GIA GIATSU GIA-XK19 Owner'S Manual Download Page 6

Wired Remote Controller 

GIA

-

XK19

3

2.2  Function of the Buttons

Table 2

No.

Name

Function

1

Enter/Cancel

Function selection and cancellation.

2

Ÿ

ķ

 Running temperature setting of the indoor unit, range:16

̚

30

ć 

ĸ

 Timer setting, range:0.5-24 hr.

6

ź

3

Fan

Setting of the high/middle/low/auto fan speed.

4

Mode

Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.

5

Function

Switchover among the functions of Turbo

/

Save/E-heater/Blow etc..

7

Timer

Timer setting.

8

On/Off

Turn on/off the indoor unit.

4+2

Ÿ0RGH

Press them for 5s under off state of the unit to Enter/Cancel the Memory 
function(If memory is set, indoor unit after power failure and then power 
recovery willresume the original setting state. If not, the indoor unit is 
defaulted to be off after power recovery. Memory off is default before 
delivery.).

3

+6

)DQź

By pressing them at the same time under off state of the unit, 

 will be 

displayed on the wired remote controller for the cooling only unit, while 
will be displayed on the wired remote controller for the cooling and heating 
unit.

2

+6

Ÿź

Upon startup of the unit without malfunction or under off state of the 
unit,press them at the same time for 5s to enter the lock state, in which 
case, any other buttons won’t respond the press. Repress them for 5s to 
quit this state.

4+6

0RGHź

Under OFF state, the Celsius and Fahrenheit scales can be switched by 

SUHVVLQJ³0RGH´DQG³ź´IRU¿YHVHFRQGV

5+7

FTimer

Under OFF state, it is available to go to the commissioning status by 

SUHVVLQJ³)XQFWLRQ´DQG³7LPHU´IRU¿YHVHFRQGVDQGOHW³´GLVSOD\HGRQ

the temperature display area by pressing “Mode”, then adjust the options 

ZKLFKLVVKRZQRQWKHWLPHUDUHDE\SUHVVLQJ³Ÿ´DQG³ź´7KHUHDUHWRWDOO\

four options, as follows:

ķ

 Indoor ambient temperature is sensed by the return air temperature 

sensor ( 01 displayed on the timer area).

ĸ

 Indoor ambient temperature is sensed by the wired controller (02 

displayed on the timer area).

Ĺ

 The return air temperature sensor is selected under the cooling, dry, or 

fan mode; while the wired controller temperature sensor is selected under 
the heating or auto mode. (03 is displayed on the timer area).

ĺ

 The wired controller temperature sensor is selected under the cooling, 

dry, or fan mode; while the return air temperature sensor is selected under 
the heating mode. (04 is displayed on the timer display area).

5+7

FTimer

Under OFF state, it is available to go to the commissioning status by 
pressing “Function” and “Timer” for five seconds. Press “Mode” button to 
until “01” icon is shown at the temperature display area. The setting status 

ZLOOEHVKRZQDWWLPHUDUHD3UHVV³Ÿ´DQG³ź´EXWWRQWRDGMXVWDQGWZR

options are available: 

ķ

Three low levels (01) ; 

ĸ

Three high levels (02).

Summary of Contents for GIATSU GIA-XK19

Page 1: ...OWNER S MANUAL WIRED CONTROLLER REMOTE CONTROL ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product GIA XK19 GIA YT1F...

Page 2: ...ctly under the sunlight Never beat throw and frequently disassemble the wired remote controller and the wireless remote controller Never operate the wired remote controller and the wireless remote con...

Page 3: ...4 Fan Setting 4 3 5 Timer Setting 5 3 6 Swing Setting 6 3 7 Sleep Setting 7 3 8 Turbo Setting 8 3 9 E heater Setting 9 3 10 Blow Setting 10 3 11 Other Functions 11 4 Installation and Dismantlement 11...

Page 4: ...Mode Function Timer On Off SHIELD MEMORY MASTER SAVE BLOW QUIET CO2 AUTO TURBO SET HOUR F E HEATER A U T O Fig 1 Outside View of the Wired Remote Controller 1 2 LCD of the Wired Remote Controller SHIE...

Page 5: ...ginal setting state after power failure and then power recovery 11 Master wired remote controller this function is yet unavailable for this unit 12 It blinks under on state of the unit without operati...

Page 6: ...ress Repress them for 5s to quit this state 4 6 0RGH Under OFF state the Celsius and Fahrenheit scales can be switched by SUHVVLQJ 0RGH DQG IRU YH VHFRQGV 5 7 Function Timer Under OFF state it is avai...

Page 7: ...5 On State 3 2 Mode Setting Under the On state of the unit press Mode to switch the operation modes as the following sequence Auto Cooling Dry Fan Heating Auto Cooling Dry Fan Heating 3 3 Temperature...

Page 8: ...Fig 7 3 5 Timer Setting Under the On Off state of the unit press Timer to set timer off on Timer on setting press Timer and then LCD will display xx x hour with hour blinking In this FDVH SUHVV RU WR...

Page 9: ...ig 8 Timer off Setting under the On State of the Unit 7LPHU UDQJH KU YHU SUHVV RI RU ZLOO PDNH WKH VHW WLPH LQFUHDVHG RU GHFUHDVHG E 0 5hr If either of them is pressed continuously the set time will i...

Page 10: ...ng Off When the Swing function is on press Function to enter the Swing setting interface with blinking After that press Enter Cancel to cancel this function Swing setting is shown as Fig 9 Fig 9 Swing...

Page 11: ...p setting interface After that press Enter Cancel to can this function In the Cooling or Dry mode the temperature will increase by 1 after the unit runs under Sleep 1 for 1hr and 1 after another 1hr A...

Page 12: ...approach the setting value In the Cooling or Heating mode press Function till the unit enters the Turbo setting interface DQG WKHQ SUHVV QWHU DQFHO WR FRQ UP WKH VHWWLQJ When the Turbo function is act...

Page 13: ...ote controller enters the Heating mode this function will be turned on automatically Press Function in the Heating mode to enter the E heater setting interface and then press Enter Cancel to cancel th...

Page 14: ...the Blow function is activated press Function to the Blow setting interface and then press Enter Cancel to cancel this function Blow function setting is as shown in Fig 13 Fig 13 Blow Setting Notes Wh...

Page 15: ...r ambient temperature is the sensed at the wired controller 02 in the timer display area Select the temperature sensor at the return air inlet under the cooling dry and fan modes while select the temp...

Page 16: ...r to the 4 pin socket of the indoor unit PCB Tighten the signal wire with ties The communication distance between the main board and the wired remote controller can be up to 20 meters the standard dis...

Page 17: ...nd the soleplate of the wired remote controller 3 Stick the soleplate of the wired remote controller to the wall over the installation hole and WKHQ LW ZLWK VFUHZV 0 4 Insert the four core twisted pai...

Page 18: ...n lines of the wired remote controller must be the shielding twisted pair lines 4 3 Dismantlement of the Wired Remote Controller 1 3 4 2 5 Errors Display If there is an error occurring during the oper...

Page 19: ...ole unit over current protection E5 Compressor demagnetization protection HE Over phase current protection P5 PFC protection Hc Compressor desynchronizing H7 IPM Temperature Protection P8 IPM Current...

Page 20: ...which is not available for the corresponding function the unit will keep the original running status 1 Function of Press Buttons Fig 17 1 ON OFF Press this button to turn on off the unit After that t...

Page 21: ...imer value 6 LIGHT Light On and Light Off can be set by pressing this button when the unit is at On or Off status After powered on the default is Light On 7 TURBO In Cool or Heat mode pressing this bu...

Page 22: ...me increased or decreased by 1 minute If the button is pressed down for more than 2 seconds the time will be changed quickly in VXFK D ZD UVWO WKH YDOXH RQ WKH RQH V SODFH LV FKDQJHG DQG WKHQ LV WKH Y...

Page 23: ...nit the whole unit will be stopped completely b About AFTERHEAT X FAN Under the Heat mode or Auto Heat mode if the unit is turned off the compressor and outdoor fan will stop running immediately and t...

Page 24: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...