background image

16

 

         

17

LIMITED WARRANTY:

This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any

defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either 

provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers

as directed by GHP Group, Inc., within one (1) year of retail purchase. (Shipping costs, labour costs, etc. are the responsibility of the purchaser.)

DUTIES OF THE OWNER:

This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse

the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled

check or payment record must be kept to verify purchase date and establish warranty period. Original carton should be kept in case of warranty

return of unit.
WHAT IS NOT COVERED:

1.

Damage resulting from use of improper fuel.

2.

Damage caused by misuse or use contrary to the owners manual and safety guidelines.

3.

Damage caused by a lack of normal maintenance.

4.

Fuses

5.

Use of non-standard parts or accessories.

6.

Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.

This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of

routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of
maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM
GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.

THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,

INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE

REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL

GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. 

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not

allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.

CLAIMS HANDLED AS FOLLOWS:

1. Contact your retailer and explain the problem.

2. If the retailer is unable to resolve the problem, contact ourCustomer Service Dept. detailing the heater model, the problem, and proof

of date of purchase.

3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY

AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.ghpgroupinc.com

NAME: ______________________________________ PHONE: (

) __________________ EMAIL: ____________________________

ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________

MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________

DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________

CITY & STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________

Please Take a Minute To Give Us Your Answers To The Following Questions.

All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.

Who primarily decided this purchase?

Male

Female

18-24

25-39

40-59

60 and over

Purpose of Purchase? _______________________________________________________________________________________________

Do you own any other portable heaters? Yes No If yes, type____________________________brand_____________________

How do you intend to use your new heater?

Construction Site

Farm

Warehouse/Commercial

Garage/Outbuilding Other

How did you become aware of this heater?

In-Store Display

Newspaper Ad

Magazine Ad

Friend/Relative

TV Commercial

Store Salesperson Other ___________________________

What made you select this heater?

Style

Size/Portability

Price

Package

Brand

Other ___________________

Do you:

own

rent Would you recommend this heater to a friend?

Yes

No

Please give us your comments:________________________________________________________________________________________

THANK YOU FOR COMPLETING THIS FORM!

Information will be held confidential.

WARRANTY

Summary of Contents for Dyna-Glo Pro RA18LPDGP

Page 1: ...th this heater can result in death serious bodily injury and property loss or damage from the hazards of fire explosion burn asphyxiation carbon monoxide poisoning and or electrical shock Only persons who can understand and follow the instructions should use or service this heater If you need assistance or heater information such as an instruction manual labels etcetera contact the manufacturer CA...

Page 2: ... VEHICLE USE WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS PROPANE CONSTRUCT...

Page 3: ...st particles or unknown chemicals WARNING If the information in this manual is not followed exactly a fire OR Explosion may result causing property damage personal injury or loss of life WARNING a Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance a An LP cylinder not connected for use shall not be stored in the vicinity of this or any...

Page 4: ...minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure respectively Use only the regulator hose assembly provided with the heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or hose is cut replace with regulator hose assembly listed on the parts list prior to using this heater Gas supply co...

Page 5: ...Vapor Only PRODUCT FEATURES PROPANE CONSTRUCTION HEATER Size Assembled High Medium Low Maximum Minimum lbs hr kg hr L X W X H RA18 Series 18 000 12 000 6 000 Bottle Pressure 5psi 11 0 WC 0 83 0 28 0 377 0 127 16 8 lbs 7 6 kg 15 75 x14 96 x23 35 400x380x593mm Weight Input Rating BTU Hr Manifold Pressure Gas Consumption Supply Pressure Model Locking Front Caster Rear Caster Back Cover Handle Slot Sa...

Page 6: ...er on each of the threaded portions of the caster see Figure 1 9 Thread the casters into the four threaded holes in the base of the unit by turning them clockwise The locking casters should be placed at the front of the unit and the other two at the back of the unit See Figure 1 10 Tighten The casters using the wrench supplied with the casters 11 Install 20 lb propane cylinder see Propane Supply s...

