Dip Switch
Mounting Screws
(2 pcs.)
Connector
Potentiometer
(Sensitivity Volume)
Radar
Cover
Indicator LED
Mounting
Template
Installation
Instruction
cable
Mounting Screws
(2 pcs.)
Mounting height of
4.0m (13.15ft) or lower
4.0m
(13.15ft)
Ensure there are no moving
objects in the detection areas
Ensure no condensation gets
onto the sensor
Avoid heavy rain and snow
If possible ensure no
accumulation of snow or water
on the floor
The Radar part of the MCS-3H-
KB02 sensor may be negatively
influenced by metal close to or
in the detection area
Center area
Right area
Microwave Sensor MCS-3H-KB02
1. Overview
5. Installation Instructions
2. Dimensions
3. Specifications
Operation Manual
Standby
Initializing
Detecting
Change of DIP Switch
75mm(2.95”)=Standard Mounting Pitch
155mm (6.10”)
40mm (1.56”)
35mm (1.37”)
43mm (1.69”)
60mm (2.36”)
! "
# $%
#
#
&
'
(
Specifications may change without notice.
4.0
〔
m
〕
(13.15
〔
ft
〕
Max
12~24 VAC/DC
<
2W (VA)
Doppler method: (moving body detection)
24.20
〔
GHz
〕
0.5
〔
seconds
〕
App.
Form C Relay DC50
〔
V
〕
0.1
〔
A
〕
Resistor Load
-20
℃
~+60
℃
(-4
℉
~140
℉
)
Below 80%
Depth Detection: +15~51 (MAX 54)
Adjust the left and right: Left 15 (MAX 30) Right: 15 (MAX 30)
0.24
〔
lb.
〕
(0.11
〔
Kg
〕
)
4. Mounting Precautions
'((
)#(
Drilling may cause electric shock. Be careful of hidden
wires inside the automatic door operator cover.
Attach the template at the
mounting position.
1
Drill mounting (3.5mmø)
and wiring (10mmø) holes.
2
Remove the sensor cover as
illustrated
Lift the sensor cover.
Flat screw
Slit in base
driver
3
Attach the sensor with the screws.
4
Door Controller Wiring
Red
Black
White
Yellow
Green
AC/DC
12 to 24
〔
V
〕
±10%
COM
N.O.
N.C.
Power
(Non Pole)
5
House connectors in the
space provided.
6
Replace cover.
7
※
Removing the cover after
installation
Flat
screwdriver
Push
Pull
Push
Pull
1
7
2
1
2
6. Adjusting Sensitivity
Turn the potentiometer clockwise to increase the sensor sensitivity.
Turn the potentiometer counterclockwise to decrease the sensor sensitivity when
there is nothing in the detection area.
Sensitivity Volume
H
L
7. Adjusting Detection Area Width and Depth
Detection Area Adjustment
※
Detection area varies depending on walking speed
※
Adjustment as illustrated below
Left
Right
Far
Near
Radar
Please do not touch
the surface
Installation height “2.2m”and Sensitivity set to “High”.
〔
m
〕
2.0
1.0
0
1.0
2.0
1.0
2.0
3.0
4.0
〔
27 degree
〕
setting
〔
42 degree
〕
setting
〔
54 degree
〕
setting
Left area
Copyright © All Rights Reserved. P-MU-MCS-3H-KB02 Published: 2019.10.16