background image

+1

3

ALL  CLEAR    UNIT SELECTION                      CIRCUMFERENCE SETTING                                    

CLOCK  SETTING

ODO  SETTING

RESET  OPERATION (DST=0, RTM=0, AVG=0, MAX=0)

4

1

2s

MAIN UNIT SETUP (Fig.1) 

PROGRAM THE COMPUTER (ALL CLEAR)

1. A battery is already loaded in the main unit when purchased.

2. Hold down the SET button 

 and RESET button 

 simultaneously for more than 3 

seconds to program the computer and clear all data. 

IMPORTANT: Be sure to 

program the computer before it is be used, otherwise the computer may run 

errors.

3. The LCD segments will be tested automatically after the unit is programmed.

4. Press MODE button 

 to stop LCD test, then the flickering "KM/H".

UNIT SELECTION

Press MODE button 

 to choose KM/H or M/H. Then press the SET button 

 to 

store selection.

WHEEL CIRCUMFERENCE

1. Roll the wheel until the valve stem at its lowest point close to the ground, then 

mark this first point on the ground. 

(Fig. a)

2. Get on the bike and have a helper push you until the valve stem returns to its 

lowest point. Mark  the second point on the ground. (Sitting on the bike achieves a 

more accurate reading since the weight of the rider slightly changes the wheel 

circumference).

3. Measure the distance between the marks in millimeters. Enter this value to set the 

wheel circumference. 

Option: Get a suitable circumference value from the 

table.

 

(Fig. b)

4. Adjust the wheel circumference as the data setting process.

5. Unit will change to the normal operation after this circumference setting.

FUNCTIONS (Fig.3)

Current Speed

 

0.0–199.9Km/h (120.0 Mile/h), 0.1Km/h (Mile/h), +/- 1%

The current speed is always displayed on the upper set when riding. It displays 

current speed up to 199.9 Km/h or 120.0 Mile/h (for wheel diameters over 24 inches).

CLK: 

12HR or 24HR Clock 

1H00M–12H59M or 0H00M–23H59M, 1 Minute, +/- 0.3%

It can display the current time either in 12HR or 24HR clock.

DST:

 Trip Distance 

0.00–999.99Km (Miles), 0.01Km (Mile), +/- 0.01%

The DST function accumulates the distance data from the last RESET operation as 

long as the bike is being ridden.

PRECAUTIONS 

1. This computer can be used in the rain but should not be used under water. 

2. Don’t leave the main unit exposed to direct sunlight when not riding the bike. 

3. Don’t disassemble the main unit or it’s accessories.  

4. Check relative position and gap of sensor and magnet periodically. 

5. Clean the contacts of the bracket and the bottom of the main unit periodically. 

6. Don’t use thinner, alcohol or benzine to clean the main unit or its accessories when 

they become dirty.

7. Remember to pay attention to the road while riding.

RTM: 

Riding Time 

0M00S-59M59S, 1 Second, 0H00M-99H59M, 1 Minute, +/- 0.03%

1. The RTM totals the riding time from the last RESET operation.

2. It displays in 1 second increments when RTM is less than 1 hour and changes to 1 

Minute increments after 1 hour. It will restart from zero after 100 hours.

AVG: 

Average Speed                     0.0–199.9Km/h (120.0Mile/h), 0.1Km/h (Mile/h), +/- 0.1%

1. It is calculated from the DST divided by the RTM. The average data counted is 

from the last RESET to current point. 

2. It will display "0.0" when RTM is less than 4 seconds.

3. It is updated about one second when RTM is over 4 seconds.

MAX:

 Maximum Speed 

(Axact 11 only) 

0.0–199.9Km/h (120.0Mile/h), 0.1Km/h (Mile/h), +/- 1%

It shows the highest speed from the last RESET operation.

TMP: 

Current Temperature °C / °F                                            -10°C ~ 60°C (14°F ~ 140°F)

ODO: 

Odometer                                                        0-99999Km (Miles), 1Km (Miles), ± 0.1%

The ODO accumulates total distance as long as the bicycle is running, the ODO data 

can be cleared by the All Clear operation only.

: SCAN

1. Auto-Scanning Display Mode.

Press the MODE button 

 till the       symbol is displayed. The computer will change 

the display modes in a loop sequence automatically every 5 seconds.

2. Fixed Display Mode.

Press the MODE button 

 to turn off the       symbol and select a desired display 

mode; the computer will stop the auto-scanning display operation.

 /    : Speed Pacer 

(Axact 11 only)

It flashes the      speed pacer arrow while the current speed is higher than the 

average speed and the down arrow      flickers conversely.

BUTTON AND OPERATIONS

MODE BUTTON 

 

Quickly press this button to move in a loop sequence from one function screen to another. 

LOCK/SET BUTTON 

Press this button 2 seconds to get in or out the setting screens when you want to 

reset to bike, or the current time of the CLK.

LIGHT/RESET BUTTON 

(Fig. 6)

1. Light for 4 seconds after each press.

2. The symbol "     " will apper to indicate the EL back-light functuon is at working status.

CLOCK SETTING (Fig.2)

1. Change the LCD display to CLK screen.

2. Press the SET button 

 to enter the clock adjusting screen to setting the clock.

3. A quick press of the MODE button 

 to select 12HR or 24HR.

