background image

Manual 07507014 

Model 7014 

Page 4 

 

O

peration Manual

 

 

Record of Changes to This Manual 

Use the table below to maintain a permanent record of changes to this document. Corrected 
replacement pages are issued as Technical Publication Change Instructions (TPCI). When you 
are issued a TPCI, do the following: 

1.  Insert the TPCI at the front of the manual binder. 

2.  Remove the pages from the manual binder that are noted in the TPCI. 

3.  Replace the page(s) removed in the previous step with the corrected page(s). 

4.  Record the changes in the table below. 

 

TPCI 

Number 

TPCI Issue 

Date 

Date Entered 

Comments 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ASCOR 7014

Page 1: ...Manual 07507014 Model 7014 Page 1 Operation Manual Model 7014 4 1x4 1 wire Multiplexers 91000050 ...

Page 2: ...925 328 4700 On the Internet www gigatronics com Warranty Giga tronics Series 7000 Switching Modules are warranted against defective materials and workmanship for three years from date of shipment or as detailed in the warranty section of this manual Giga tronics will at its option repair or replace products that are proven defective during the warranty period This warranty DOES NOT cover damage r...

Page 3: ...N61010 1 1993 Electrical Safety EN61326 1 1997 EMC Emissions and Immunity Manufacturer s Name Manufacturer s Address Giga tronics Incorporated 4650 Norris Canyon Road San Ramon California 94583 U S A Type of Equipment Model Series Number Switching Module 7014 Declaration of Conformity on file Contact Giga tronics at the following Giga tronics Incorporated 4650 Norris Canyon Road San Ramon Californ...

Page 4: ... are issued as Technical Publication Change Instructions TPCI When you are issued a TPCI do the following 1 Insert the TPCI at the front of the manual binder 2 Remove the pages from the manual binder that are noted in the TPCI 3 Replace the page s removed in the previous step with the corrected page s 4 Record the changes in the table below TPCI Number TPCI Issue Date Date Entered Comments ...

Page 5: ...Manual 07507014 Model 7014 Page 5 Operation Manual Revision History Revision Description of Change Chg Order Approved By A Initial Release 2 02 JL B Updated C Reformatted 5 12 RCW ...

Page 6: ...ent Safety Alert 7 1 1 4 Notes 7 1 1 5 Electrical Safety Precautions 7 Chapter 2 Configuration Table Error Bookmark not defined Chapter 3 Functional Description 9 3 1 Introduction 9 3 2 General Description Error Bookmark not defined Chapter 4 Block Diagram 10 Chapter 6 Specifications 11 Chapter 7 Register Map Error Bookmark not defined Chapter 8 Front Panel Connector Pins Error Bookmark not define...

Page 7: ...njury 1 1 3 Equipment Safety Alert CAUTION Indicates a situation which can damage or adversely affect the product or associated equipment 1 1 4 Notes Notes are denoted and used as follows NOTE Highlights or amplifies an essential operating or maintenance procedure practice condition or statement 1 1 5 Electrical Safety Precautions Any servicing instructions are for use by service trained personnel...

Page 8: ...Manual 07507014 Model 7014 Page 8 Operation Manual Chapter 2 Configuration Table Module PL9100050 Assy91000050 Assembly Schematics PL85002610 Assy85002610 SCH85002610 ...

Page 9: ...s card assembly contains four 1x4 1 wire multiplexers The card assembly complies with National Instrument PXI specification which allows ease of design of complex switch systems This card assembly can be configured by program into the following configurations One 1x16 multiplexer Two 1x8 multiplexers Quad 1x4 multiplexers ...

Page 10: ...D CH 1 SHLD CH 2 1x4 Input SHLD SHLD CH 3 SHLD CH 4 SHLD CH 1 SHLD CH 2 1x4 Input SHLD SHLD CH 3 SHLD CH 4 SHLD CH 1 SHLD CH 2 SHLD CH 3 SHLD CH 4 SHLD CH 1 SHLD CH 2 1x4 Input SHLD SHLD CH 3 SHLD CH 4 SHLD CH 1 SHLD CH 2 1x4 Input SHLD SHLD CH 3 SHLD CH 4 1x8 Input SHLD 1x8 Input SHLD 1x16 Input SHLD Analog Groundplane ...

Page 11: ... VACpk Min mech life expectancy 1B cycles Initial Contact Resistance 250mΩ Mechanical Size 3U PXI Width 0 8 inches Height 5 2 inches Length 6 5 inches Weight 0 5 lbs J1 J2 connectors AMP TYCO 104129 9 Mating Connectors ASCOR Installation Kit P N 89800700 Environmental Specifications Temperature Operating 0º to 55ºC Storage 40º to 75ºC Relative Humidity Operating 0 to 90 non condensing Storage 0 to...

Page 12: ...lled the relay coil The register map is organized to show the relay designation in each register PXI will automatically assign the starting address of the card called Bar0 This will be the starting address of the first register Each address location controls 8 bits Shown are the control functions using 16 format Programming of the Model 7014 is very straight forward The module is organized as a 1 ...

Page 13: ...0 39 1x8 A Common 1x4 B Shield 38 37 1x4 B Common Shield 36 35 PIN 1B Shield 34 33 PIN 2B Shield 32 31 PIN 3B Shield 30 29 PIN 4B 1x16 Shield 28 27 1x16 Common Shield 26 25 PIN 1C Shield 24 23 PIN 2C Shield 22 21 PIN 3C Shield 20 19 PIN 4C 1x4 C Shield 18 17 1x4 C Common 1x8 B Shield 16 15 1x8 B Common 1x4 D Shield 14 13 1x4 D Common Shield 12 11 PIN 1D Shield 10 9 PIN 2D Shield 8 7 PIN 3D Shield ...

Reviews: