10
Installation of venting
Install the correct venting for your model according to the venting
manufacturer’s instruction and the guidelines below (
see Table 7
and Table 8
). Refer to the manufacturer’s technical literature for
specific part numbers and instructions.
Venting Guidelines
DO NOT
• Do not use cellular core PVC/CPVC, Radel, or galvanized materi-
al to vent this appliance.
• Do not combine vent components from different manufacturers.
• Vent diameter must not be reduced.
• Do not connect the venting system with an existing vent or
chimney.
• Do not common vent with the vent pipe of any other manufac-
turer’s water heater or appliance. Giant water heaters can only
be common vented using a Giant certified common vent sys-
tem. Common venting is approved for Canadian and U.S. instal-
lations.
MUST DO
• This water heater is a direct vent water heater and therefore is
certified and listed with the vent system. You must use vent
components that are certified and listed with the water heater
model.
• The vent system must vent directly to the outside of the building
and use outside air for combustion.
• Avoid dips or sags in horizontal vent runs by installing supports
per the vent manufacturer’s instructions.
• Support horizontal vent runs every four (4) feet (1.2 m) and all
vertical vents run every six (6) feet (1.8 m) or in accordance with
local codes.
• Venting should be as direct as possible with a minimum number
of pipe fittings.
• Vent connections must be firmly pressed together so that the
gaskets form an air tight seal.
• The vent piece connected to the water heater must be secured
with one self-tapping screw.
INFORMATION
• Refer to the instructions of the vent system manufacturer for
component assembly instructions.
• If the vent system is to be enclosed, it is suggested that the de-
sign of the enclosure shall permit inspection of the vent system.
The design of such enclosure shall be deemed acceptable by the
installer or the local inspector.
If it becomes necessary to access an enclosed vent system for
service or repairs, Giant is not responsible for any costs or
difficulties in accessing such vent system. The warranty does
not cover obtaining access to a vent system in an enclosed
environment.
Table 7
Manufacturer
Listed and Tested Vent Products
Telephone
Fax
Contact
Ubbink
Rolux Condensing Vent System
800-363-9354
514-640-0969
www.giantinc.com
Concentric to Twin pipe adapter
IPEX
Concentric/low profile termination kit
866-473-9462
514-769-1672
www.ipexinc.com
Centrotherm
InnoFlue Vent System
(single wall SW, 3-inch (7.6 cm) diameter)
877-434-3432
518-618-3166
[email protected]
www.centrotherm.us.com
Heat-Fab
Saf-T Vent SC System
800-772-0739
413-863-4803
www.heatfab.com
Metal-Fab
Corr/Guard Vent/Air Intake System
800-835-2830
316-943-2717
www.metal-fabinc.com
Table 8
Manufacturer
Product
Vertical Termination
Horizontal Termination
Ubbink
Rolux
96000050-A
96000051-A, 96000052-A
PVC/CPVC concentric to twin pipe adapter
IPEX
Concentric/low profile termination kit
Centrotherm
InnoFlue
ICRT3539
ISELL0387UV
Heat-Fab
Saf-T Vent
Saf-T Vent CI Plus
Wall Termination
Saf-T Vent CI Plus Rain Cap
Metal-Fab
Corr/Guard
3CGRVDK
3CGRVT
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
N O T I C E