Page 7: ...id knocking the cylinder over on its side with the hose regulator connected as this can cause damage to the regulator diaphragm Never store a propane LP cylinder indoors or in the vicinity of any gas burning appliances Protect the cylinder valve and handle it with care Be sure that the shut off valve is closed tightly after each use Be sure to protect the POL fitting from damage when disconnected ...

Page 8: ...outlet Turn the fitting counterclockwise into the threads of the cylinder valve Some models have a hand wheel that can be slid off the nut so that a wrench can be used to tighten the fitting if desired CAUTIONPosition the regulator such that the side with the tower is facing down and the flat side is facing up See Figure 2 WARNINGEnsure that the gas hose is not touching the unpainted heat shield a...

Page 9: ...cted from the propane tank Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING GARAGE OR ANY OTHER ENCLOSED AREA CHECKING FOR LEAKS Check all gas connections with a soap solution to be sure they are tight and leak proof Soap bubbles indicate gas leakage that must be corrected The installation of y...

Page 10: ...depress for 5 seconds B Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for at least 30 seconds This will allow air to bleed from the gas system 6 Depress control knob while depressing the piezo ignitor button This should cause the spark from the piezo ignitor to light the pilot gas Keep control knob depressed thirtry 30 seconds ...

Page 11: ...ldren If for any reason the heater is to be stored indoors the tank must be disconnected and stored outdoors in a well ventilated area out of reach of children in accordance with the standard for the the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code The plastic tank valve plug supplied with your tank must be tightly installe...

Page 12: ...rect Note Do not mistake orange flames with yellow tipping Dirt or dust particles may enter the burner flames and cause transient patches of orange flame Burner and ODS Pilot Cleaning Clean the exterior with soft bristle brush vacuum cleaner or pressurized air Never use a wooden toothpick as it may break off and clog the ODS pilot or main burner port Use a flashlight to inspect the main burner inl...

Page 13: ...te repeat ignition operation 3 Contact your gas company gas supplier or qualified service technician 4 Replace thermocouple 5 Hand tight until snug then tighten 1 4 turn with a wrench 6 Replace gas control Burner does not light after ODS pilot is lit 1 Burner orifice clogged 2 Gas supply pressure is very low 1 Clean burner orifice 2 Contact gas supplier Delayed ignition 1 Main burner carry over po...

Page 14: ...odor during combustion 1 Foreign matter in gas or on burner ports 2 Heater burning vapors form paint impurities in air 3 Gas leaks refer to front page Warnings 1 Check gas passage way and burner 2 Ventilate room stop storing and using odor causing products near heater 3 Locate and correct leaks immediately Heater shuts off on ODS 1 Not enough fresh air is available 2 Low gas pressure 3 ODS pilot p...

Page 15: ...11B 2 13 Rear Chassis PT N11B 4 5 ODS Assembly PT N11B 6 14 Castor With Lock PT N06 33 6 Burner Assembly PT N11B 4 15 Castor Without Lock PT N06 32 7 Gas Valve PT N11B 13 16 Heat Insulation Board PT N11 6 8 Piezo Ignitor PT N11B 5 17 Back Cover PT N11B 2 1 9 Knob Base PT N11B 10 18 Knob PT N06 24 Item Model Number Part No Item Model Number Part No RA18 SERIES WARNING This heater is not intended fo...

Page 16: ... and Hose Assembly 7 Gas Valve 6 Burner Assembly 2 Guard Assembly 11 Gas Pipe 14 Caster With Lock 10 Tilt Switch 15 Caster Without Lock 16 Heat Insulation Board 8 Piezo Ignitor 9 Knob Base 4 Reflector 1 Lower Shield 3 Front Panel EXPLODED PARTS DRAWING 5 ODS Assembly 18 Knob ...

Page 17: ... how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem contact ourCustomer Service Dept detailing t...

Page 18: ...entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www g...

Reviews: