3-1

ML-300-SW

Operating Voltage» 12~24VDC/AC
Voltage Tolerance» ±10%
Current Draw» 250mA/12VDC; 150mA/24VDC
Version Changeable» Fail-safe or Fail-secure  
Operating Temperature» 14°F to 120°F (-10°C~+49°C)
Humidity» 0~85% non-condensing
Lock bolt sensor switch output (For ML-300-SW): 
SPDT rated 3A/125VAC 
Solenoid testing» Tested to 1,000,000

!

cycles

Net Weight» 815g
Just applicable to vertical installation

Electric Lock
Installation Instruction

Specification

Double Swing Doors

Double swing door

Outswing

Inswing

Version Changeable:

Take out the Screw 1 , release screw 2 , move the 

position and then tighten both screws.

“Fail-Safe” 

(Power to Lock)

“Fail-Secure” 

(Power to Open)

Caution:

Fixing Lug

NIB

Lock bolt

Strike Plate

For double swing door For single swing door

Euro profile 

key cylinder

Stud bolt Position

Packing Contents

Do not completely remove screw 2 (as marked in the figure) 

as the interior solenoid might fall off.

For fail-safe mode

For fail-secure mode