5.3.7 Connecting a counter signal
When configuring the device you can select 3 different input signal modes similar to the connection of
frequency- and rotation-signals
.
The connection of a sensor-signal for a counter-signal is the same used for the frequency- and rotation-
signal
.
Please use the wiring diagram given in this chapter.
There is the possibility to reset the counter. When connecting contact 4 with GND (e.g. contact 6) the
counter will be reset. You can do this manually (e.g. with the help of a push-button) or automatically
(with one switching output of the device).
When connecting the device, take care not to exceed the limits of the input-
voltage or the input-current of the frequency input.
+