OWNER’S
MANUAL
CONSOLE
ENGLSI
H
M
01
GIA-M
F
I-09M01 |
GIA-
I-12M01
I-18M01
I-
Thanks for choossing our product.
Please, read carefully this manual
before using the product
Page 1: ...OWNER S MANUAL CONSOLE ENGLSIH M01 GIA MFI 09M01 GIA MFI 12M01 GIA MFI 18M01 I Thanks for choossing our product Please read carefully this manual before using the product...
Page 2: ...iance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance External static pressures at the appliance was tested is 0 Pa Fuse link...
Page 3: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...
Page 4: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...
Page 5: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...
Page 6: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance...
Page 7: ...purpose Precautions WARNING place only the qualified person can perform the work Otherwise it may cause personal injury or damage If you need to relocate the air conditioner to another must be install...
Page 8: ...S 14 Indoor Unit ON OFF switch 3XVK WKLV VZLWFK RQFH WR VWDUW RSHUDWLRQ Push once again to stop it 2 Air outlet 3 Display 4 Front panel 5 Louvers vertical blades 7KH ORXYHUV DUH LQVLGH RI WKH DLU RXWO...
Page 9: ...peration mode AUTO COOL DRY FAN HEAT Press it to increase temperature setting W F without this function Press it to decrease temperature setting FAN Press it set swing angle QUIET SWING CLOCK X FAN TE...
Page 10: ...reases set temperature In AUTO mode set temperature is not adjustable Press this button to increase set temperature Holding it down above 2 seconds rapidly increases set Auto Medium speed Low Medium s...
Page 11: ...of original factory 2 hours or 3 hours or 8 hours the place of setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink temperature display will resume...
Page 12: ...EAT mode Press this button to activate deactivate the Turbo function which enables the unit to reach the preset temperature in the shortest time In COOL mode the unit will blow strong Press and button...
Page 13: ...rt them after 30 seconds If it still can t operate properly Notes replace the batteries Sketch map for replacing batteries Replacement of Batteries At unit OFF press MODE and buttons simultaneously to...
Page 14: ...UW WKH IURQW SDQHO LQWR WKH JURRYHV RI WKH XQLW SODFHV 3UHVV WKH FODZV RQ WKH ULJKW DQG OHIW RI WKH DLU ILOWHU GRZQ VOLJKWO then pull upward 3 Take off the Titanium Apatite Photocatalytic Air Purifyin...
Page 15: ...ILOWHUV PD UHVXOW LQ WURXEOHV DV GXVW ZLOO DFFXPXODWH inside the indoor unit I WKH GXVW GRHV QRW FRPH Rff easily wash them with neutral detergent thinned with lukewarm water then dry them up in the s...
Page 16: ...period Check 127 Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoo...
Page 17: ...t temperature decreased its cooling capacity will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat...
Page 18: ...ffuse cool air Clean the air filter every week for higher efficiency Close window and door while operating the unit to prevent leakage of cooled air to save energy Draw close curtains or close glass w...
Page 19: ...long time cut off the power supply main switch Do not insert objects into the air inlet or outlet when the airconditioner is running as it may cause damage or personal injury Also pay special attenti...
Page 20: ...amaged check if breaker switch is still on Check if the power supply is in order Check if the timer switch is on or not Check if the preset temperature is too high Check if the sunlight shines directl...
Page 21: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...