Summary of Contents for PDC series

Page 1: ...INSTALLATION MANUAL GHIBLI PDC DETRAZIONE FISCALE ALTA EFFICIENZA RISPARMIO ENERGETICO INSTALLAZIONE FACILE ENERGIA RINNOVABILE DIMENSIONI COMPATTE FUNZIONE A BASSA TEMPERATURA VENTILAZIONE SILENZIOSA AUTORESTART DI SERIE GAS ECOLOGICO ...

Page 2: ...2 ...

Page 3: ...EXPLAIN THE UNIT S OPERATION TO THE CLIENT USING THE OPERATION AND MAINTENANCE MANUAL GIVE THE OPERATION AND MAINTENANCE MANUAL TO THE CUSTOMER THE UNIT INSTALLATION IS FOR QUALIFIED STAFF ONLY THE UNIT MUST BE INSTALLED FOLLOWING THE NATIONAL REGULATIONS THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTER THE UNIT INSTALLATION IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE SUBSTITUTED EXCLUSIVELY BY ...

Page 4: ...tion E The rear ventilation grills must be free from obstacles to permit a free flow of air F Make sure that the flow of air expulsed from the rear grills does not disturb the neighbours and is not directed to an area with a continuous passing of pedestrians G The flow of air from the rear grills must not be sent into a closed room because if this expulsed air is injected into an area without free...

Page 5: ...es all the information found in the respective chapters that explain the various types of installation possible Wall installation page 6 Built in installation page 9 section section Installation to the edge of the wall page 12 section Wall bracket Wall bracket ...

Page 6: ...pulsion making sure that the pipe lined with condensate proof material can be fitted into hole A as shown in Figure 1 N B The air inlet and outlet pipes supplied have a maximum length of 400 mm for this reason if the depth of the wall is less these pipes must be cut For installations with pipes longer than 400 mm please contact your neare st Technical Assistance Center or your Manufacturer s techn...

Page 7: ...inside the condensate drainage in order to prevent water from freezing insi de the pipe in low temperature installations Cut the length of pipe as required depending on how far it must protrude outside bearing in mind that it must protrude from the air hosing sealing grill by 1 cm IMPORTANT make sure that the downward inclination of the condensate drainage outwards is in the range of from 4 to 5 f...

Page 8: ...t be applied to the air circulation pipes As above this particular measure will ensure better unit operation because not only will the air be filtered and therefore the heat exchange system will remain cleaner and maintain yield over a longer period of time but also will prevent the deposit of leaves or other clogging material in the pipes and infiltration by birds or other small animals These gri...

Page 9: ... The air inlet and outlet pipes supplied have a maximum length of 400 mm for this reason if the depth of the wall is less these pipes must be cut For installations with pipes longer than 400 mm please contact your nearest Technical Assistance Center or your Manufacturer s technical commercial con tact person 5 Make sure that the air expulsion pipe hole A in Figure 2 is lined with con densate proof...

Page 10: ...event water from freezing inside the pipe in low temperature installations Cut the length of pipe as required depending on how far it must protrude outside bearing in mind that it must protrude from the air hosing sealing grill by 1 cm IMPORTANT make sure that the downward inclination of the condensate drainage outwards is in the range of from 4 to 5 fig 8 slowly pour water into the condensing uni...

Page 11: ... therefore the heat exchange system will remain cleaner and maintain yield over a longer period of time but will also prevent the deposit of leaves or other clogging material in the pipes and infiltration by birds or other small animals These grills can be quickly removed and cleaned whenever necessary AIR SUCTION VIEW OF AIR CONDITIONER REAR GRILLS AIR EXPULSION CONDENSATE DRAIN 9 8 Installation ...

Page 12: ...tion the power supply cable must be substituted with a flexible cable with polychloro prene sheath like H05RN F or H07RN F Make sure that there are no electric hoses or gas or water pipes inside the parts of the wall to be drilled IMPORTANT THE UNIT MUST BE INSTALLED FOLLOWING THE NATIONAL REGULATIONS 1 Position the supplied paper template on the wall and using a pencil mark the position of the ha...

Page 13: ...e resins in order to avoid the water and the insect entrance 5 Place along the frontal A and rear B side a thermal noise proof material thickness 50 mm in order to avoid noise air and heat passage from the unit to the room and outdoor ambient and viceversa see fig 3 6 Condensate drain preparation Assemble the condensate drainage pipe by firmly pushing and twisting it towards the air conditioner se...

Page 14: ...erating problems short circuits or other malfunc tions to the unit In order to reduce the length of the electric heating element just pull it inside the unit as shown in fig 6 7 7 1 7 2 7 3 Whenever the unit must be removed make sure to first drain the condensate collection tray to avoid annoying water spills During transport always leave the air condi tioner positioned upright on a flat surface a...

Page 15: ...in the continuity tank could last up to 5 6 hours depending on the ambient humidity When it is exhausted the user can fill the conti nuity tank then the air conditioner restarts working at HIGH EFFICIENCY The Drain exit must be closed the auxiliary Extra drain outlet is connected to the pump in order to recover the dew created on the evaporator and eliminate it by evaporation on the condensers ONL...

Page 16: ...THE CONDENSATE DRAINAGE AND VENTILATION HOLES THE OUTLINE REGARDS THE UNIT S REAL PERIMETER AND NOT THE OPENING TO BE MADE IN THE WALL WHICH MUST CONSEQUENTLY BE INCREASED BY 10 MM ON EACH SIDE AND 20 MM IN HEIGHT IMPORTANT THESE DIMENSIONS ARE IN MILLIMETERS 304 373 ...

Page 17: ...lass surface insert adequate vibration damping shims to prevent both the vibration of the structure and the crushing of the condensate drainage pipe Connect to this rubber pipe an extension pipe that permits the excess condensate created by the unit towards a special drain or into a temporary collection tray THAT MUST BE REGULARLY CHECKED AND DRAINED IMPORTANT incorrect installation can cause wate...

Page 18: ...e heat exchanger clogs When the protection triggers the unit must be accurately cleaned by opening the upper panel and sucking any impu rities present In case of malfunction of the fan repair or replace as required The air conditioner comes with its own power supply cable for connection to the local mains In order to avoid overloads make sure that the electric system s socket voltage and current l...

Page 19: ...19 ...

Page 20: ...20 A2B Accorroni E G s r l Via d Ancona 37 60027 Osimo An Tel 071 723991 r a Fax 071 7133153 web site www accorroni it e mail a2b accorroni it ...