Installation Steps

Copyright © 2016 All Rights Reserved.   P-MU-GK460 Published: 2017.03.31

Please ensure that there is no back pressure on the keeper from the latch. As with most strikes this may cause the strike 
to bind and malfunction. It could also cause undo pressure on the solenoid and eventual failure of the strike.

Note

Place the wire inside the connector and use 

pliers to press down on the head of the 

connector evenly.

Installing the Crimp Connectors

Connect to the power and test the 
electric strike before finally mounting 
the unit

Mark the position of the latch bolt on 
the door jamb as shown in figure

Align the installation template
to the marked line

Measure the vertical and horizontal position
of the latch bolt on the door leaf

Installation on Wood and Hollow Metal Frame:

Drill and cut the frame according to
the template

6

5

Install the mounting tabs

4 7/8" (123.8mm)

3 3/8" (85mm)

3/16" (5mm)

Fail-Safe when 
"1" facing up

Fail-Secure
when " 2" 
facing up

*Factory default setting is Fail-Secure.

2. Reverse the round screw.

3. Put back the round 
    screw and plug.

Fail-Safe / Fail-Secure Reversible

1 1/4” (31.75mm)

3 3/8”(85mm)

(5mm)

3/16”

4 7/8” (123.8mm)

1 1/4" (31.75mm)

(5mm)

3/16”

1. Remove the plug and
    take out the round
    screw.