personal protective equipment shall only be used by a person trained and
competent in its safe use.
?
personal protective equipment must not be used by a person with medical
condition that could affect the safety of the equipment user in normal and
emergency use.
?
a rescue plan shall be in place to deal with any emergencies that could arise
!
personal protective equipment must be withdrawn from use immediately
during the work.
when any doubt arise about its condition for safe use and not used again
?
it is forbidden to make any alterations or additions to the equipment without
until confirmed in writing by equipment manufacturer or his representative
the manufacturer's prior written consent.
after carried out the detailed inspection.
?
any repair shall only be carried out by equipment manufacturer or his
?
An anchor device or anchor point for the fall arrest system should
certified representative.
, and the work carried out in such a way, as to minimise both
?
personal protective equipment shall not be used outside its limitations, or for
the potential for falls and potential fall distance. The anchor device/point
any purpose other than that for which it is intended.
should be placed above the user . The shape and construction of the
?
personal protective equipment should be a personal issue item.
anchor device/point shall not allowed to self-acting disconnection of the
?
before use ensure about the compatibility of items of equipment assembled
equipment. t is recommended to use certified and marked structural anchor
I
into a fall arrest system. Periodically check connecting and adjusting of the
point with E
the N795 standard. The m
equipment components to avoid accidental loosening or disconnecting of the
components.
?
it is obligatory verify the free space required beneath the user at the
to
?
it is forbidden to use combinations of items of equipment in which the safe
workplace before each occasion of use the fall arrest system, so that, in the
function of any one item is affected by or interferes with the safe function of
case of a fall, there will be no collision with the ground or other obstacle in
another.
the fall path. The required value of the free space should be taken from
?
before each use of personal protective equipment it is obligatory to carry out
instruction manual of used equipment.
a pre-use check of the equipment, to ensure that it is in a serviceable
?
there are many hazards that may affect the performance of the equipment
condition and operates correctly before it is used.
and corresponding safety precautions that have to be observed during
?
during pre-use check it is necessary to inspect all elements of the equipment
equipment utilization, especially:- trailing or looping of
lanyard over
device
in respect of any damages, excessive wear, corrosion, abrasion, cutting or
sharp edges,- pendulum falls,- extreme temperature,- chemical reagents,-
incorrect acting, especially
retractable fall arresters - cable or webbing
in
electrical conductivity; -
.
retracting and locking function;
?
?
?
it is essential for the safety of the user that if the product is re-sold outside
the original country of destination the reseller shall provide instructions for
use, for maintenance, for periodic examination and for repair in language of
the country in which the product is to be used.
!
device name, serial number, date of purchase and date of first operation,
user name, information concerning repairs and inspections and withdrawal
from use. The Sheet should be completed by the person responsible for
safety equipment in a given place of work. Equipment without a properly
completed Operation Sheet cannot be used.
have
stable structure
inimal strength of any other structural
anchor point should be 12 kN.
dust laden and gre sy environment
a
Regular periodical inspections are essential in terms of equipment condition
and safety of users. Only fully operational equipment is able to provide
safety.The retractable fall arrester must be withdrawn from use and undergo
a complete periodical inspection and maintenance, at least once a year
(after 12 months of use). The inspection must be carried out by the
equipment manufacturer or an authorised representative of the
manufacturer. Such an inspection should check all equipment elements and
functions according valid producer Service Manual. The date of the
subsequent inspection shall be specified after the periodical inspection has
been completed.
The factory where equipment is stored/ used is responsible for keeping the
Operation Sheet for a particular device. The Seet should include at least: the
personal protective equipment must be transported in the package (e.g.: bag
made of moisture-proof textile or foil bag or cases made of steel or plastic)
to protect it against damage or moisture.
?
the equipment can be cleaned without causing adverse effect on its
materials. For textile products use mild detergents for delicate fabrics, wash
by hand or in a machine and rinse in water. Plastic parts can be cleaned
only with water. When the equipment becomes wet, either from being in use
or when due cleaning, it shall be allowed to dry naturally, and shall be kept
away from direct heat. In metallic products some mechanic parts (spring,
pin, hinge, etc.) can be regularly slightly lubricated to ensure better
operation. Other maintenance and cleaning procedures should be adhered
to detailed instructions stated in the
anual of the equipment.
Service M
?
personal protective equipment should be stored loosely packed, in a well-
ventilated place, protected from direct light, ultraviolet degradation, damp
environment, sharp edges, extreme temperatures and corrosive or
aggressive substances.
FUNDAMENTALS RULES OF USING OF A PERSONAL PROTECTIVE EQUIPMENT
STORAGE
T
CRW300 device should
he
be stored in a dry, ventilated, room
temperature and free of
places. Before the
aggresive chemicals
first
usage the device must be stored in manufacturer package.
CLEANING
E
CRW300 casing and the wire rope lanyard
xternal surface of the
can
be cleaned with a
cloth. Do not use any acid or basic solvents.
wet
Cable devices leave to dry in the
state. The cable
unwound
lanyard
can be slightly lubricated with machine oil.
SWITCHING BETWEEN EN360 AND EN1496
Only one of the EN360 or EN1496 functions
and next pull out the crank axle “b” (fig.3-1).
there is neccesity to rescue of the user. In
of the device may be applied at he same
Than, in the consequence of cranking, the
order to change the EN1496 function to
time.To change the function, the operation
device cable is moved up or down, under
EN360 pull out the locking pin “a” and next
described on the fig.3-1 and 3-2 should be
control. The switching from EN360 to
push in the crank axle “b” inwards (fig. 3-2).
done. In particular, to change from EN360 to
EN1496 function may be done especially
Than the device will act as a retractable fall
EN1496 function, pull out the locking pin “a”
when the CR300 have arrested a fall and
arrester.
fig. 3-1
“a”
“b”
fig. 3-2
“a”