Copyright © Gianni industries, inc. All Rights Reserved.
P-MU-DG-200 Ver. A Publish: 2009.11.30 Page: - 3 -/ 5
V. Operation Instruction:
The master code comprises of a five-digit number and is used to access
programming functions of the digital keypad and cannot be used for access i.e. It
cannot be the same as other PINs. The default master code is set to 12345. Under
normal operation the keypad is used for entering PIN to gain access. In the
programming mode, the keypad can be used to add/delete PINs, set relay strike time
and other operation functions.
1. Enter programming mode
:
Enter the master code twice 12345 12345 to enter programming mode (1 beep,
rapid yellow LED flash). (If no data is entered within 50 seconds, the system will exit
programming mode; or press # to exit the programming mode).
2. Setting the Relay Strike Time
The relay strike time determines the amount of time that the door remains unlocked
after a valid PIN is entered.
NOTE: Enter 00 will set the relay strike time to 0 second (relay set to toggle
mode)
1.
Enter programming mode
2. Press
*
300 for Relay 1 (rapid green LED flash) → Enter 00~99 (1 beep, green
LED stay on)
Press
*
400 for Relay 2
(rapid red LED flash) → Enter 00~99 (1 beep, red LED
stay on)
3. Press # (1 beep) back to programming mode
4. Press # again (1 beep) back to standby mode (slow yellow LED flash)
3. Clear Memory of All PINs of Relay 1
1. Enter programming mode
2. Press
*
888 (green LED stay on)
3. Press 00 (rapid green LED flash, 5 beeps)
4. Press # (1 beep) back to programming mode
5. Press # again (1 beep) back to standby mode (slow yellow LED flash)
4. Clear Memory of All PINs of Relay 2
1. Enter programming mode
2. Press
*
999 (red LED stay on)
3. Press 00 (rapid red LED flash, 5 beeps)
4. Press # (1 beep) back to programming mode.
5. Press # again (1 beep) back to standby mode (slow yellow LED flash)