Gifas FlashLED User Manual Download Page 16

Manual FlashLED Li-Ion 

– Maintenance and troubleshooting 

 

 

 

Page 16/17 

 

GIFAS-ELECTRIC GmbH · Dietrichstrasse 2 · CH-9424 Rheineck · Phone +41 71 886 44 44 · Fax +41 71 886 44 49 · [email protected] 

4. 

Maintenance and troubleshooting 

4.1 

Lithium-ion battery 

The following information and rules apply for Li-ion batteries to ensure proper and safe operation: 

 

Self-discharge:  

At room temperature, self-discharge is generally 5% per month. It does not occur linearly 
and depends on various parameters, such as temperature, charge level, battery status, etc. 
The battery therefore needs to be recharged every 12 months. 

 
Service life:  

If the battery is maintained well, up to 1000 charge cycles are possible. To achieve a long 
service life, recharge the battery after each use. Do not use damaged batteries 

– send in 

the light for repair. 

 
Charging conditions: If at all possible, charge the battery at room temperature and only use GIFAS chargers. The 

Li-ion battery does not have a memory effect: it can be charged at any time, regardless of 
the charging level, without damaging the cells. 

 
Storage:  

Protect the battery from temperatures above 45° C (e.g. continuous sun exposure), fire, 
water and moisture. Always store batteries at room temperature and in a dry place. 

 
Warranty: 

Batteries are parts that are subject to wear. If handled improperly, they can be damaged, 
thus significantly impairing their service life. For this reason, the battery is not provided with 
a warranty. 

 
 
 

4.2 

Inspection plan 

 
 
 
 
 
 

4.3 

Description of maintenance work 

The battery-powered lamp is maintenance-free and does not contain any parts that need to be serviced. 
 
 

4.4 

Troubleshooting 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Work to be carried out 

Period/interval 

Test the emergency light function 

According to country-specific regulations / when needed 

Fault/error message 

Possible cause 

Remedy 

New lamp does not function 

The lamp is delivered in power-
saving mode 

To start the lamp, place it in the 
active charging station for 5 
seconds and charge the battery 
completely 

No LED flashing in the charging 
status 

Deep battery discharge due to long 
disuse 

Charge for at least four hours, 
during which time the charging LED 
should light up again 

Lamp can no longer be charged 

In an older charger (only 230V 
input voltage), the miniature fuse is 
defective 

Contact the manufacturer (GIFAS), 
send in the charging station and (if 
needed) the lamp 

Lamp can no longer be charged, 
but charging station is OK 

Charging electronics or battery 
defective 

Contact the manufacturer (GIFAS), 
send in the lamp if needed 

An LED diode no longer lights up 

LED defective 

Send the lamp to GIFAS 

Emergency light ON/OFF setting 
does not work properly 

Faulty initialisation by magnetic 
switch on the charging station 

Send the lamp to GIFAS 

The operating time of the luminaire 
is only 10 minutes 

Battery is no longer functional 

Battery replacement by GIFAS 

Summary of Contents for FlashLED

Page 1: ...hLED Li Ion Imprint GIFAS ELECTRIC GmbH CH 9424 Rheineck Switzerland www gifas ch Technical changes and errors reserved This manual is property of GIFAS ELECTRIC GmbH and may not be reproduced copied translated transmitted duplicated or transferred to third parties in part or in whole without previous written authorization by GIFAS ELECTRIC GmbH version V2 06 0814 English ...

Page 2: ...lashLED Lamp and charging station 7 1 6 4 Radiation pattern 8 1 7 Responsibilities of the operator 9 1 8 Start up 9 1 9 Storage transport 9 1 10 Cleaning 10 1 11 Disposal of the device 10 2 Setting up the lamp 11 2 1 Notes on spare parts 11 3 Overview of functions 12 3 1 Explanations of the symbols 12 3 2 Indicator functions 12 3 3 Stylus functions 12 3 4 Operating modes 13 3 4 1 Basic functions 1...

Page 3: ...can be used for a variety of applications For example industrial trade fair and exhibition halls hangars depots operations rooms schools sports facilities and parks civil defence military facilities fire departments and municipal facilities police security and maintenance personnel shopping centres public buildings road and rail vehicles It is especially suitable for use as a work light such as du...

Page 4: ...electable lighting modes Memory function the last setting is retained Flash function Low light mode High protection type for lamp and charging station Robust housing made of polyamide Compact design Corrosion resistant charging contacts nickel and gold plated Vertically swivelling lamp head The FlashLED lamp head can become very hot during operation Therefore we recommend that you always take appr...

