background image

Manual

 

07504353

   

Model

 

3000

4353

 

Chapter 5

 

Controls and Indicators 

The

 

following

 

controls

 

and

 

indicators

 

are

 

provided

 

to

 

select

 

and

 

display

 

the

 

functions

 

of

 

the

 

ASCOR

 

3000

4353

 

Module’s

 

operating

 

environment.

 

5.1

 

VXI

 

Logical

 

Address

 

The

 

Logical

 

Address

 

Switch

 

is

 

dual

 

circular

 

switches,

 

D1

 

and

 

D2

 

which

 

are

 

located

 

at

 

the

 

rear

 

of

 

the

 

module.

 

The

 

address

 

can

 

be

 

set

 

to

 

any

 

value

 

between

 

1

 

and

 

255

 

(decimal)

 

or

 

1

 

and

 

FF

 

(hexadecimal),

 

(address

 

0

 

is

 

reserved

 

for

 

the

 

resource

 

manager).

 

However,

 

the

 

Module

 

fully

 

supports

 

Dynamic

 

Configuration

 

as

 

defined

 

in

 

Section

 

F

 

of

 

the

 

VXI

 

specification,

 

address

 

255

 

(FF)

 

should

 

be

 

selected

 

only

 

if

 

the

 

Resource

 

Manager

 

also

 

supports

 

Dynamic

 

Configuration.

 

 

 

5.2

 

LEDs

 

The

 

following

 

LEDs

 

are

 

visible

 

at

 

the

 

Module’s

 

front

 

panel

 

to

 

indicate

 

the

  

status

 

of

 

the

 

module’s

 

operation:

 

 

5.2.1

 

“BUS”

 

LED

 

This

 

green

 

color

 

LED

 

is

 

normally

 

off

 

and

 

will

 

flash

 

on

 

when

 

the

 

module

 

is

 

addressed

 

by

 

the

 

system.

 

5.2.2

 

“PWR”

 

LED

 

This

 

red

 

color

 

LED

 

is

 

normally

 

on

 

when

 

the

 

Module

 

is

 

Powered

 

up.

 

Page

 

11

 

 

O

peration

 

Manual

 

 

Summary of Contents for 3000-4353

Page 1: ...Manual 07504353 Model 3000 4353 Model 3000 4353 32 SPST Switch Module 90401310 Page 1 Operation Manual ...

Page 2: ...nual Giga tronics will at its option repair or replace products that are proven defective during the warranty period This warranty DOES NOT cover damage resulting from improper use nor workmanship other than Giga tronics service There is no implied warranty of fitness for a particular purpose nor is Giga tronics liable for any consequential damages Specification and price change privileges are res...

Page 3: ...N61010 1 1993 Electrical Safety EN61326 1 1997 EMC Emissions and Immunity Manufacturer s Name Manufacturer s Address Giga tronics Incorporated 4650 Norris Canyon Road San Ramon California 94583 U S A Type of Equipment Model Series Number Switching Module 3000 4353 Declaration of Conformity on file Contact Giga tronics at the following Giga tronics Incorporated 4650 Norris Canyon Road San Ramon Cal...

Page 4: ...es are issued as Technical Publication Change Instructions TPCI When you are issued a TPCI do the following 1 Insert the TPCI at the front of the manual binder 2 Remove the pages from the manual binder that are noted in the TPCI 3 Replace the page s removed in the previous step with the corrected page s 4 Record the changes in the table below TPCI Number TPCI Issue Date Date Entered Comments ...

Page 5: ...Manual 07504353 Model 3000 4353 Page 5 Operation Manual Revision History Revision Description of Change Chg Order Approved By Initial Release A Updated 6 02 B Updated 2 08 C Reformatted 3 12 RCW ...

Page 6: ...nfiguration Table 8 Chapter 3 Functional Description 9 3 1 Introduction 9 3 2 General Description 9 Chapter 4 Front Panel 10 Chapter 5 Controls and Indicators 11 5 1 VXI Logical Address 11 5 2 LEDs 11 5 2 1 BUS LED 11 5 2 2 PWR LED 11 Chapter 6 Internal Settings 12 6 1 Fuse 12 6 2 J105 12 6 3 J107 Error Bookmark not defined 6 4 J106 Error Bookmark not defined 6 5 VXIbus Interrupt Level Selection 1...

Page 7: ...quipment Safety Alert CAUTION Indicates a situation which can damage or adversely affect the product or associated equipment CAUTION 1 1 4 Notes Notes are denoted and used as follows NOTE Highlights or amplifies an essential operating or maintenance procedure practice condition or statement 1 1 5 Electrical Safety Precautions Any servicing instructions are for use by service trained personnel only...

Page 8: ...04353 Model 3000 4353 Page 8 Operation Manual Chapter 2 Configuration Table TOP ASSEMBLY PL 90401310 ASM 90401310 PL 85003950 001 ASM 85003950 001 SCH 85003950 001 PL PARTS LIST ASM ASSEMBLY DRAWING SCH SCHEMATIC ...

Page 9: ...ule VX4353 Each relay is independently controlled and can be independently opened or closed under program control 3 2 General Description The 3000 4353 is a direct hardware replacement for the Tektronix VX4353 The same front panel connectors the same signals come to the same pins and the specifications are the same or better No special cables or adapter are necessary ASCOR also provides a software...

Page 10: ...Manual 07504353 Model 3000 4353 Chapter 4 Front Panel Page 10 Operation Manual ...

Page 11: ... 1 and FF hexadecimal address 0 is reserved for the resource manager However the Module fully supports Dynamic Configuration as defined in Section F of the VXI specification address 255 FF should be selected only if the Resource Manager also supports Dynamic Configuration 5 2 LEDs The following LEDs are visible at the Module s front panel to indicate the status of the module s operation 5 2 1 BUS ...

Page 12: ...OR VXI 3000 4353 uses a 5 Amp fuse in the 5 Volt line and a 5 A fuse in the 12 Volt line If any fuse opens remove the fault before replacing the fuse to avoid any other damage 6 2 VXIbus Interrupt Level Selection The VXIbus interrupt level is set with three bits in the 3Eh register See the section on A16 ADDRESS SPACE REGISTER DESCRIPTION The interrupt level is factory set to no interrupt ...

Page 13: ...mum switching rate is 4 milliseconds minimum Signal Path Specifications Signal path resistance Initial 0 3 oHMS Insulation resistance 10 Gigaohms Isolation Wiper to Open Contact 18 dB at 1 MHz Cross talk between Channels 40 dB at 1 MHz Power up Condition At power up all relays are reset Open Operational Life 5 X 10e6 VXI Compatibility Fully compatible with VXI Specification REV 1 0 VXI Device Type...

Page 14: ...Manual VXI Bus Radiated Emissions Complies with VXIbus Specification VXI Bus Conducted Emissions Complies with VXIbus Specification Dimensions VXI C size 10 3in x 13 8in x 1 2in Weight 3 lbs Front Panel Connectors 50 Position PC Mount Tyco AMP 206971 2 ...

Page 15: ...FFC hex typical after running Resource Manager In order to reset the module read this address set bit 0 high then set bit 0 low without altering the other bits Control Bit 3Eh 0 Low true output enable to the coil driver ICs 1 When low enables read back of the coil state When high enables read back of the data registers 2 Leave set to 0 reserved by Ascor 3 Interrupt bit 0 LSB Used to set the Module...

Page 16: ...0 0 K2 1 1 K3 2 2 K4 3 3 K5 4 4 K6 5 5 K7 6 6 K8 7 7 K9 8 8 K10 9 9 K11 10 10 K12 11 11 K13 12 12 K14 13 13 K15 14 14 K16 15 15 REGISTER REGISTER 8002h 8000h RELAY 16 BIT 32 BIT K17 0 16 K18 1 17 K19 2 18 K20 3 19 K21 4 20 K22 5 21 K23 6 22 K24 7 23 K25 8 24 K26 9 25 K27 10 26 K28 11 27 K29 12 28 K30 13 29 K31 14 30 K32 15 31 ...

Page 17: ... 15 K9 P4 19 P4 18 K10 P4 21 P4 20 K11 P4 23 P4 22 K12 P4 25 P4 24 K13 P4 27 P4 26 K14 P4 29 P4 28 K15 P4 31 P4 30 K16 P4 33 P4 32 K17 P5 2 P5 1 K18 P5 4 P5 3 K19 P5 6 P5 5 K20 P5 8 P5 7 K21 P5 10 P5 9 K22 P5 12 P5 11 K23 P5 14 P5 13 K24 P5 16 P5 15 K25 P5 19 P5 18 K26 P5 21 P5 20 K27 P5 23 P5 22 K28 P5 25 P5 24 K29 P5 27 P5 26 K30 P5 29 P5 28 K31 P5 31 P5 30 K32 P5 33 P5 32 P4 17 50 AGND P5 17 50...

Reviews: