5.
Power Budget (examples)
The power budget has been estimated based on power consumption measurements of DATA-CUBE³ type 1
at laboratory conditions and on using two
“Duracell Procell MN1300” batteries with a capacity of 39.6Wh.
DATA-CUBE³ type 1, measuring all 3 channels @ 100sps
GPS Cycle
GPS on
GPS on
GPS off
Sum
Runtime
F_TIME
GPS_TI
duration
duration
power
duration
Min
min
min/h
min/h
mW
days
15
5
20
40
147
11.2
15
4
16
44
140
11.8
15
3
12
48
133
12.4
30
5
10
50
129
12.8
30
4
8
52
125
13.2
30
3
6
54
122
13.5
30
2
4
56
118
14.0
59
59
59
0
219
7.5
Current while GPS on: 73mA / 219mW
Current while GPS off: 37mA / 111mW
Battery capacity: 39.6Wh
DATA-CUBE³ type 1, measuring only 1 channel @ 100sps
GPS Cycle
GPS on
GPS on
GPS off
Sum
Runtime
F_TIME
GPS_TI
duration
duration
power
duration
Min
min
min/h
min/h
mW
days
15
5
20
40
114
14.5
15
4
16
44
107
15.4
15
3
12
48
100
16.6
30
5
10
50
96
17.2
30
4
8
52
92
17.9
30
3
6
54
89
18.6
30
2
4
56
85
19.4
59
59
59
0
186
8.9
Current while GPS on: 62mA / 186mW
Current while GPS off: 26mA / 78mW
Battery capacity: 39.6Wh
Please note that the real runtime in the field can vary and is strongly depend on different parameters like
environmental temperature, real capacity and age of batteries. Please see the battery capacity vs. temperature
diagram below to estimate the runtime of the DATA-CUBE³ Type 1
Battery capacity depending on temperature
for “Duracell Procell MN1300” alkaline batteries
Additionally, the values of F_TIME and GPS_TI should not be a multiple of 60. This can lead to undefined