2 4
GS-R1271-RH Rack Mount Server
1. CLR_CMOS ( (Clear CMOS jumper)
You may clear the CMOS data to its default values by this jumper.
Default value doesn’t include the “Shunter” to prevent from improper use this jumper.
To clear CMOS, temporarily short 2-3 pin.
2. PWR_JP1 (Front panel USB1 power source selection jumper)
1-2 Close: Normal operation (Default setting)
2-3 Close: Clear CMOS
1
1
1
1
1-2 Close: 5V_AUX
2-3 Close: 5V
3. PILOT_DIS (Pilot II BMC Function Enable/Disable jumper)
1
1
1-2 Close: Enable Pilot II BMC function
2-3 Close: Disable Pilot II BMC function
4. BMC_SEL1 (BMC Firmware area selection)
1
1
1-2 Close: Select BMC firmware in bank0
2-3 Close: Select BMC firmware in bank1
5. SPI_WP1 (SPI BIOS write protection Disable/Enable jumper)
1-2 Close: Select BMC firmware in bank0
2-3 Close: Select BMC firmware in bank1
1