4. Adjust the clock data as the data setting procedures.

RESET OPERATION (Fig.4)

1. Hold down the RESET button 

 till the LCD screen is blank, then release it. The 

computer will reset AVG, DST, RTM and MAX data from stored values to zero.

2. It cannot reset ODO, CLK.

AUTOMATIC START/STOP

The computer will automatically begin counting data upon riding and stop counting 

data when riding is stopped. The flickering symbol "     " indicates that the computer 

is at start status. To preserve battery, this computer will automatically switch off and 

just displays the CLK data when it has not been used for about 15 minutes. The 

power will be turned on by pressing the SET button 

.

KEY-LOCK (Fig. 5)

To protect you computer, you may can press the lock button to lock the MODE button 

 

Whenever you press the lock button, the functions of the MODE button 

 will be disabled. 

You may can unlock the MODE button 

 by pressing the lock button 

 again. 

AUTO SLEEP MODE 

To preserve battery, this computer will automatically switch to sleep mode and just 

displays the CLK data when it has not been used for about 15 minutes. The power 

will be turned on automatically by riding the bike or by pressing the button.

LOW BATTERY INDICATOR 

1. The symbol "       " will appear to indicate the battery is nearly exhausted. 

2. Replace battery with a new one within a few days after the symbol was appeared, 

otherwise the stored data may be lost when the battery voltage is too low.

BATTERY CHANGE (Fig. c)  

1. All data will be cleared when battery is replaced. 

2. This computer allows you to re-key in data of ODO which you have had rode 

after replacing battery. 

3. Keep record the ODO data before you remove the old battery. 

4. Replace with a new CR2032 battery in the compartment on the back 

of the computer with the positive (+) pole toward the battery cap. 

5. Program the main unit again.

English

 

Sensor: 

No Contact Magnetic Sensor. 

 

Battery Type: 

3.0V Battery X 1 (Typical No. CR2032)     

 

Battery Operating Life: 

CR2032 in Main Unit  About one year 

 

  (based on the average riding time of 1.5 hours per day)

 

Dimensions/Weight: 

34x 52 x 15mm / 21g

 Wheel Circumference Setting: 

1mm - 3999mm (1mm increment)

  Operation Temperature: 

0°C ~ 50°C (32°F ~ 122°F)

 

Storage Temperature: 

-10°C ~ 60°C (14°F ~ 140°F)

2s

TROUBLE SHOOTING   

Check the following before taking unit in for repairs.  

PROBLEM                   CHECK ITEM                                   REMEDY 

1. Is the battery dead?

2. Is there incorrect battery installation?

1. Is it at the recalibrating or clock setting 

    screen?

2. Are the contacts between the main 

unit and the bracket poor?

3. Are the relative positions and gap of 

sensor and magnet correct?

4. Is the wire broken?

5. Is the circumference correct?

Did you leave main unit under direct sunlight 

when not riding the bike for a long time?

Is the temperature below 0°C (32°F)? 

No 

display

No 

current 

Speed or

incorrect 

data

Irregular 

display
LCD is 

black

Display

is slow

1. Replace the battery.

2. Be sure that the positive pole of the 

    battery is facing the battery cap.
1. Refer to the adjusting procedure and 

    complete the adjustment.

2. Wipe contacts clean.

3. Refer to Installarions and readjust 

data correctly.

4. Repair or replace wire.

5. Refer to "CALIBRATION" and enter 

    correct value.

Refer to the "MAIN UNIT SETUP" 

and initiate the computer again.
Place main unit in the shade to return 

to normal state.No adverse effect on 

data.
Unit will return to normal state when 

the temperature rises.

3s

+


 CYCLE COMPUTER

MODE

LOCK/

SET

LIGHT/

RESET

BATTERY CHANGE

Tire Size

Circumference 

Nunber

18 Inch 

1436 mm

20 Inch 

1596

22 Inch 

1759

24x1.75 

1888

24 Inch 

1916

24x 1  3/8 

1942

26x1.40 

1995

26x1.50 

2030

26x1.75 

2045

26x1.95 

2099

26x2.1 

2133

700C TUBULAR 

2117

700x20C 

2092

700x23C 

2112

700x25C 

2124

700x28C 

2136

700x32C 

2155

700x35C 

2164

700x38C 

2174

27.5 Inch 

2193

28 Inch (700B) 

2234

28.6 Inch 

2281

b.

POPULAR TIRES 

CIRCUMFERENCE 

REFERENCE TABLE

15m

WHEEL CIRCUMFERENCE

a.

2nd                         1st

SEGMENTS

LCD

AUTO TEST

+1

+1

+1

CLOCK             DST               RTM              AVG               MAX               TMP               ODO              SCAN

OK!

0

~

23

0

~

5

0~3

0~9

0~9

0~9

END SETTING

0~9

2s

6.

 Key-lock

EL Back-light

Data Setting Mode

c.

0~3

2s

OK!

2s

MODE

Low battery indicator

5.

Auto Sleep and

 Key-lock on

ON

OFF

Key-lock off

DST 

RTM 

AVG 

MAX

2

WIRED

/

(AXACT 11 only)

(AXACT 11 only)

Gasket

Battery 

CR2032

Battery

cap

3V

CR2032

+

3V

CR2032

+

Screwdriver

Screw

CR2032

Reviews: