5. Using time of battery

1. Current and voltage:
    The battery is used to supply the DC input voltage required by the product, and 
its rated voltage must be in line with the rated input voltage of the inverter, beyond 
the  input  voltage  range  of  the  inverter,  and  the  cross  connection  will  cause  the 
product to be under voltage or under voltage protection.
At  the  same  time,  the  battery  must  provide  enough  current  for  inverter,  a  small 
capacity battery is not able to drive high power appliances, in this case, usually due 
to  excessive  current  and  battery  discharge  the  battery  terminal  voltage  low, 
undervoltage protection products appear
    The simple formula for the battery current is the load power / the battery voltage. 
As the inverter itself will be part of the loss, so the actual current will be greater than 
this value of about 10%. For example: the battery voltage is 12VDC, the load power 
is 400W, then the actual current size of the battery is about 400W÷12Vx110%=37A
  
2. Battery working time
    The using time of battery depends on battery capacity (AH) and the power of the
connected load (W), the calculating method is: Time (hours) =battery capacity (AH) 
× battery output voltage (V) x efficiency rate ÷ electrical power of using (W) such as 
the 12V DC input inverter uses the 12V battery, if the battery capacity is 200AH and 
at this time the inverter is driving 400W power load, the efficiency rate is 90% when 
the  battery  is  full,  according  to  the  formula  above,  the  battery  use  time 
=200(AH)÷(400÷12x110%) = 5.4 (Hour). This means the battery can be used for 5.4 
hours.

Notice: 

The  nominal  battery  capacity  is  the  discharge  capacity  in  20  hours 

discharge rate ,under the condition when the discharge current exceeds this value, 
the discharge capacity will be reduced, the corresponding discharge time will be 
shortened  than  the  calculation  value,  this  part  of  the  specification  can  refer  to 
battery  manufacturer,and  whether  the  battery  fully  charged  will  also  affect  the 
results.

6. CONNECTION

1). Grounding
    The power inverter has a terminal on the back panel marked "Grounding" or "      ". 
This is used to connect the chassis of the power inverter to the ground.

5

4. Assembe

1. The position of Mounting
    First ensure that there is enough space to install the inverter, while the installation 
location must meet the following requirements:
(1) Drying: Do not use water or other liquids dripping on the inverter
(2)Cool: a working environment temperature of the product is 0-40

, preferably a 

temperature of 10-25

, at a temperature as low as possible within this range

(3)  Ventilation:  There  should  be  a  certain  distance  between  inverter  and  other 
objects, to avoid blocking the products vents.
(4) Clean: Do install the products in the dusty, wood chips or other particles , If 
cooling fan is turned on, the particles involved in the inside of the product, thus 
affecting the normal work.
(5)While inverters and batteries connected, will produce arcs or sparks, so there 
should not be around flammable objects such as gasoline, alcohol, etc.

2. Assemble the inverter 
    For this big power inverter, because of the heavier weight, preferably mounted on 
a  solid  platform,  such  as  floor,  table  or  mounting  bracket  fine.  In  order  to  avoid 
falling  off,  platform  for  supporting  the  product  should  can  bear  the  weight  of 
sufficient capacity, and it is good with four screws to secure the product.

Note: 

In case not connected to the remote box, the product can also be used as a 

normal modified sine wave inverter as normal.

3. Remote controller box

Normal working indicator 

Remote interface

Connecting wire

Fault indicator

Power switch

(Switch)

Summary of Contents for PM-1600KAR

Page 1: ...ER Model PM 1600KAR PM 2000KAR PM 2500KAR PM 3000KAR USER S MANUAL Warning This manual contains important safety and operating instruction Please read it carefully before use the unit Service support support giandel com au ...

Page 2: ...19 6VDC 20 2VDC 1800W 1A 0 5A 1 9A 0 8A 1800W 2200W 2200W 30A 6 4 2Kg 30A 3 4 2Kg 30A 8 4 8Kg 30A 4 4 8Kg 2 Item Rated input voltage Continuous power Peak power Input voltage range Input over voltage shut off Input low voltage shut off Input low voltage alarm Output voltage Output frequency Output wave Efficiency Over temperature protection Over load protection Short circuit protection USB output ...

Page 3: ...hstand high temperature such as clothing sleeping bags carpets etc 4 Our power inverter is designed to use with the negative ground electrical system Don t use with positive ground electrical systems The majority of modern automobiles RVs trucks and boats are negative ground 5 Do not disassemble the unit it may cause fire or electric shock 6 Keep the inverter out of reach from children 7 The power...

Page 4: ...t exceeds this value the discharge capacity will be reduced the corresponding discharge time will be shortened than the calculation value this part of the specification can refer to battery manufacturer and whether the battery fully charged will also affect the results 6 CONNECTION 1 Grounding The power inverter has a terminal on the back panel marked Grounding or This is used to connect the chass...

Page 5: ...is too high 3 Connection of the AC appliance Put the power plug of the AC appliance load into the output AC receptacle ofthe inverter directly 8 7 The ground terminal has already connected to the ground wire of AC output receptacle through the internal connecting wire The ground terminal must be connected to the ground wire which will vary depending on where the power inverter is installed In a ve...

Page 6: ...f inverter and remoter to stop working At that time the indicator lights in both inverter and remoter are off The inverter does not consume current from battery when it switched off How to use USB outlet The USB outlet can provide stable 5V DC voltage the maximum current is 1000mA 2400mA which can directly provide power for the portable device with USB port Notice Before use the USB power supply p...

Page 7: ...ar panel s positive and negative electrode to the positive and negative terminal of the solar input of inverter pay attention to the correct polarity 3 Normal charging panel quantity of electric charge indicator lights light up the user can know the size of the battery charging voltage when the full indicator lights up indicating that the battery is fully charged the user should promptly disconnec...

Page 8: ...dition 4 Reduce the ambient temperature 13 2 Under voltage protection The inverter will automatically shut down when the input DC voltage is lower than 9 5V 19V 38V The buzzer will whistle continuously and the green light is off red light is on Please turn off the inverter and use it after recharging the battery 3 Over voltage protection The inverter will automatically shut down when the input DC ...

Reviews: