ML-650 Electric Lock (with Mechanical Override)

Installation Instructions

Specifications

Dimensions

Wiring Diagram

Lock Mode: Fail-Secure

Operating Voltage: 12~24VAC/DC

Current Draw: 500mA / 12VDC, 250mA / 24VDC

Operating Temperature: -10°C~+49°C

Humidity: 0~85% non-condensing

Preload: 300 lbs of pressure strength

Latch Throw: 13mm

Solenoid Testing: Tested up to 250,000 cycles

Relock Delay Time: 3 seconds

Optional Cylinder: EYC-72

Unti:mm

ML-650M

 

28

100

150

12

5

2

Lock Body

Circuit Description

Strike Plates

Currrent Draw

Pull in (2 secs)

Holding

Energy-saving

Door closed (3 secs)

De-energized

Time (seconds)

De-engergized

A. De-energized: Door is in locked status.(Operating in fail-secure mode)

B. Pull-in:The electric lock is energized through access control devices. 

    (Please refer to the wiring diagram)

C. Energy-saving: After supplying power to unlock for 2 seconds , the current 

    draw will drop to save energy. During this time, the electric lock remains unlocked.

D. Door closed:

     After door is closed, the NIB (deadlatch) will will retract into the lock housing 

     and press the internal micro switch. After door keeps closing for 3 seconds, the lock 

     will be completely de-energized and the door will remain locked.

(Without keeping door closed for 3 seconds, the electric lock will not be de-energized 

and remains unlocked.)

30 Backset

White

White

N.C.

COM
N.O.

Access Control
(N.O. + COM.)

Power

Supply

Black
Red

Yellow
Green
Blue

Door Status Output

Trigger to unlock

12~24VDC/AC