GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
*0270 Real time clock error
Real-Time Clock fails BIOS hardware test. May require board repair.
0271 Check date and time settings
BIOS found date or time out of range and reset the Real-Time Clock. May require setting legal
date (1991-2099).
0280 Previous boot incomplete - Default configuration used
Previous POST did not complete successfully. POST loads default values and offers to run
Setup. If the failure was caused by incorrect values and they are not corrected, the next boot
will likely fail. On systems with control of wait states, improper Setup settings can also
terminate POST and cause this error on the next boot. Run Setup and verify that the waitstate
configuration is correct. This error is cleared the next time the system is booted.
0281 Memory Size found by POST differed from CMOS
Memory size found by POST differed from CMOS.
02B0 Diskette drive A error
02B1 Diskette drive B error
Drive A: or B: is present but fails the BIOS POST diskette tests. Check to see that the drive is
defined with the proper diskette type in Setup and that
the diskette drive is attached correctly.
02B2 Incorrect Drive A type - run SETUP
Type of floppy drive A: not correctly identified in Setup.
02B3 Incorrect Drive B type - run SETUP
Type of floppy drive B: not correctly identified in Setup.
02D0 System cache error - Cache disabled
RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers.
You may have to replace the cache. See your dealer. A disabled cache slows system
performance considerably.
02F0: CPU ID:
CPU socket number for Multi-Processor error.
*02F4: EISA CMOS not writeable
ServerBIOS2 test error: Cannot write to EISA CMOS.
*02F5: DMA Test Failed
ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers.
*02F6: Software NMI Failed
ServerBIOS2 test error: Cannot generate software NMI (Non-Maskable Interrupt).
*02F7: Fail-Safe Timer NMI Failed
ServerBIOS2 test error: Fail-Safe Timer takes too long.
Device Address Conflict
Address conflict for specified device.
Allocation Error for: device
Run ISA or EISA Configuration Utility to resolve resource conflict for the specified device.
CD ROM Drive
CD ROM Drive identified.
Summary of Contents for GS-R22T61
Page 19: ...19 GS R22T61 RH GS R22T81 RH Rack Mount Server 4 5 ...
Page 21: ...21 GS R22T61 RH GS R22T81 RH Rack Mount Server 4 5 5 6 7 7 7 ...
Page 51: ...51 GS R22T61 RH GS R22T81 RH Rack Mount Server Processor Configuration ...
Page 58: ...58 BIOS Setup Memory Configuration ...
Page 60: ...60 BIOS Setup Advanced Chipset Configuration ...
Page 61: ...61 GS R22T61 RH GS R22T81 RH Rack Mount Server Figure 2 3 1 Intel VT for Directed I O VT d ...
Page 66: ...66 BIOS Setup SATA Configuration Figure 2 5 SATA Configuration ...
Page 79: ...79 GS R22T61 RH GS R22T81 RH Rack Mount Server Server Figure 5 Server ...
Page 80: ...80 GS R22T61 RH GS R22T81 RH Rack Mount Server System Management Figure 5 1 System Management ...