Installation Instructions

 

ELEKTROMAT SE 15.48-25,40 
NOT DEFINED

 

Model: 10004112 10006

 

 

 
 
 
 
 
 
 
 
 

 

 

-en- 

 

Status: 25.11.2019

 

 

 

Summary of Contents for ELEKTROMAT SE 15.48-25,40

Page 1: ...Installation Instructions ELEKTROMAT SE 15 48 25 40 NOT DEFINED Model 10004112 10006 en Status 25 11 2019...

Page 2: ...2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales gfa elektromaten co uk www gfa elektromaten co uk...

Page 3: ...h connection 13 9 Emergency manual operation hand chain operator 14 10 Completing commissioning inspection 16 11 Declaration of incorporation Declaration of conformity 18 Symbols Warning Potential inj...

Page 4: ...l be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on e...

Page 5: ...erating current 1 90 A Operating frequency 50 Hz Power factor cos 0 54 Maximum movement per hour 12 h 1 Hand forces 87 N Class of protection IP 65 Limit switch range maximum revolutions of output shaf...

Page 6: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Page 7: ...7 Mounting Eight threads are provided for mounting A key is used to connect to the door shaft Use a key that is at least as long as the hollow shaft BAGAD02003_Z002...

Page 8: ...or manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Th...

Page 9: ...BAGAE02005_Z002 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE02009_Z002 25 Nm Secure the keys versio...

Page 10: ...energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the...

Page 11: ...11 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Page 12: ...12 6 Motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake 7 Alternative motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake...

Page 13: ...13 8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply network...

Page 14: ...y manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453...

Page 15: ...15 Switch on by pulling the red handle Open or close by pulling the chain Switch off by pulling the green handle...

Page 16: ...unts screws locking rings etc are secure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections...

Page 17: ...er to life Lifecycle brake change complete brake unit at Operation with mains supply after 250 000 cycles Operation with Inverter after 1 000 000 cycles In an environment that can affect the coefficie...

Page 18: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fo...

Page 19: ...19...

Page 20: ...20...