background image

 

14 

 

Pos: null /BA_Module/BA_UA  Nothandbetätigung/BAUA000001_M003 @ 24\mod_1511866921360_28.docx @ 1061558 @ 1 @ 1 

 

8

 

Emergency manual operation (emergency hand crank) 

The emergency manual operation is designed for opening or closing the door without power 
supply. Its activation interrupts the control voltage. Electrical operation is no longer possible. 

 

 

Warning – Injuries due to incorrect operation or falling objects! 

 

 

Switch off voltage. 

 

Adopt a secure position. 

 

For drive units with brake, the emergency manual operation must be carried out 
against the closed brake. 

 

 

Warning - Danger of the door dropping! 

 

If you need to apply more than the permissible force of 390N (according to DIN EN 
12604/DIN EN 12453) to move the door by emergency manual operation, this 
indicates a stalling on the drive unit or door. Releasing the stalling may cause the 
door to drop.  

 

Adopt a secure position 

 

For drive units with brake, the emergency manual operation must be carried out 
against the closed brake. 

 

 

Caution – Damage to components! 

 

 

Do not move the door beyond the final limit positions. 

 

 

 

Summary of Contents for 10003900 10011

Page 1: ...eckblatt BAAA000001_M003 17 mod_1444211755814_28 docx 891110 1 Installation Instructions ELEKTROMAT SI 17 60 FU 25 40 Model 10003900 10011 en Status 06 03 2020 Pos null BA_Module BA_Seitenumbruch 0 mo...

Page 2: ...BACA000001_M002 15 mod_1416821436083_28 docx 864410 1 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de Pos null BA_Module BA_Seitenumbru...

Page 3: ...nection 13 8 Emergency manual operation emergency hand crank 14 9 Completion of commissioning testing 16 10 Declaration of incorporation Declaration of conformity 19 Pos null BA_Module BA_Seitenumbruc...

Page 4: ...t of the manufacturer Otherwise the Manufacturer s Declaration shall be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitter...

Page 5: ...h 1 Hand forces 157 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow shaft 20 Braking torque 5 Nm Braking voltage 103 V DC Rectifier type FU Temperature range...

Page 6: ...nsmission elements must not be exceeded even for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800...

Page 7: ...available for version Three elongated holes are provided for version Use at least 2 of these for mounting Always use elongated hole A key is used to connect to the door shaft Use a key that is at lea...

Page 8: ...ufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Versions...

Page 9: ...BAGAE02004_Z002 Version Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE02008_Z002 25 Nm Version Attach...

Page 10: ...Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE02010_Z003 8 8 8 8 75 Nm Versions Secure the keys version only BAGAE02012_Z003 Pos null BA_Modul...

Page 11: ...the cables are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the moto...

Page 12: ...1_M001 2 mod_1303306898342_28 docx 654220 1 1 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel Pos null...

Page 13: ...M1 Motor X13 Motor plug Y1 Brake Pos null BA_Module BA_NA Endschalteranschluss BANA101101_M001 0 mod_1245933330141_28 docx 243304 1 1 7 Limit switch connection S10 Manual operation X12 DES connection...

Page 14: ...dopt a secure position For drive units with brake the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the per...

Page 15: ...e crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361...

Page 16: ...afety brake is triggered to prevent the door from dropping The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling...

Page 17: ...its equipment The manufacturer s specifications must be observed The brake release for doors without counter balancing may only be used in the CLOSE final limit position Warning Injury or danger to li...

Page 18: ...ire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards Ende der Liste f r Textmarke...

Page 19: ...stalled complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signatur...

Page 20: ...20 Ende der Liste f r Textmarke Inhalt1...