Dip Switch

Mounting Screws

(2 pcs.)

Connector

Potentiometer

(Sensitivity Volume)

Radar

Cover

Indicator LED

 

  

 

Mounting

Template

Installation
Instruction

cable

Mounting Screws

(2 pcs.)

Mounting height of 
4.0m (13.15ft) or lower

4.0m
(13.15ft)

Ensure there are no moving 
objects in the detection areas

Ensure no condensation gets 
onto the sensor

Avoid heavy rain and snow

If possible ensure no 
accumulation of snow or water 
on the floor

The Radar part of the MCS-3H-
KB02 sensor may be negatively
influenced by metal close to or
in the detection area

Center area

Right area

Microwave Sensor MCS-3H-KB02

1. Overview

5. Installation Instructions 

2. Dimensions

3. Specifications

Operation Manual

Standby
Initializing
Detecting
Change of DIP Switch

75mm(2.95”)=Standard Mounting Pitch

155mm (6.10”)

40mm (1.56”)

35mm (1.37”)

43mm (1.69”)

60mm (2.36”)

 

 

! "

#  $%
#  

 # 
   
&


(

Specifications may change without notice.

4.0

m

(13.15

ft

Max

12~24 VAC/DC

2W (VA)

Doppler method: (moving body detection)

24.20 

GHz

0.5 

seconds

App.

Form C Relay DC50

V

0.1

A

Resistor Load

-20

~+60

 (-4

~140

)

Below 80%

Depth Detection: +15~51 (MAX 54)
Adjust the left and right: Left 15 (MAX 30) Right: 15 (MAX 30)

0.24 

lb.

(0.11

Kg

)

4. Mounting Precautions

'((

)#(

Drilling may cause electric shock. Be careful of hidden 
wires inside the automatic door operator cover.

Attach the template at the 
mounting position.

1

Drill mounting (3.5mmø)

and wiring (10mmø) holes.

2

Remove the sensor cover as
illustrated

Lift the sensor cover.

Flat screw

Slit in base

driver

3

Attach the sensor with the screws.

4

Door Controller Wiring

Red
Black
White
Yellow
Green

AC/DC
12 to 24

V

±10%

COM
N.O.
N.C.

Power

(Non Pole)

5

House connectors in the
space provided.

6

Replace cover.

7

Removing the cover after

installation

Flat

screwdriver

Push

Pull

Push

Pull

1

7

2

1

2

6. Adjusting Sensitivity

Turn the potentiometer clockwise to increase the sensor sensitivity.
Turn the potentiometer counterclockwise to decrease the sensor sensitivity when
there is nothing in the detection area.

Sensitivity Volume

H

L

7. Adjusting Detection Area Width and Depth

Detection Area Adjustment

 Detection area varies depending on walking speed

 Adjustment as illustrated below

Left

Right

Far

Near

Radar

Please do not touch
the surface

Installation height “2.2m”and Sensitivity set to “High”.

m

2.0

1.0

0

1.0

2.0

1.0

2.0

3.0

4.0

27 degree

setting

42 degree

setting