Series 8650A Universal Power Meters
3-100
Manual 31470, Rev. E, April 2001
3.18.6
Measurement Mode Query
It is possible to query the 8650A over the bus to determine what measurement mode has been selected
for a particular sensor. The 8650A will respond to a measurement mode query by returning one of the
following strings to the controller:
NO SENSOR
UNCAL
CW
MAP (or MAP SYNC OFF)
1
PAP
PEAK
BAP (or BAP
a b c)
2
Measurement mode query commands are based on the MEAS function code:
Notes:
1.
MAP SYNC OFF will be returned if MAP mode synchronization has been disabled.
2.
BAP
a b c
will be returned if any of the advanced features have been enabled. In this message, a represents the burst start
exclude time in ms, b represents the burst end exclude time in ms, and c represents burst dropout time in ms. The value
ranges are 0.000
≤
a
≤ 45.548;
0.000
≤
b
≤
31.949;0.000
≤
c
≤
3.747
Syntax
:
MEAS [A? or B?]
[A? or B?] specifies Sensor A or Sensor B.
Examples
:
OUTPUT 713;MEAS A?
! queries the measurement mode setting for sensor A
OUTPUT 713;MEAS B?
! queries the measurement mode setting for sensor B
Summary of Contents for 8650A Series
Page 4: ......
Page 12: ...Series 8650A Universal Power Meters viii Manual 31470 Rev E April 2001 ...
Page 16: ...Series 8650A Universal Power Meters xii Manual 31470 Rev E April 2001 ...
Page 18: ...Series 8650A Universal Power Meters xiv Manual 31470 Rev E April 2001 ...
Page 20: ...Series 8650A Universal Power Meters xvi Manual 31470 Rev E April 2001 ...
Page 32: ...Series 8650A Universal Power Meters 1 12 Manual 31470 Rev E April 2001 ...
Page 198: ...Series 8650A Universal Power Meters 3 124 Manual 31470 Rev E April 2001 ...
Page 216: ...Series 8650A Universal Power Meters A 8 Manual 31470 Rev E April 2001 ...
Page 228: ...Series 8650A Universal Power Meters B 12 Manual 31470 Rev E April 2001 ...
Page 240: ...Series 8650A Universal Power Meters Index 6 Manual 31470 Rev E April 2001 ...