IV. Wiring Diagram 

Door Status

 

For DC use only

For AC/DC

 

 

Note

 

1. 

It is suggested to use a linear power supply unit to prevent reading range 
reduction at the card reader. 

2. 

It is suggested to use #22~26 AWG insulation wire. 

3. 

Exit button is at N.O. contact. 

4. 

With CE qualification EMC specification. 

5. 

The door strike or relay must have a varistor or a diode across the door strike 
terminals to suppress the back EMF of the strike – failure to do so will 
damage the relay contacts and electronic components, or even burn the 
controller. 

Summary of Contents for DG-800

Page 1: ...ockout Function The controller will lockout for 60 seconds after entering 5 times invalid codes or cards The keypad doesn t beep during the period of time 5 Controller with keypad sound avoids incorre...

Page 2: ...ise free environment Keypad Backlight 12 digits 0 9 Input 2 contacts for Request To Exit button 1 contact for door reed switch Output 2 relays N O N C Com Dry Contact LED indicator 2 LED indicators di...

Page 3: ...tay On The slot position of second relay is available The slot position of second relay is unavailable Beep Standby 1 Beep Valid card key press enter programming mode 3 Beeps Invalid card incorrect PI...

Page 4: ...to prevent reading range reduction at the card reader 2 It is suggested to use 22 26 AWG insulation wire 3 Exit button is at N O contact 4 With CE qualification EMC specification 5 The door strike or...

Page 5: ...ws the keypad to be programmed to grant access with either Proximity Card only PIN or Proximity Card Proximity card and PIN 1 Enter programming mode 2 Press 0 Right Yellow LED rapid flash 3 Press 00 1...

Page 6: ...ode 7 Adding a Proximity Card and PIN to Relay 1 a 1 Enter programming mode to select slot position 000 999 Left Green LED stay on Right Yellow LED rapid flash to indicate the slot position is availab...

Page 7: ...eps of 8 a to add new card 9 Changing Master Code 1 Enter programming mode 2 Press 3 Right Yellow LED rapid flash 3 Enter 5 digit master code twice e g 45678 45678 1 beep Right Yellow LED stay on 4 Pr...

Page 8: ...on is unavailable 3 Press 1 beep Left Green LED stay on Right Yellow LED rapid flash 4 Repeat the steps of 11 a to add new card 12 Turning Anti Tamper Alarm Function ON OFF 1 Enter programming mode 2...

Reviews: