PC Health Status
&
Reset Case Open Status
Disabled
Keeps or clears the record of previous chassis intrusion status. (Default)
Enabled
Clears the record of previous chassis intrusion status and the
Case Open
field will
show "No" at next boot.
&
Case Open
Displays the detection status of the chassis intrusion detection device attached to the motherboard CI
header. If the system chassis cover is removed, this field will show "Yes", otherwise it will show "No". To
clear the chassis intrusion status record, set
Reset Case Open Status
to
Enabled
, save the settings to
the CMOS, and then restart your system.
&
CPU Vcore/CPU VCCSA/DRAM Channel A/B V3.3V/+5V/+12V/CPU VAXG
Displays the current system voltages.
&
CPU/System/PCH/VRM MOS
Displays current CPU/system temperature.
&
CPU/System 1 Fan Speed
Displays current CPU/system fan speeds.
&
CPU/System 1/PCH/VRM MOS Temperature
Sets the warning threshold for CPU/System/PCH/VRM MOS temperature. When temperature exceeds
the threshold, BIOS will emit warning sound. Options are: Disabled (default), 60
o
C/140
o
F, 70
o
C/158
o
F,
80
o
C/176
o
F, 90
o
C/194
o
F.
&
CPU/System 1 Fan Fail Warning
Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan
connection when this occurs. (Default: Disabled)
&
Fan Control Mode
Auto
Lets the BIOS automatically detect the type of fan installed and sets the optimal control
mode. (Default)
Voltage
Voltage mode is recommended for a 3-pin fan.
PWM
PWM mode is recommended for a 4-pin fan.
&
Fan Speed Control
Allows you to determine whether to enable the fan speed control function and adjust the fan speed.
Normal
Allows the fan to run at different speeds according to the CPU temperature. (Default)
Silent
Allows the fan to run at slow speeds.
Manual
Allows you to control the fan speed under the
Fan Speed Percentage
item.
Full Speed
Allows the fan to run at full speeds.
&
Fan Speed Percentage
Allows you to control the fan speed. This item is configurable only when
Fan Speed Control
is set to
Manual
. Options are: 0.75 PWM value /
o
C ~ 2.50 PWM value /
o
C.
&
Fan Control Use Temperature Input
Allows you to select the reference temperature for fan speed control.
&
Temperature Interval
Allows you to select the temperature interval for fan speed change.
- 25 -