e) Check the voltage difference between of dummy 

speaker –23dB to -40dB. 

B.  CASING LEVEL

 

N O 

ITEM  

ALIGNMENT METHOD 

REMARK 

5. 

Audio TX Path CH8 

1. Check the radiated power correlate to golden sample. 
2. Plug the dummy speaker and dummy microphone into 

audio jet. 

3. Standard TX Deviation. 

a) Input mic level to dummy microphone and press 

‘PTT’ switch. 

b) Check max. Dev.  2.0KHz < max. Dev. < 2.5KHz. 
c) Check input level in 0.5~10mV to provide normal 

deviation 1.5KHz. 

4. Audio Frequency Response. 

a) Input a 2.0mv@1KHz audio frequency to dummy 

microphone and press ‘PTT’ switch. 

b) Check the response. 

i)    500Hz:  -5.0 dB to  –11.0 dB. 

2.5KHz: +3.0 dB to +9.0 dB  

5.Repeat CH1. 

Filter set: 
1.HPF 50Hz  
2.LPF 15K Hz 
3. PK + 

6. 

Function check and  
Intercom function 
(between sample and 
production unit) 

1. Turn on the radio power ,  the back-light should be on 

For a while and a good key chirp should be heard at  
the same time. 

2. The LCD display should be clear , not miss the segment 

when pressing ‘+’ and ‘-’ or ‘-’  key , the key tone 
should also be heard clearly. 

3. Set channel of the sample and production unit CH=11. 
4. Press ‘PTT’ switch  to intercom between sample and 

Production unit , the LED should be light. 

5. The sound quality between both should  be clear and no 

metal  sound .  

6. Press  ‘CALL’ key , the call tone should be heard clearly 

each other . 

7. Change channel of the production unit to CH=12 , then 

Press ‘PTT’ switch of sample. 

8. Any noise should not be heard from the speaker of   

Production unit. 

9. Press any key , the dead problem should not occur . 
10.Set CH1/code5,SG to be CH1/code4 and code6,check  
     the speaker mute. 
11.Set CH1/code37,SG to be CH1/code36 and code38,  
     check the speaker mute. 
12. Repeat item 10 and 11 for CH1. 

 

 

 
* Remark: 
 
TX mode : 
1.  Press and hold PTT button 
 
RX mode : 
1.  Release PTT button 

Power supply: Min DC 3.5v;Normal DC4.0v; Max DC4.5v 