8 | Technical data 

G 1910 series 

Technical data 

 


G 1910-02 

 

Measuring range (specified accu-
racy) 

0 .. 2000 ppm 

0.000 .. 0.200 % 

Measuring range (not specified) 

 

0.000 .. 1.000 % 

Accuracy 

± 70 ppm ± 3 % measurement 

Measuring cycle 

2 seconds 

Display 

3-line segment LCD, additional symbols, illumi-
nated (adjustable white, permanent illumination) 

Additional functions 

Min/Max/Hold 

TWA calculation / STEL 

2-stage alarm (optical and acoustic) 

Adjustment 

1-point, 2-point and basic sensor adjustment 

Housing 

 

Break-proof ABS housing 

Protection rating  IP30 

Dimensions 
L*W*H [mm] and 
weight 

108 * 54 * 28 mm without measuring cell or kink 
protection 

180 g, incl. battery and measuring cell 

Operating conditions 

0 to 50 °C; 0 to 85 % r.h. (non-condensing) 

Storage temperature 

-20 to 70 °C 

 

 

Summary of Contents for GREISINGER G 1910 Series

Page 1: ...Quick reference guide G 1910 series Compact CO2 monitor with alarm EN...

Page 2: ...t at a glance 9 3 1 The G 1910 series 9 3 2 Display elements 9 3 3 Operating elements 9 3 4 Connections 10 4 Measurement Basics 10 5 Operation and maintenance 11 5 1 Operating and maintenance notices...

Page 3: ...Table of contents B H90 0 0X DK2 2 1 3 24 9 Service 24 9 1 Manufacturer 24...

Page 4: ...first time 1 2 Legal notices This document is entrusted to the recipient for personal use only Any impermissible transfer duplication translation into other languages or excerpts from this operating m...

Page 5: ...e to the device or to the environment in case of non observance _ NOTE This symbol indicates processes which can have a direct influence on operation or can trigger an unforeseen reaction in case of n...

Page 6: ...nostic or other medical purposes on pa tients The product is not intended to come into direct contact with food For measurements requiring devices that are subject to authorisation or special approval...

Page 7: ...lse rate 2 0 20 000 1 0 10 000 Possible shortness of breath 0 5 5000 TWA Maximum for working condi tions 0 1 0 2 1000 2000 Recommended maximum value in public areas 0 04 400 Fresh air Product is not p...

Page 8: ...viron ments with slightly elevated CO2 concentrations in areas that are not harmful to the health It is designed to be carried on the body for mobile use The user can be warned optically and acoustica...

Page 9: ...s display Evaluation of the charge status _ Unit display Display of units or type of mode min max hold _ Main display Measurement of the current CO2 value _ Auxiliary display Display of the mean value...

Page 10: ...ue of the current measure ment Both simultaneously Rotate display overhead display _ Function key Press briefly Freeze measurement Hold Return to measurement display Call up next parameter Long press...

Page 11: ...a basic sensor adjustment must be carried out _ NOTE The product must be handled with care and used in accordance with the technical data Do not throw or strike _ NOTE If the product is stored at a t...

Page 12: ...rating manual 5 3 CO2 calibration _ For additional information refer to the operating manual In order to improve the accuracy the carbon dioxide sensor can be calibrated In order to conduct a CO2 cali...

Page 13: ...Function key for 4 seconds to start the calibration ONF appears in the display first then AL 2 1 point or 2 point calibration is started This depends on what was adjusted in the Expanded settings men...

Page 14: ...e specifications on the analy sis certificate must always be observed NOTE For information about the available calibration settings refer to Configuring parameters of the configuration menu After the...

Page 15: ...ppears in the display Release the Function key _ Parameter Values Meaning _ Input INP CO2 measurement in PPm CO2 measurement in ppm _ Alarms AL OFF No active alarm ON Alarm alerting via text display a...

Page 16: ...value INP _ G 1910 02 AL 1 1 000 in Max alarm limit the main alarm is triggered when the value is exceeded G 1910 02 AL 1 10000 in ppm Max alarm limit the main alarm is triggered when the value is ex...

Page 17: ...ight L TE OFF Backlight deactivated 0 15 0 30 1 00 4 00 Automatic shut off of the backlight after a selected time in minutes and seconds during which no but tons have been pressed ON No automatic shut...

Page 18: ...clear characters or no re sponse when but tons are pressed Rechargeable bat tery depleted System error Product is defective Rechargeable bat tery depleted Error in the product Product is defective Cha...

Page 19: ...Sensor defect Perform sensor adjustment Send in for repair ERR 7 Sensor error Defective sensor ad justment Sensor defect Perform sensor adjustment Send in for repair ERR T Temperature error Permissib...

Page 20: ...nal symbols illumi nated adjustable white permanent illumination Additional functions Min Max Hold TWA calculation STEL 2 stage alarm optical and acoustic Adjustment 1 point 2 point and basic sensor a...

Page 21: ...cro USB socket not a data connection Auto power OFF function The device switches off automatically if this is acti vated Directives and standards The devices conform to the following Directives of the...

Page 22: ...illumi nated adjustable white permanent illumination Additional functions Min Max Hold TWA calculation STEL 2 stage alarm optical and acoustic Adjustment 1 point 2 point and basic sensor adjustment H...

Page 23: ...Micro USB socket not a data connection Auto power OFF function The device switches off automatically if this is acti vated Directives and standards The devices conform to the following Directives of t...

Page 24: ...9 Service 9 1 Manufacturer If you have any questions please do not hesitate to contact us GHM Messtechnik GmbH GHM GROUP Greisinger Hans Sachs Str 26 93128 Regenstauf GERMANY Email info greisinger de...

Reviews: