2.3.0 Adjust pre- and main alarm
IMPORTANT:
moving the magnet by 1 mm corresponds to 5 mm touch bar compression movement.
Do not unscrew the pre-alarm screw too much. There is a risk of accidentally damaging the pre-alarm reed-contact.
1 + 2
automatic switch-off
after 3 minutes
Jumper
2 + 3
permanent main alarm
till reset is done
tighten screw,
pre-alarm starts
later
pre-alarm screw
unscrew,
pre-alarm starts
earlier
Main-alarm
sooner later
Release magnet
main-alarm
90
Jumper to set alarm
mode of buzzer
Reed-Contact main-alarm
Reed-Contact pre-alarm