Display Cases / Plug-in
10
www.ggmgastro.com
Always electrically isolate cabinet before carrying out any work that may effect or expose electrical
components or moving parts (eg: fan blades).
8.1.3.Access to fans
For access to fans, lift out decks and remove any shelves or trolleys and fan cowls.
If removing fan baffle assembly, remove screws at top of fan baffle and then lift it out using the lifting rings on
the baffle. Place near the cabinet ensuring there is no strain placed on connecting cables.
8.1.4.Access to drainage outlets
Drainage outlets are located behind the fan baffles.
Cabinet interconnecting drainage lines are located under the drain tray. They can be accessed by removing
deck, dolly or trolley section.
8.1.5.Access to cabinet electrics and controls
For safety sake, when working inside the condensing unit the power supply must be switched off .
8.1.6.Access to probes
The ambient probe and defrost probes are now accessible
9.USE OF CABINET
9.1.Transportation
GGM gastro international its refrigerated cabinets suitable to be carried with forklift fork. It should be
considered to replace the forklift forks into appropriate spaces underneath the cabinet.In addition to protect
cabinets from dust and humidity, they are wrapped with plastic stretch films.
9.2.Shelf mounting
Locate shelves into the slotted stub to the required height.
Note when the shelf is in the sloping format the shelf should be located in the rear cutouts to minimise the
gap between the shelf and the perforated back.
Only use recommended shelf configurations to ensure correct cabinet operation and loading
characteristics.
9.3.Loading of products
Always allow air space between the product and the shelf above in order to maintain cold air circulation and do
not block air grills.
Evaporator
coil
Fans