Page 5: ...Rheineck Phone 41 71 886 44 44 Fax 41 71 886 44 49 info gifas ch 1 5 Scope of delivery 1 5 1 FlashLED work and inspection lamp with emergency light function 1 5 2 FlashLED charging station 85 264 VAC 1 5 3 FlashLED vehicle connection cable with cigarette lighter plug for 12 24 VDC charging station ...

Page 6: ...h Emergency light 5 LED 3h Lighting current Original setting Max SPOT 200lm 650lm WIDE 200lm 350lm Full beam 400lm 1000lm Emergency light 500lm nicht verstellbar Light colour cool white 6100 7000K IP rating IP65 Protection class III Temperature range Operating 20 C to 45 C Charging 0 C to 45 C Dimensions Lamp 260 x 125 x 92 5mm H x B x T Lamp incl charging station 332 x 149 x 106mm Weight 1 12kg 1...

Page 7: ...ge 7 17 GIFAS ELECTRIC GmbH Dietrichstrasse 2 CH 9424 Rheineck Phone 41 71 886 44 44 Fax 41 71 886 44 49 info gifas ch 1 6 3 Dimensions FlashLED Lamp and charging station Die Ausführung BABS besitzt zusätzlich einen Ferritkern am 230VAC Stecker ...

Page 8: ... information Page 8 17 GIFAS ELECTRIC GmbH Dietrichstrasse 2 CH 9424 Rheineck Phone 41 71 886 44 44 Fax 41 71 886 44 49 info gifas ch 1 6 4 Radiation pattern Spotlight SPOT 3 x 10 Broad beam WIDE 2 x 38 Full Beam 3 x 10 and 2 x 38 ...

Page 9: ...ay only be performed by qualified personnel 11 Any procedure not expressly mentioned by the manufacturer in the instructions is not permitted 12 Installation of the charging station must be performed in accordance with the valid regulations 13 The packaging materials plastic polystyrene etc should not be stored within reach of children Although the FlashLED lamp has been designed for harsh environ...

Page 10: ...ce Battery powered lights batteries accessories and packaging should be disposed of in an environmentally friendly manner Do not dispose of battery powered lights and batteries in the household rubbish According to European Directive 2012 19 EU on waste electrical and electronic products battery lights that can no longer be used must be collected separately and sorted for environmentally friendly ...

Page 11: ...ing up the lamp 2 1 Notes on spare parts The Li ion battery and the motherboard can only be replaced together by GIFAS ELECTRIC In such a case send in the device for repair If the front protective glass is to be replaced a new seal must always be used No spare parts are available for the charging station The entire charging station must therefore be replaced ...

Page 12: ... und 2 x 38 Display for LED full light setting Flashing Brightness default setting has been changed Battery charge indicator Segments show the available battery capacity in 25 increments Red LED flashing light is in remaining light mode Icon Function Description Main On Off switch Switching light on and off each time the light is switched on the memory function is activated most recently selected ...

Page 13: ... in the event of a power outage at the charging station Once the supply voltage is detected the light checks the magnet s position If emergency light ON has been activated emergency lighting is provided after 5 seconds during a power failure When power has been restored the lamp turns off and is charged if required If the lamp is removed normally from the charger it does not switch on Operating mo...

Page 14: ...rged below 0 C and above 45 C 3 5 3 Deep discharge protection The Li ion battery comes with electronic deep discharge protection which ensures the battery is never fully discharged This protects it from irreparable damage Recharge the discharged battery after use whenever possible If the battery has undergone deep discharge due to a very long storage time without recharging the charging indicator ...

Page 15: ... light mode the lamp can only be switched on or off If the switched on lamp is placed in the active charging station it switches off If the switched on lamp is placed in the inactive charging station the light stays on the lamp functions the way it does when disconnected from the charging station 3 7 1 Emergency light ON In the event of a power failure the light switches to emergency lighting with...

Page 16: ...y can be damaged thus significantly impairing their service life For this reason the battery is not provided with a warranty 4 2 Inspection plan 4 3 Description of maintenance work The battery powered lamp is maintenance free and does not contain any parts that need to be serviced 4 4 Troubleshooting Work to be carried out Period interval Test the emergency light function According to country spec...

Page 17: ...Manual FlashLED Li Ion Declaration of conformity Page 17 17 GIFAS ELECTRIC GmbH Dietrichstrasse 2 CH 9424 Rheineck Phone 41 71 886 44 44 Fax 41 71 886 44 49 info gifas ch 5 Declaration of conformity ...

Reviews: