Pump Specifications - P202-4120, P202-4121 and P202-4127

 

U.S.

 

Metric

Volume............................................................... 1.27 GPM* .........................4.8 L/min*

Discharge Pressure ...........................................

3190 PSI

 ............................220 Bar

Crankshaft Speed ..........................................................................................1450 RPM

Plunger Diameter............................................... 0.47” ...................................12mm

Plunger Stroke ...................................................

0.39”

 ...................................10mm

Crankshaft Diameter.......................................... 0.98” ...................................24mm

Key Width ..........................................................

0.31”

 ...................................8mm

Crankshaft Mounting .....................................................................................Either side

Crankshaft Rotation .........................................................Top of Pulley Towards Fluid End

Temperature of Pumped Fluids ......................... 140 

o

F .................................60 

o

C

Inlet Ports ......................................................................................................(2) 1/2”

 

BSP

Discharge Ports .............................................................................................(2) 1/4” BSP

Weight ...............................................................

13.9 lbs.

 .............................10 kg

Crankcase Oil Capacity ..................................... 9.5 Ounces. ........................0.28 Liters

* Theoretical displacement per revolution is approximately 0.115 ounce (3.39 cm

3

)

Important!   

The 1/8” rinsing connection on both sides serves to place a separating agent (e.g. 

DOP) behind the medium seal on the suction side.  This stops leakage (e.g. with Iscocyanate) 

from crystallizing.  When pumping different types of Freon, the pressure in the rinsing system 

should be approximately 7.25 PSI (0.5 bar) higher than on the suction side of the pumped me-

dium.

To vent the pump easily on the discharge side, it is recommeded to install a T-piece with a high-

pressure cut-off tap as close as possible to the discharge port.

HORSEPOWER RATINGS:

The rating shown are the power 

requirements for the pump.  Gas engine 

power outputs must be approximately 

twice the pump power requirements 

shown above.

We recommend a 1.15 service factor be 

specified when selecting an electric motor as 

the power source. To compute specific pump 

horse power requirements, use the following 

formula:

  

  HP = (GPM X PSI) / 1450

Horsepower Requirements 

P202-4120, P202-4121 and P202-4127 

RPM

GPM

500 PSI 1000 PSI 2000 PSI 3190 PSI

725

0.64

0.22

0.44

0.88

1.4

900

0.79

0.27

0.55

1.09

1.7

1200

1.05

0.36

0.72

1.5

2.3

1450

1.27

0.44

0.88

1.8

2.8