background image

IMLPF300DGD - KIO

Operating Instructions & Parts Manual

 

RMC-FA300DGD

Dyna-Glo

TM

 Delux

Propane Construction Heater

PROFESSIONAL GRADE

Description

Dyna-Glo

TM

 Delux Model RMC-FA300DGD heaters are 300,000 BTU/Hr construction 

heaters. This heater uses propane gas for combustion, and electricity to run the 
fan. It is primarily intended for temporary heating of well-ventilated buildings 
under construction, alteration or repair. This heater should be utilized in sheltered, 
well-ventilated areas, but never in occupied dwellings.

C           US

C                        US

Figure 1 - Model RMC-FA300DGD 

  

Output Rating 

 

Maximum Fuel 

 

Regulator 

 Model 

BTU/Hr 

Fuel 

Consumption 

Ignition 

Outlet Pressure

RMC-FA300DGD 

300,000 

Propane Vapor Only 

13.9 lb/h 

Direct Spark, Interrupted 

  7-10 PSIG

  

Hot Air Output  

Minimum Supply 

Maximum Supply 

Size 

 

 Model 

Approx. (CFM)  Motor 

Pressure to Regulator 

Pressure to Regulator  L x W x H (Inches) 

RMC-RMC-

FA300DGD                    1800 

0.085 HP 

25 PSIG (For purposes            Max Bottle Pressure 

33.7 x 12.6 x 20.5 

  

 

1,720 RPM 

of input adjustment) 

 

 

Table of Contents 

Page

Description  . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . .1
Unpacking . . . . . . . . . . . . . . . . . . . . . . .  1
General Safety Information . . . . . . . . 1-3
Theory of Operation. . . . . . . . . . . . . . . .3
Installation. . . . . . . . . . . . . . . . . . . . . . 3-4
Ventilation. . . . . . . . . . . . . . . . . . . . . . . .4
Operation  . . . . . . . . . . . . . . . . . . . . . . 4-5
Maintenance . . . . . . . . . . . . . . . . . . . . 5-6
Storage  . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring Diagram. . . . . . . . . . . . . . . . . . . .6
Repair Parts Illustration
and Parts List . . . . . . . . . . . . . . . . . . . . 7-8
Air Quality Hazard Warning  . . . . . . . . .9
Troubleshooting Chart . . . . . . . . . . . . .10
Warranty  . . . . . . . . . . . . . . . . . . . . . . . .12

Unpacking

1. Unpack all materials used to protect 

the heater inside of carton. Retain 

plastic caps attached to exposed 

fittings for use during storage.

2. Remove heater, accessories and all 

hardware from carton.

3. Inspect all items for damage that may 

have occurred during shipment.

GENERAL HAZARD 

WARNING

FAILURE TO 

COMPLY WITH THE PRECAUTIONS AND 

INSTRUCTIONS PROVIDED WITH THIS 

HEATER, CAN RESULT IN DEATH, SERIOUS 

BODILY INJURY AND PROPERTY LOSS, 

OR DAMAGE FROM THE HZARARDS OF 

FIRE, EXPLOSION, BURN. ASPHYXIATION, 

CARBON MONOXIDE POISONING, AND/

OR ELECTRIC SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND 

AND FOLLOW THE INSTRUCTIONS 

SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER 

INFORMATION SUCH AS AN INSTRUCTION 

MANUAL, LABELS, ETCETERA, CONTACT 

THE MANUFACTURER.

General Safety Information

IMPORTANT: Be sure to read and 

understand all cautions and warnings, 

before operating this heater. Keep 

this instruction manual for future 

reference, and use it as a guide to safe 

and proper operation of the heater. 

Various precautions appear throughout 

this manual. Please review and pay 

close attention to them. Below is an 

explanation of the various levels of 

caution required while operating this 

heater.

DANGER

Indicates  an  im minen tly 

hazardous situation 

which, if not avoided, WILL result in death 

or serious injury.

WARNING

Indicates a poten tially 

hazardous situation 

which, if not avoided, COULD result in 

death or serious injury.

CAUTION

Indicates a poten tially 

hazardous  situa tion 

which, if not avoided, MAY result in minor 

or moderate injury.

WARNING

FIRE, BURN, 

INHALATION, AND 

EXPLOSION HAZARD, KEEP SOLID     
COMBUSTIBLES, SUCH AS BUILDING 

  

 Model 

 Electrical Input 

Amperage 

RMC-FA300DGD       120 V, 60 Hz 

      0.65

Electrical Specifications

General Specifications

WARNING

(6.3 kg/h)

(85.6 x 32 x 52.1 cm)

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and 
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for 
future reference.

Specifications

Printed in China

www.ghpgroupinc.com

ANS Z83.7-2017 CSA 2.14-2017 CONSTRUCTION HEATER

RMC-FA300DGD

Summary of Contents for Dyna-Glo Delux Series

Page 1: ...ROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM THE HZARARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL LABELS ETCETERA CONTACT THE MANUFA...

Page 2: ...of combustion generated by the heater are forced through the heater and released into the area being heated This heater operates at approximately 98 combustion efficiency but still produces a small amount of carbon monoxide Humans can tolerate small amounts of carbon monoxide for short periods Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result i...

Page 3: ...r assembly runs from the propane supply to the heater itself After the gas runs through the hose and regulator it passes through the solenoid valve and out the nozzle into the combustion chamber AIR SYSTEM The internal motor turns the fan which pushes air around and through the combustion chamber Here the air is heated and provides a constant stream of warmth IGNITION SYSTEM The spark module sends...

Page 4: ... ghpgroupinc com Dyna GloTM Figure 4 Hose and Inlet Connector Hose Inlet Connector Installation Review and under stand all of the warnings in the Safety Information Section on pages 1 3 They are required to operate this heater safely Follow all local and state codes when operating this heater After installing all gas piping and making the proper connections be sure to check for leaks Apply a 50 50...

Page 5: ...hey are open Check the fuel level in the propane tanks If the level is too low replace the tank with a full one If heater still does not restart contact your nearest Service Center Maintenance Do not attempt to service the heater while it is hot operating or plugged in Severe burns or electrical shock can occur 1 Be sure to inspect the heater before each use Check for leaks using the method descri...

Page 6: ...nal wiring as supplied with the heater must be replaced it must be replaced with type AWG105 C wire or its equivalent except as indicated Type SF2 200 SGI 250 C Green Chassis Ground Black Back Pressure Switch Figure 7 Fan Cross Section Fan Setscrew Motor Shaft Hub Figure 8 Wiring Diagram For Technical Support or Troubleshooting Call 1 877 447 4768 6 For Technical Support or Troubleshooting Call 1 ...

Page 7: ...27 28 32 29 31 30 33 34 35 36 38 39 42 37 40 41 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 24 23 22 12 20 14 13 15 16 17 18 19 21 7 9 10 11 8 26 For Technical Support or Troubleshooting Call 1 877 447 4768 ProFitterTM Dyna GloTM Operating Instructions and Parts Manual 7 For Technical Support or Troubleshooting Call 1 877 447 4768 8 30 am 4 30 pm CST www ghpgroupinc com Dyna GloTM Delux Operat...

Page 8: ...5 2 29 Clip 2301973 1 30 Screw 2000375 1 31 Nut 2000231 1 32 Capacitor 2201586 1 33 Bushing Strain Relief 2101633 1 34 Power Cord Assembly 2201163 1 35 Switch 2201549 1 36 Solenoid Valve 2315449 1 37 Screw 2001206 2 38 Connector Inlet 2315595 1 39 Fitting 2315596 1 40 Solenoid Valve Bracket 2315594 1 41 Screw 2000416 2 42 Nut 2000384 2 43 Back Pressure Switch 2201594 1 44 Base Lower 2315589 1 45 S...

Page 9: ...yna Glo TM Propane Construction Heater RMC FA300PF DG DGD Symptom Possible Cause s Corrective Action Fan does not turn when electrical connection is made Heater will not fire Heater quits while running 1 No electric power to heater 2 Fan blade contacts inside of heater housing 3 Fan blade s bent 4 Fan motor defective 1 No spark at igniter 2 Improper spark gap 3 Bad electrode 1 Internal temperature...

Page 10: ...rts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS W...

Page 11: ... Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem cont...

Page 12: ...ou can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here Tel 877 447 4768 www ghpgroupinc com GHP Group Inc 6440 W Howard St Niles IL 60714 3302 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 ...

Reviews: