Mounting 

Four holes are provided for mounting.  
 

 

 

Summary of Contents for 10003958 10011

Page 1: ...f Installation Instructions ELEKTROMAT FT 80 5 FU 45 00 Model 10003958 10011 en Status 25 11 2021...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Page 3: ...mergency manual operation lever 13 9 Completing commissioning inspection 14 10 Disposal 15 11 Declaration of incorporation Declaration of conformity 16 Symbols Warning Potential injury or danger to li...

Page 4: ...xperience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The s...

Page 5: ...Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if...

Page 6: ...Operating frequency 50 60 Hz Power factor cos 0 47 Safety circuit 24 V Degree of protection IP 65 Temperature range 5 40 60 2 C Operating sound pressure level 70 dB A Output speed OPEN 0 5 5 min 1 Out...

Page 7: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Page 8: ...8 Mounting Four holes are provided for mounting...

Page 9: ...use a lifting device that has a sufficient load carrying capacity Tighten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufa...

Page 10: ...energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the...

Page 11: ...final limit positions OPEN and CLOSE is described in the instructions for the door control The door control must meet Performance Level c Use only door controls that evaluate the limit switch accordi...

Page 12: ...1 Motor X13 Motor plug 7 Limit switch connection S9 Release switch X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage W3 Connection cabl...

Page 13: ...ening or closing doors that do not have electric power supply Operation interrupts the control voltage Electrical operation is no longer possible Warning Injury through improper operation Disconnect t...

Page 14: ...ecure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good ele...

Page 15: ...ose of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough p...

Page 16: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The f...

Page 17: ...17...

Reviews: