background image

 

15

2.

 

Click [Convert Table] and add a card to the table. 

 

   

 
 
 
 
 
 

 

Card ID

: If [Card ID] checkbox is checked, it indicates the card number will be 

converted to the string you set. If [Card ID] checkbox is unchecked, it 
indicates the card number will not be converted. 
 

 

Read

: When you put a card on PCR340, the card number and card type will 

be shown in the boxes if you click [Read]. 
 

 

AutoRead

: If [AutoRead] checkbox is checked, when you put a card on 

PCR340, the card number and card type will be shown in the boxes 
automatically.   
 

 

You can enter the card number and select [Card Type] manually without 
putting the card on PCR340. 
 

 

Output

: Enter the string you want the card number to be converted in 

[Output] box. 
 

 

Add

: Click [Add] to add the setting for the card number to the table. 

 
 

After clicking [Write] and then putting 
the card on PCR340, it will get: 

Summary of Contents for PCR340 Series

Page 1: ...PCR340 Series Dual Frequency RFID Reader Manual Part Number TM951119 REV E 2017 ...

Page 2: ...cation 3 Accessories 4 Getting Started 5 Pin Assignment and Connection 6 Important Instructions 9 Installing USB Driver for PCR340 VC 10 Configuring PCR340 with the Configuration Software 10 Command and Packet Format 19 ...

Page 3: ...9dBuV m Reading distance 50 mm 125KHz 40 mm 13 56MHz Baud rate 19200 14400 9600 4800 2400 bps Settings N 8 1 PCR340 00 USB USB HID Keyboard PS 2 RS232 Interface PCR340 VC USB USB RS232 the virtual serial port PS 2 RS232 Power requirement DC 5V 150mA Standby 70mA Certificate CE FCC Dimension 120 L x 86 W x 42 H mm Weight 150g Operating temperature 0 to 50 degree C Storage temperature 10 to 60 degre...

Page 4: ...ower Cable WAS 1536A PS 2 Cable WAS T0044 USB Cable WAS T0043 Note When WAS T0043 is connected to PCR340 00 the interface will work as USB HID Keyboard when WAS T0043 is connected to PCR340 VC the interface will work as USB RS232 the virtual serial port and it needs to install USB driver see p 10 ...

Page 5: ...ou can use the external power supply DC5V for RS232 connection Reaction panel Put the card on reaction panel to read the card information Status LED Status Green LED Red LED Yellow LED Read Card Power on Blink twice Blink twice Blink twice X Ready Off On Off X Read ok Blink once On Off O Firmware Management mode Off Off On X ...

Page 6: ...signment and Connection WAS T0042 pin assignment DB9 FEMALE PIN FUNCATION PIN2 RX PIN3 TX PIN5 GND Connection DC 5V 150mA PHONE PLUG PIN FUNCATION PIN5 TX PIN6 RX PIN7 VDD PIN10 GND CABLE P N WAS XXXX REV X 1 1 ...

Page 7: ...7 WAS T0043 pin assignment USB PLUG PIN FUNCTION PIN1 VDD PIN2 D PIN3 D PIN4 GND Connection PHONE PLUG PIN FUNCTION PIN7 VDD PIN8 D PIN9 D PIN10 GND CABLE P N WAS XXXX REV X 1 1 ...

Page 8: ...XX REV X Connection PIN NUMBER PHONE PLUG PIN MINI DIN MALE PIN KB FEMALE PIN PIN1 KB_CLOCK CLOCK PIN5 PIN2 PC_CLOCK CLOCK PIN5 PIN3 PC_DATA DATA PIN1 PIN4 KB_DATA DATA PIN1 PIN5 PIN6 PIN7 5V 5V PIN4 5V PIN4 PIN8 PIN9 PIN10 GND GND PIN3 GND PIN3 ...

Page 9: ...FID readers at about 50 cm while PCR340 is under the operation to avoid the interference 2 Once continuous card reading is completed wait for a while until Green LED goes off to access the next card reading 3 Before starting your computer do not put RFID card on the reaction panel to avoid the error ...

Page 10: ...l USB driver Configuring PCR340 with the Configuration Software The configuration software PCR340Setup_version_PSW00058 exe is in the bundled disk Install the software first Connect PCR340 with your computer through RS232 port and then run the software Note 1 To connect PCR340 00 with our software it allows you to use RS232 cable only If you use USB cable or PS 2 cable the software will not be abl...

Page 11: ...11 The main page of the configuration software Information display area Function keys Product information Functional setting tabs ...

Page 12: ...ssage and the product information as below Step 2 MISC Click MISC Set BaudRate Language Keyboard type and Using code matching to right numeral part of keyboard if necessary Then click Write to save the settings to PCR340 If the baudrate is changed power off PCR340 first and the new baudrate will work after PCR340 is powered on again ...

Page 13: ...e settings to PCR340 Step 4 Format Click Format Set Prefix code Postfix code OnRemove message and Delimiter if necessary If you want PCR340 to send the card type when the card is read check Display Card Type checkbox Then click Write to save the settings to PCR340 Drag start end to change the range 1K card type Select Hex Dec Filter Select the output in MSB or LSB Select the output in Hex or Dec ...

Page 14: ...vert Table If you want PCR340 to show alphabetical string instead of card number click Convert Table to edit the message you like by the following procedures 1 Click Format and check Output by String Table checkbox ...

Page 15: ...rd type will be shown in the boxes if you click Read AutoRead If AutoRead checkbox is checked when you put a card on PCR340 the card number and card type will be shown in the boxes automatically You can enter the card number and select Card Type manually without putting the card on PCR340 Output Enter the string you want the card number to be converted in Output box Add Click Add to add the settin...

Page 16: ...ou want to edit and change the setting and then click Modify if you want to edit the setting 4 Select the item you want to delete from the table and then click Remove if you want to remove it Select the item Select the item ...

Page 17: ...Save Click Save to save all settings as a txt file if necessary Step 7 Open If you want to load the settings form the file to PCR340 click Open to open the file and then click Write to load the settings to PCR340 ...

Page 18: ...em Description Baud Rate 19200 bps Settings N 8 1 Language USA Using code matching to right numeral part of keyboard Disable Prefix Empty Postfix Empty OnRemove Empty Delimiter CR LF Display Card Type Disable Output by String Table Disable Card Type Numeric System From Character Number of Characters HEX 1 8 Mifare 1K DEC 1 10 HEX 1 8 Mifare 4K DEC 1 10 HEX 1 14 UltraLight DEC 1 18 HEX 1 14 DesFire...

Page 19: ...aracter 1 character 1 character Functional command ITEM Dec Hex Function STX 2 02 Start for test CMD ASCII ASCII Command code CONTENTS ASCII ASCII Contents data CHECKSUM ASCII ASCII Check sum REPLY 65 41 Acknowledge CR 13 0D Carriage return Instruction command Command ASCII Description C 43H Set Register B 42H Get Register V 56H Get Firmware Version D 44H Get Product Name X 58H ISP Mode Y 59H Show...

Page 20: ...r index Description Access LEVEL 00 Access Denied or Password Error 01 Command packet is too long 02 Command packet is empty 03 Command code is out of range COMMAND CODE 04 Illegal Command or Data 05 Database and Register is Empty 06 Record number is out of range 07 Check Sum Error 08 Memory Not Enough DATABASE 09 Action Failure FILE 0A File Not Exist ...

Page 21: ...e PC PCR340 02 B 00 0D PC PCR340 02 A FF CD 0D Get F W version V 56H PC PCR340 STX V CR PC PCR340 STX ACK Firmware number Firmware version CR Firmware number ROM Txxxx Firmware version Vx xxrm Vx xx Firmware version rm Modification frequency For Instance PC PCR340 02 V 0D PC PCR340 02 A ROM T0611 V1 00R2 0D Get Product name D 56H PC PCR340 STX D CR PC PCR340 STX ACK Product name Keyboard language ...

Page 22: ... PC PCR340 STX X CR PC PCR340 STX A CR For Instance PC PCR340 02 X 0D PC PCR340 02 A 0D Show memory data Y 59H PC PCR340 STX Y CR PC PCR340 STX Register Table CR For Instance PC PCR340 02 Y 0D PC PCR340 02 Register Table 0D ...

Page 23: ...th 1 8 0E4h 0E5h Mifare Ultralight MF0 ICS70 Card ID Filter Register 0E4h Start Register 0E5h Length ID Filter Range 1 Start Length 1 14 0E6h 0E7h Mifare DESFire MF3 ICD40 Card ID Filter Register 0E6h Start Register 0E7h Length ID Filter Range 1 Start Length 1 14 0E8h 0E9h 125KHZ EM Card Card ID Filter Register 0E8h Start Register 0E9h Length ID Filter Range 1 Start Length 1 10 New added functions...

Page 24: ...ce 00 FEh Output Card ID in LSB first sequence 089h 125KHZ EM Card ID Sequence FFh Output Card ID in MSB first sequence 00 FEh Output Card ID in LSB first sequence New added functions of the latest version V1 01R7 Register Address Function Description 0D0h Delimiter 000h CR 001h LF 002h TAB 003h None New Disable output delimiter Other Parameter or 0xFF CR LF ...

Page 25: ...rranty period to Giga Tms 8F No 31 Lane 169 Kang Ning Street Hsi Chih Dist New Taipei City Taiwan If this product is delivered by mail or by an equivalent shipping carrier the customer agrees to insure the product or assume the risk of loss or damage in transit to prepay shipping charges to the warranty service location and to use the original shipping container or equivalent Giga Tms will return ...

Page 26: ...IABLE FOR CONTINGENT INCIDENTAL OR CONSEQUENTIAL DAMAGES TO PERSONS OR PROPERTY GIGA TMS FURTHER LIMITS ITS LIABILITY OF ANY KIND WITH RESPECT TO THE PRODUCT INCLUDING ANY NEGLIGENCE ON ITS PART TO THE CONTRACT PRICE FOR THE GOODS GIGA TMS S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDIES ARE STATED IN THIS SECTION AND IN THE SECTION RELATING TO GIGA TMS S LIMITED WARRANTY ...

Page 27: ...8F NO 31 Lane 169 Kang Ning Street Hsi Chih Dist New Taipei City Taiwan TEL 886 2 26954214 FAX 886 2 26954213 WEBSITE www gigatms com tw EMAIL Sales Product Inquiries promag gigatms com tw Product Technical Support support gigatms com tw ...