U.S. .............................. Metric

Volume ................................................................. 23.5 GPM ..................... 88.9 LPM
Discharge Pressure .............................................. 3045 PSI ....................... 210 BAR
Speed .......................................................................................................... 800 RPM
Inlet Pressure ....................................................... -4.35 to 145 PSI

....................

-0.3 to 10 BAR

Plunger Diameter ................................................. 1.26” ............................. 32mm
Plunger Stroke ..................................................... 1.89” ............................. 48mm
Crankshaft Diameter ............................................ 1.65” ............................. 42mm
Key Width ............................................................ 0.47” ............................. 12mm
Crankshaft Mounting .................................................................................. Either side
Shaft Rotation ...................................................... Top of pulley towards manifold
Temperature of Pumped Fluids ........................... Up to 140 

o

F ................. 60 

o

C

Inlet Ports ................................................................................................... (2) 1-1/4" BSP
Discharge Ports ........................................................................................... (2) 2-1/2" BSP
Weight .................................................................. 309 lbs. ......................... 140 kg
Crankcase Oil Capacity ....................................... 1.1 Gal. ......................... 4.2 Liters
Fluid End Material ..................................................................................... Bronze

Specifications

Model GP6132

Consult the factory for special requirements that must be met if the pump is to
operate beyond one or more of the limits specified above.

HORSEPOWER RATINGS:
The rating shown are the power requirements for the pump.  Gas engine power outputs must be approxi-

mately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source.  To

compute specific pump horsepower requirements, use the following formula:

HP = (GPM X PSI) / 1450

RPM

GPM

1000 PSI

1500 PSI

2500 PSI

3045 PSI

400

11.8

8.1

12.2

20.3

24.7

500

14.7

10.1

15.2

25.3

30.8

600

17.6

12.2

18.2

30.4

37.0

700

20.6

14.2

21.3

35.5

43.2

800

23.5

16.2

24.3

40.5

49.4

GP6132 HORSEPOWER REQUIREM ENT S

Summary of Contents for GP6132

Page 1: ...age 4 Parts List Kits page 5 Torque Specifications page 5 Repair Instructions page 6 Troubleshooting Chart page 7 Recommended Spare Parts page 7 Dimensions back page Warranty Information back page Upd...

Page 2: ...y the arrows on the pump crankcase Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries Inc Required horsepower for system operation can b...

Page 3: ...GP6132 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above HORSEPOWER RATINGS The rating shown are the power requir...

Page 4: ...4 EXPLODED VIEW GP6132...

Page 5: ...eal for 12 2 14 12549 Bearing Cover 2 15 13205 Radial Shaft Seal 2 16 08055 O Ring for 14 2 20 13206 Taper Roller Bearing 2 20A 13207 Fitting Disc 1 5 21 13208 Shaft Protector 1 22 06895 Crankshaft 1...

Page 6: ...ge becomes too heavy and causes output and operating pressure to drop 15 When reassembling tighten plunger screw 36 to 33 ft lbs 45 NM Mounting Valve Casing 16 Check o rings on seal case 41 17 Clean s...

Page 7: ...toppage air leaks correctly sized inlet plumbing to pump Accumulator pressure Recharge Replace accumulator Unloader Check for proper operation Cavitation Check inlet lines for restrictions and or prop...

Page 8: ...ear and tear to standard wear parts 3 Use of repair parts other than those manufactured or authorized by Giant 4 Improper use of the product as a component part 5 Changes or modifications made by the...