11
Rear grills
Electric heating element
Insulated air pipe (outlet)
Air pipe (inlet)
Wall bracket
Air conditioner
Internal condensate
drainage pipe
The pipe protection grills must be
applied outside the wall where the unit is
installed. Cut part of the right grill
(looking at the unit from the rear) in
order to permit the condensate drainage
pipe to exit correctly (see Figure).
10. Connect the air conditioner to the
power supply by plugging in the plug.
Before starting, make sure that the plug
is adequate to the air conditioner's
power absorption and the regulations in
force.
9. Rear grills
At the end of installation operations, the grills must be applied to the air circulation pipes.
As above, this particular measure will ensure better unit operation because not only will the air be filtered and therefore the heat
exchange system will remain cleaner (and maintain yield over a longer period of time), but will also prevent the deposit of leaves or
other clogging material in the pipes and infiltration by birds or other small animals.
These grills can be quickly removed and cleaned whenever necessary.
AIR SUCTION
VIEW OF AIR CONDITIONER REAR GRILLS
AIR EXPULSION
CONDENSATE
DRAIN
9
8. Installation of the unit
IMPORTANT
: handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will remain
in view.
IMPORTANT
: whenever the opening in the wall made for the unit is not equipped for the connection to the electrical power supply,
remember to make an adequate opening in the wall for the exit of the air conditioner's power supply cable.
Insert the unit into the recess made in the wall and pass the condensate drainage hose along the air expulsion pipe and check the stabi-
lity of the air conditioner. Push the unit in towards the wall behind it.