GIA GIADB40X6PW Owner'S Manual Download Page 8

6

7

IDENTIFICATION  OF  PARTS

Power Cord and plug

Continuous drain hose outlet

Power cord buckle (placed in the water bucket,

used only when storing the unit. Installed as 

shown Fig.3a))

Front

Rear

Caster

Identification of parts

Fig.2

Fig.3

Control panel

1
2
3
4

5

1
2

3

4

NOTE:

 

All the pictures in the manual are 

for explanation purposes only. The actual 

shape of the unit you purchased may be 

slightly different, but the operations and 

functions are the same.

             

OPERATING  THE  UNIT

When using the unit

 When first using the dehumidifier, operate the unit

 continuously 24 hours. Make sure the plastic cover on

 the continuous drain hose outlet install stightly properly

 so there are no leaks. 

This unit is designed to operate with a working 

O

O

O

O

environment between 5 C/41 F and 35 C/95 F.

If the unit has been switched off and needs to be 

switched on again quickly, allow approximately

three minutes for the correct operation to resume.

Do not connect the dehumidifier to a multiple socket 

outlet, which is also being used for other electrical 

appliances.

Select a suitable location, making sure you have easy 

access to an electrical outlet.

Plug the unit into a  electrical socket-outlet with earth 

connection.

Make sure the Water bucket is correctly fitted otherwise 

the unit will not operate properly.

NOTE:

When the water in the bucket reaches to a certain 

level,please be careful to move the machine to avoid it 

falling down.

Casters(At four points on the bottom of unit)

    

Casters can  move freely.

    Do not force casters to move over carpet, 

    nor move the unit with water in the bucket.

    (The unit may tip over and spill water.)

 A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed

 storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

20cm or more

20cm or more

40cm or more

20cm or more

40cm or 

more

Positioning the unit

 Do not use outdoors.

 This dehumidifer is intended for indoor residential 

 applications only. This dehumidifier should not be used

 for commercial or industrial applications.

 Place the dehumidifier on a smooth, level floor strong

 enough to support the unit with a full bucket of water.

 Allow at least 20cm of air space on all sides of the unit

 for good air circulation (at least 40cm of air space on

 air outlet).

 Place the unit in an area where the temperature will not

 fall below 5 C(41 F). The coils can become covered with 

 frost at temperatures below 5 C(41 F), which may reduce

 performance.

 Place the unit away from the clothes dryer, heater or radiator.

 Use the unit to prevent moisture damage anywhere books

 or valuables are stored.

 Use the dehumidifier in a basement to help prevent 

  moisture damage.

 The dehumidifier must be operated in an enclosed

 area to be most effective.

 Close all doors, windows and other outside openings

 to the room.

Fig.4a

Accessories:(placed in the water bucket of the unit)

pump drain hose(1pc) (only for the unit with pump featrue)                          

power cord buckle(1pc)                  female threaded end(1pc)(on some models)

Pump drain hose outlet(some models without)

5

1

3

4

5

2

1

2

3

5

4

6
7

Panel
Water bucket
Water level window
Handle (both sides)

6

7

Air outlet grille

Air filter 

Insert the power cord buckle

into the unit.

Fig.3a

Air outlet grille

Summary of Contents for GIADB40X6PW

Page 1: ...OWNER S MANUAL DEHUMIDIFIER X6WE GIADB40X6PW GIADB50X6PW ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product...

Page 2: ...user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the use...

Page 3: ...ck of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the applianc...

Page 4: ...d Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTION...

Page 5: ...echnician Do not place flower vases or other water container on top of the unit The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data spe...

Page 6: ...e bucket is full the pump starts to work Refer to the next pages for removing the collected water Do not use this operation when the outdoor temperature O O is equel to or less than 0 C 32 F 2 COMFORT...

Page 7: ...re The system starts to count the time once the fan motor operates The check filter feature can be only activated when the accumulated operation time achieves 250 hours or more The Reset light Clean f...

Page 8: ...anation purposes only The actual shape of the unit you purchased may be slightly different but the operations and functions are the same Accessories placed in the water bucket of the unit pump drain h...

Page 9: ...ater in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there...

Page 10: ...reinstall the pump hose properly to the unit before replace the bucket into the unit see Fig 8 When you remove the bucket if there is some water in the unit you must dry it When the unit is on if the...

Page 11: ...wn to let the water flow smoothly Do never let it up Select the desired humidity setting and fan speed on the unit for pump draining to start Pump drain hose Pump drain hose outlet NOTE The pump opera...

Page 12: ...and cleaning of the dehumidifier Turn the dehumidifier off and remove the plug from the wall outlet before cleaning 1 Clean the Grille and Case Use water and a mild detergent Do not use bleach or abr...

Page 13: ...other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating...

Page 14: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Reviews: