General safety information 

 
Specified normal use 
The drive unit is intended for horizontally operating sliding doors. 

 

The drive unit must be protected against moisture and aggressive environmental 
conditions (such as corrosive substances). The drive units are only suitable for indoor use. 
Appropriate protective measures must be taken for outdoor installation. The drive unit is 
not intended for hazardous areas. The values specified in the technical data of the drive 
unit must not be exceeded. The safe operation can only be ensured if used as specified.  

 

 

Target audience of these installation instructions 
These installation instructions are geared towards qualified persons trained in the handling 
of door systems. Expert knowledge, relevant skills and practical experience are what set 
apart qualified persons. They are capable of safely carrying out the tasks involving 
installation, maintenance and modernisation according to the instructions. 
 

 

Safe operation 
The safe operation of the product can only be ensured if it is used as specified. Follow the 
installation instructions. Observe all specifications, especially warnings, when installing the 
product in the overall system. GfA is not liable for damage resulting from non-observance 
of the installation instructions. The resulting overall system must be reassessed for its 
safety in accordance with applicable standards and directives (e.g. CE marking). These 
installation instructions refer only to a part of the overall system and are not sufficient as 
the sole instructions for the overall system. The installer of the system must prepare the 
instructions for the overall system. We recommend entering the danger area of the system 
only when the drive unit is at a standstill. 
 

 

 

Summary of Contents for 10002917 00002

Page 1: ...f Installation Instructions ELEKTROMAT ST 9 24 25 00 Model 10002917 00002 en Status 14 02 2022...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Page 3: ...12 7 Completing commissioning inspection 13 8 Disposal 15 9 Declaration of incorporation Declaration of conformity 16 Symbols Warning Potential injury or danger to life Warning Danger to life from el...

Page 4: ...experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The...

Page 5: ...Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if...

Page 6: ...Temperature range 20 40 60 2 C Operating sound pressure level 70 dB A Maximum output speed OPEN CLOSE for frequency inverter operation 42 42 min 1 Cycles per hour 12 10 4 1 h 1 Max load 9000 N Brakin...

Page 7: ...ven for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole d...

Page 8: ...8 Mounting Four holes are provided for mounting...

Page 9: ...sure to use a lifting device that has a sufficient load carrying capacity Ensure that there is sufficient space around the handwheel for safe operation of the friction clutch Notice Gearbox damage fr...

Page 10: ...ing Potential injury or danger to life Disconnect the electric supply to set the friction clutch The friction clutch provides overload protection It is tightened finger tight at the factory Turning to...

Page 11: ...re de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Connect the motor cables and...

Page 12: ...12 5 Motor connection G1 Half wave rectifier M1 Motor Y1 Magnetic brake 6 Limit switch connection F10 Thermal contact...

Page 13: ...ted Protect the output shaft permanently against corrosion Mounting Check that all connection elements consoles torque mounts screws locking rings etc are secure and in proper condition Electrical wir...

Page 14: ...t be observed In an environment that can affect the coefficient of friction of the brake pad atmosphere with oil solvents detergents etc class of protection IP65i must be adopted Note Engage a qualifi...

Page 15: ...se of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough po...

Page 16: ...omplies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fol...

Page 17: ...17...

Reviews: