Press E...

Page 52: ...rclock Settings Options available Auto Enabled Default setting is Auto DRAM Controller Configuration Press Enter for configuration of advanced items DRAM Power Options Power Down Enable Enable Disable...

Page 53: ...Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable...

Page 54: ...how applications get assigned to physical locations within the memory modules When this option sets to Auto it is null No help string Options available Auto Enabled Disabled Default setting is Auto B...

Page 55: ...ce Mode Interface Mode Tests Single and Multiple CS transactions and Basic Connectivity Data Eye Mode Measures Voltage vs Timing MBIST Aggressors Note Enable Disable MBIST Aggressor test Options avail...

Page 56: ...NBIO Internal Poison Consumption Options available Auto Enabled Disabled Default setting is Auto NBIO RAS Control Enable Disable NBIO RAS Control Options available Auto Enabled Disabled Default settin...

Page 57: ...Default setting is Auto CRS Delay Set the CRS delay for hot plug ports CRS Limit Set the CRS limit for hot plug ports Hot Plug flags Press Enter for configuration of advanced items Ignore sideband Ena...

Page 58: ...tion Enable Disable Sata Disabled AHCI Prefetch Function Options available Auto Enabled Disabled Default setting is Auto Aggressive SATA Device Sleep Port 0 Options available Auto Enabled Disabled Def...

Page 59: ...5 Enable Enable Disable I2C 0 1 2 3 4 5 Options available Auto Enabled Disabled Default setting is Auto Uart Configuration Options Press Enter for configuration of advanced items Uart 0 Enable Uart 0...

Page 60: ...Driver Type Bios will select MS driver for SD selections Options available AMD eMMC Driver MS Driver MS EMMC Driver Auto Default setting is Auto eMMC Boot Options available Disabled Enabled Auto Defa...

Page 61: ...ocket1 Die3 Default setting is Auto NTB active on PCIeCore Note NTB enable on PCIe Core Options available Auto Core0 Core1 Default setting is Auto NTB Mode Note Selects NTB Mode Core0 Port0 Options av...

Page 62: ...etting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature O...

Page 63: ...nitiator Name Press Enter and name iSCSI Initiator Only IQN format is accepted Range from 4 to 223 Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure advan...

Page 64: ...guration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Page 65: ...65 BIOS Setup 2 2 15 Intel R I210 Gigabit Network Connection...

Page 66: ...Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network...

Page 67: ...67 BIOS Setup 2 2 16 VLAN Configuration...

Page 68: ...he keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired...

Page 69: ...ote Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gatewa...

Page 70: ...BIOS Setup 70 2 2 18 MAC IPv6 Network Configuration...

Page 71: ...string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address...

Page 72: ...1T single thread Auto 2T two thread if capable Options available Off Auto Default setting is Auto PCIe Link Training Type Configures the PCIe Link training in 1 or 2 steps Options available 1 Step 2 S...

Page 73: ...p 2 3 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information Socket 0 Information Press Enter to view information related...

Page 74: ...bled Disabled Default setting is Disabled Max Parity Error Replay Note1 Sets the max parity error replay Valid range 2 to 8 DRAM Write Data CRC with Replay Write CRC Enable Options available Enabled D...

Page 75: ...t Power Down Default setting is Do Nothing Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available E...

Page 76: ...minutes 4 minutes 6 minutes Default setting is 10 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configurati...

Page 77: ...se SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do N...

Page 78: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Page 79: ...tions available Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the...

Page 80: ...ork during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIO...

Page 81: ...l settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Page 82: ...ions that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not bee...

Page 83: ...osoft UEFI CA from Secure Boot DB Restore DB defaults Restore DB variable to factory defaults Secure Boot variable Displays the current status of the variables used for secure boot Platform Key PK Dis...

Page 84: ...base Press Enter to configure a new DBT or load additional DBT from storage devices Options available Update Append OsRecovery Signatures Displays the current status of the OsRecovery Signature Databa...

Page 85: ...definite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Di...

Page 86: ...tion UEFI USB Drive BBS Priorities Press Enter to configure the boot priority UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter...

Page 87: ...e so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of r...

Page 88: ...0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public interf...

Page 89: ...BL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Inte...

Page 90: ...init 0xE057 Exit point CPU APOB EDC info init 0xE058 2 8 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 2 8 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3 0x...

Page 91: ...e 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug cod...

Page 92: ...Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGM...

Page 93: ...AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allo...

Page 94: ...itialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchroni...

Page 95: ...DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for He...

Page 96: ...rror 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted...

Page 97: ...30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Er...

Page 98: ...7 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTraini...

Page 99: ...Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Chan...

Page 100: ...A187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For...

Page 101: ...code calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate...

Page 102: ...V2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save ar...

Page 103: ...and MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mai...

Page 104: ...0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910...

Page 105: ...NbioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0...

Page 106: ...ate exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 2 9 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX d...

Page 107: ...finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 FC...

Page 108: ...xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH Ini...

Page 109: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 2 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the A...