Copyright All Rights Reserved.
Page 3 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Ⅳ
Operation Instruction:
*xxxxxx#
Enter Program Mode
,
Enter 6-digital Codes
,
(Default 123456)
* #
Exit Program Mode
01*xxxxxx xxxxxx #
Change Default Password, Press twice new 6-digital Codes
02*xxxx #
Controller Station Setting
[
001-254
]
05*xxx#
Access only with the password, 0000-Unavaliable (Default, 0000)
Adding or Revised the Cards No.
10*xxxx*XXXXXXXXXX #
Slot Position =00001~01000 and enter the 10 digital Cards No.
Adding the batch series Cards No.. XXXX=the beginning position
*XXXXX=the quantities of the batch series card No.
12*XXXX*XXXXX#
(The access mode is for Card Only) (ps. x
≦
01000)
Modify the cards access parameter
xxxxx= The beginning slot position
XXXXX= the ending slot position From=00001~01000
N is 0= Access not allow
,
1=Card only
,
2=Cards or Code
,
3=Card & Code
,
4= Clear card information
13*xxxxx*XXXXX*N #
(When modify the Mode to “Card or Code” or “ Card & Code”
,
the
default Code is 0000.
14*xxxxx*XXXX#
Set the position of the Code; xxxxx=slot position XXXX=4-digital
Code (Position =00001~01000)
15*99#
Clear all Cards (Not including Master Cards)
17*xxxxxxxxxx#
When forget the Cards slot position
,
can clear the cards information
by enter Cards No..
21*xxx#
Alarm Time Delay Setting xxx=000~255 Second
s
Dual relays programmable time delay xxx=000~250 Second
s
(External Relay for Security System)
22*xxx#
(000 Latched Operation) (Default is 15 Second
s
)
Master Cards Setting x=(1 or 2). 2 Master Card available
25*X#
In the normal status, proximity the Master cards to Program Mode.
26*xxxxx*XXXXX#
Security Cards arrange Setting XXXXX=00001~01000 .The arrange
of the No. should be continuing which can’t skip the No.
x=0 General Setting Mode (Default x=0)
30*x#
x=1 Card Only. Access the door by reading cards that no matter the
cards are set into the system or not.
32*x#
Anti Pass Back Function
x=0/ OFF X=1/ ON
33*x#
Two Doors Synchronize
x=0 OFF X=1 ON
,
Access